Manhattan · Block 298 · Lot 7504 · 10002

30 Orchard Street

11 floors · 9 apartments · 12,569 sq ft · built 1979 · class RM · owner of record: Unavailable Owner

8open violations
$3,650ECB/OATH penalties owed
0HPD class C (immediately hazardous)
60dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 60 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 76 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 304 days
Registered through 2027-09-01
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $80,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2028
in 477 days
No Cycle 10 report on record yet
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 791 days
Next cycle year 2028

Open violations

ECB / OATH (4) · $3,650 owed
IssuedViolationHearingBalance
Jul 9, 2026Unknown CLASS - 2
AT TIME OF INSPECTION OF A 12 STORIES BUILDING UNDER FACADE REPAIR I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE # 1 USED AS DEBRIS STORAGE AND WORK STATION AS CONTRARY TO 3307.6.4.2.2 AND NON CONFORMANCE TO SI
#39556410J
Sep 17, 2026
ADMIT/IN-VIO
$0
Apr 20, 2026Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #914555. REMEDY: FILE ACCEPTABLE REPORT.
#37036678Z
Dec 24, 2026
PENDING
$1,250
Aug 20, 2025Construction CLASS - 2
FAILURE TO COMPLY WITH BUILDING CODES OF SIDEWALK SHED SECTIONS. NOTED MUDSILLS ROTTEN AND SHIFT IT UNDER THE VERTICAL MEMBERS, HORIZONTAL BRACES UNDER SHED LESS THAN 8 FEET IN HEIGHTS, BROKEN PARAPET WALL PANE
#39543880L
Oct 30, 2025
IN VIOLATION
$2,400
Jan 16, 2024Signs CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE AMENDED CYCLE 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.4 FOR CONTROL #914555. REMEDY: FILE ACCEPTABLE REPORT.
#37026691Y
Nov 21, 2024
DEFAULT
$0
DOB (3)
IssuedViolationStatus
Feb 16, 2024CONSTRUCTION
.PARTIAL VACATE ORDER UNSAFE NOTIFICATION (FISP)FILED AS OBSRVATION OF SEVERLY CRACKED & BULGING PANELS LOCATED AT THE EAST,WEST&SOUTH ELEV THESE CONDITIONS HAVE THERFORE MADE THE ENTIRE FRONT TERRACE AT WEST ELEV.&COURTYARD@EAST ELEV.UNABLE TO BE OCCUPIED.VACATE FRONT TERRACE@ WEST ELEV.&REAR COURT
#FA0301BS
DOB VIOLATION - ACTIVE
Dec 18, 2023HAZARDOUS CONDITION (FACADE)
CYCLE 9B UNSAFE REPORT FILED
#911353
DOB VIOLATION - ACTIVE
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#01010
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Dec 18, 2023Facades FISPHAZ
CYCLE 9B UNSAFE REPORT FILED
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Jul 30, 2026DOB SafetyAEUHAZ: Closed
Jul 9, 2026ECBUnknown: AT TIME OF INSPECTION OF A 12 STORIES BUILDING UNDER FACADE REPAIR I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE # 1 USED AS DEBRIS STORAGE AND WORK STATION AS CONTRARY TO 3307.6.4.2.2 AND NON CONFORMANCE TO SIOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 1, 2026, 11:30 PM ET. BBL 1002987504.