Queens · Block 578 · Lot 40 · 11102

30-78 29 Street

7 floors · 27 apartments · 22,960 sq ft · built 2024 · class D1 · owner of record: 3078 Llc

2open violations
$24,275ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 62 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 78 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 479 days
No Cycle 10 report on record yet
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 793 days
Next cycle year 2028

Open violations

ECB / OATH (12) · $24,275 owed
IssuedViolationHearingBalance
Apr 30, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OF A (7) STORY NEW BUILDING ACTIVE JOB SITE, WORKERS WERE OBSERVED PERFORMING WORK AT THE ROOF LEVEL. NO GUARDRAIL SYSTEM WAS PROVIDED AT EXPOSURE 4, WITH WORKERS OPERATING AT THE EDGE
#39553650P
Feb 2, 2027
$2,500
Apr 30, 2026Construction CLASS - 1
AC 28-111 (7) STORY ACTIVE JOB SITE, ONGOING CONSTRUCTION WAS OBSERVED. APARTMENTS 4C AND 4A CONTAINED FURNITURE, INCLUDING COUCHES, TABLES, AND CAFE SETS. THE FIRST FLOOR WAS EQUIPPED AS A FULL GYM. NO CERTIFI
#39553649H
Feb 2, 2027
$2,500
Apr 15, 2026Unknown CLASS - 2
ACTIVE 7STORY NB, OBSERVED SUPPORTED SCAFFOLD AT EXPO3 NOT MAINTAINED OR BUILT PER PLANS OR MANUFACTURERS SPECS BC 3301.6. NOTED DIFFERENT TYPES OF SCAFFOLD FRAMES USED ON SCAFFOLD. SF PLANS PAGE EQ-004 REFLECT
#39553038Z
Feb 2, 2027
$2,500
Apr 15, 2026Unknown CLASS - 2
ACTIVE 7STORY NB, OBSERVED FIRE EXTINGUISHERS NOT MAINTAINED NOR READILY AVAILABLE AS PER BC IN CASE OF EMERGENCY ON SEVERAL FLOORS. EXPIRED FIRE EXTINGUISHER INSPECTION TAGS WERE SEEN ON FLOORS EXPIRED SINCE 2
#39553041J
Feb 2, 2027
$625
Apr 14, 2026Construction CLASS - 2
RESPONDING TO A COMPLAINT OBSERVED: SIDEWALK SHED INSTALLED AT EXPO# 1. NO UNDERSIDE LIGHTING INOPERABLE LIGHT BULBS, FAILURE TO MAINTAIN AS PER CODE 3307.6.4.8 BECOME AN UNSAFE HAZARDOUS CONDITION AND DANGEROU
#39552944X
Feb 2, 2027
PENDING
$2,400
Feb 27, 2026Construction CLASS - 1
DURING INSPECTION OF A 7 STORY BUILDING I OBSERVED SEVERAL PLYWOOD BOARDS ON THE SIDEWALK, SAND BAGS, AND BARRIERS IN THE PEDESTRIAN WALKWAY. THE HOUSEKEEPING WAS INADEQUATE AND CREATED A HAZARD (TRIP AND FALLS
#39551024Z
Nov 17, 2026
$2,500
Feb 27, 2026Unknown CLASS - 2
BC3307.4 WARNING SIGNS: DURING INSPECTION OF A 7 STORY BUILDING I OBSERVED WHILE WALKING UNDER THE SIDEWALK SHED THAT THERE WAS A MAKESHIFT CORNER, THAT WAS NOT CLEARLY VISIBLE. NO MIRROR WAS POSITIONED OVER HE
#39551023R
Nov 17, 2026
$2,500
Feb 7, 2026Unknown CLASS - 2
NEW 7STORY BUILDING. OBSERVED ACTIVE SITE UNDER AHV PERMIT Q9934995. UPON EXTERIOR INSPECTION NOTED: DEBRIS CONTAINER NOT FULLY PROTECT CHAIN LINK FENCE NOT COVERING ENTIRE AREA CREATING HAZARDS FOR PEDESTRIANS
#39550052L
Nov 24, 2026
$2,500
Aug 9, 2025Unknown CLASS - 2
NEW 7 STORY BUILDING OBSERVED: SITE CLOSED , ON EXPOSURE 4 NOTED ELEVATED SUSPENDED SCAFFOLD CONTRARY TO BUILDING CODE BC3314.3.3.10
#39543474X
Dec 22, 2026
$2,500
Aug 9, 2025Construction CLASS - 2
NEW 7 STORY BUILDING OBSERVED: SITE CLOSED ON EXPOSURE 1 INSTALLED DEBRIS CHUTE CONTRARY TO DRAWINGS . CONTRACTOR FAILURE TO PROVIDE SPLASH GUARD AT BOTTOM OF DEBRIS CHUTE AS PER Q001.00STOP AL USE OF DREBIRS
#39543472M
Dec 22, 2026
$1,250
Jul 28, 2025Unknown CLASS - 2
BC 3301.13.11 REPORTING OF INCIDENT: I RESPONDED TO A COMPLAINT ABOUT A WORKER WHO FELL FROM A LADDER AND BROKE THEIR ARM ON JULY 25, 2025 THE WORKER WAS TAKEN TO THE HOSPITAL. THE SUPERINTENDENT FAILED TO NOTI
#39542977N
Jan 12, 2027
$2,500
Dec 24, 2024Unknown CLASS - 2
3314.3.4-ACTIVE 7 STORIES BUILDING OBSERVED SUPPORTED PIPE SCAFFOLD W/COUNTERWEIGHTS ON SHED, NO LOADS IMPOSED LETTER NOR PLANS FOR MAKE-SHIFT SCAFFOLD W/ WEIGHTS.FAIL TO HAVE LOAD LETTER & APPROVED PLANS CREAT
#39535337J
Mar 4, 2025
IN VIOLATION
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 6:03 PM ET. BBL 4005780040.