Queens · Block 239 · Lot 6 · 11101

30-25 Queens Boulevard

46 floors · 560 apartments · 510,543 sq ft · built 2025 · class D6 · owner of record: 30-25 Queens Blvd Tenant Llc

6open violations
$51,280ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 121 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 510,543 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 190 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 190 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 800 days
Next cycle year 2028
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 239). Agency page

Dec 31, 2029
in 1165 days
Next due 2029

Open violations

ECB / OATH (12) · $51,280 owed
IssuedViolationHearingBalance
Oct 16, 2026Construction CLASS - 1
AN INCIDENT WERE A WORKER WAS RELOCATING LARGE BINS FROM ONE AREA TO ANOTHER USING A POWER JACK THE WORKER COLLIDED WITH METAL SHORING PINNING THEIR RIGHT PINKY BETWEEN THE MACHINE & SHORING & PARTIALLY SEVERIN
#39560671J
Dec 22, 2026
PENDING
$12,500
Sep 29, 2026Unknown CLASS - 1
OBSERVED JERSEY BARRIERS, TEMPORARY WALKWAY ON STREET AND FENCE ON THE SIDEWALK AT EXP#1, UPON REQUEST FOR DOT PERMITS NONE WERE PROVIDED. STREET OPERATIONS NEAR A BUSY AREA WITHOUT DOT PERMITS CREATES INJURY H
#39559972P
Dec 8, 2026
PENDING
$1,250
Sep 2, 2026Construction CLASS - 1
RESPONDING TO AN INCIDENT WHERE A RESHORE FELL FROM THE 16TH FLOOR TO THE 2ND FLOOR SETBACK. INSPECTION REVEALED THAT THE INCIDENT OCCURRED AT APPROXIMATELY. 10:30 AM AND WAS NOT REPORT THE DEPARTMENT UNTIL APP
#39558702K
Nov 10, 2026
ADMIT/IN-VIO
$0
Sep 2, 2026Construction CLASS - 1
RESPONDING TO AN INCIDENT WHERE A RESHORE FELL FROM THE 16TH FLOOR TO THE 2ND FLOOR SETBACK. INSPECTION REVEALED THAT THE RESHORE WAS NOT SECURED AS REQUIRED TO PREVENT FALLING OFF THE BUILDING AS PER 3305.3.6.
#39558701Z
Nov 10, 2026
ADMIT/IN-VIO
$0
Sep 2, 2026Construction CLASS - 1
RESPONDING TO AN INCIDENT WHERE A RESHORE FELL FROM THE 16TH FLOOR TO THE 2ND FLOOR SETBACK. INSPECTION REVEALED THAT THE RESHORE WAS NOT SECURED AS REQUIRED TO PREVENT FALLING OFF THE BUILDING AS PER 3305.3.6.
#39558699Z
Nov 10, 2026
$10,000
Sep 2, 2026Construction CLASS - 1
RESPONDING TO AN INCIDENT WHERE A RESHORE FELL FROM THE 16TH FLOOR TO THE 2ND FLOOR SETBACK. INSPECTION REVEALED THAT THE INCIDENT OCCURRED AT APPROXIMATELY. 10:30 AM AND WAS NOT REPORT THE DEPARTMENT UNTIL APP
#39558700R
Nov 10, 2026
$5,000
Aug 20, 2026Unknown CLASS - 1
BC3301.8.2 USE&TAMPERING PROHIBITED.IN RESPONSE TO WORKER INJURED ON SITE DURING HOISTING OPERATIONS@2ND FL REAR TERRACE.PER SITE PERSONNEL,WHILE LOWERING POWER TROWEL,CONTROL WAS LOST W/USE OF TAG LINE(1RCNY33
#39558175H
Oct 27, 2026
$5,000
Aug 20, 2026Construction CLASS - 1
IN RESPONSE TO WORKER INJURED DURING LOWERING POWER TROWEL W/ CRANE@2ND FL REAR TERRACE,I OBSERVE AREA WHERE INJURY OCCURRED PER SITE PERSONNEL ENCUMBERED W/SITES EQUIPMENT&MATERIAL FAILING TO ENSURE SAFE&CLEAR
#39558176J
Oct 27, 2026
$2,500
Jul 16, 2026Construction CLASS - 1
BC 3305.3.6.1.2 FAILURE TO SECURE RESHORES IN PROXIMITY TO UNCLOSED PERIMETER.AS NOTED AT THE TIME OF INSPECTION OF AN ACTIVE PROPOSED 50 STORY NEW BUILDING,CONCRETE PLACEMENT ON 7TH FLOOR.I OBSERVED UNSECURED
#35729994J
Nov 17, 2026
$2,500
Feb 3, 2026Unknown CLASS - 1
BC 3301.2 WORKER WALKED APPROX. 100FT CARRYING A 16FT PIECE OF LUMBER BY HIMSELF ON UNEVEN SLOPED GROUND WITH LOOSE SOIL, ROCKS, & DEBRIS AND TRIPPED OVER A 2X4 RESULTING IN BEING TRANSPORTED BY EMT TO ELMHURST
#39549890M
Mar 25, 2027
DEFAULT
$5,030
May 29, 2025Construction CLASS - 2
AT TIME OF INSPECTION, CONSTRUCTION FENCE WAS MISSING AT EXPOSURE 3. PER BC 3304.4.3 AND 3307.7, FENCING IS REQUIRED TO PROTECT THE PUBLIC FROM OPEN EXCAVATION AND SITE HAZARDS. LACK OF PROPER FENCING POSES RIS
#39540760N
Jan 28, 2027
DEFAULT
$2,500
Jan 24, 2025Unknown CLASS - 2
BC3307.2.1 OBSTRUCTION OF STREETS, INCLUDING BICYCLE LANES AND SIDEWALKS.NO DOT PERMIT. PERMITTED SITE IN EXCAVATION PHASE OBSERVE JOB FENCE TO CURB LINE @EXP#1(NORTHERN BLVD) WITH JERSEY BARRIER ON STREET&SECT
#39536262Z
Nov 24, 2026
$5,000
DOB (1)
IssuedViolationStatus
Mar 10, 2008CONSTRUCTION

#0101MT
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Sep 25, 2026AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 16, 2026ECBConstruction: AN INCIDENT WERE A WORKER WAS RELOCATING LARGE BINS FROM ONE AREA TO ANOTHER USING A POWER JACK THE WORKER COLLIDED WITH METAL SHORING PINNING THEIR RIGHT PINKY BETWEEN THE MACHINE & SHORING & PARTIALLY SEVERINOpen
Sep 29, 2026ECBUnknown: OBSERVED JERSEY BARRIERS, TEMPORARY WALKWAY ON STREET AND FENCE ON THE SIDEWALK AT EXP#1, UPON REQUEST FOR DOT PERMITS NONE WERE PROVIDED. STREET OPERATIONS NEAR A BUSY AREA WITHOUT DOT PERMITS CREATES INJURY HOpen
Sep 25, 2026DOB SafetyAEUHAZ: Open
Sep 25, 2026DOB SafetyAEUHAZ: Closed
Sep 2, 2026ECBConstruction: RESPONDING TO AN INCIDENT WHERE A RESHORE FELL FROM THE 16TH FLOOR TO THE 2ND FLOOR SETBACK. INSPECTION REVEALED THAT THE INCIDENT OCCURRED AT APPROXIMATELY. 10:30 AM AND WAS NOT REPORT THE DEPARTMENT UNTIL APPOpen
Sep 2, 2026ECBConstruction: RESPONDING TO AN INCIDENT WHERE A RESHORE FELL FROM THE 16TH FLOOR TO THE 2ND FLOOR SETBACK. INSPECTION REVEALED THAT THE RESHORE WAS NOT SECURED AS REQUIRED TO PREVENT FALLING OFF THE BUILDING AS PER 3305.3.6.Open
Sep 2, 2026ECBConstruction: RESPONDING TO AN INCIDENT WHERE A RESHORE FELL FROM THE 16TH FLOOR TO THE 2ND FLOOR SETBACK. INSPECTION REVEALED THAT THE RESHORE WAS NOT SECURED AS REQUIRED TO PREVENT FALLING OFF THE BUILDING AS PER 3305.3.6.Closed
Sep 2, 2026ECBConstruction: RESPONDING TO AN INCIDENT WHERE A RESHORE FELL FROM THE 16TH FLOOR TO THE 2ND FLOOR SETBACK. INSPECTION REVEALED THAT THE INCIDENT OCCURRED AT APPROXIMATELY. 10:30 AM AND WAS NOT REPORT THE DEPARTMENT UNTIL APPClosed
Aug 20, 2026ECBCranes and Derricks: AFTER INSPECTION, IT WAS DISCOVERED THAT SIGNALMAN JAMAR WILLIAMS WAS STRUCK DURING HOISTING OPERATIONS OF TOWER CRANE CD 5170 CN 64325. A POWER FLOAT WAS BEING LOWERED BY THE TC TO THE 2ND-FLOOR TERRACE WHEN TClosed
Aug 20, 2026ECBUnknown: BC3301.8.2 USE&TAMPERING PROHIBITED.IN RESPONSE TO WORKER INJURED ON SITE DURING HOISTING OPERATIONS@2ND FL REAR TERRACE.PER SITE PERSONNEL,WHILE LOWERING POWER TROWEL,CONTROL WAS LOST W/USE OF TAG LINE(1RCNY33Closed
Aug 20, 2026ECBConstruction: IN RESPONSE TO WORKER INJURED DURING LOWERING POWER TROWEL W/ CRANE@2ND FL REAR TERRACE,I OBSERVE AREA WHERE INJURY OCCURRED PER SITE PERSONNEL ENCUMBERED W/SITES EQUIPMENT&MATERIAL FAILING TO ENSURE SAFE&CLEARClosed
Aug 19, 2026DOB SafetyAEUHAZ: Closed
Jul 16, 2026ECBConstruction: BC 3305.3.6.1.2 FAILURE TO SECURE RESHORES IN PROXIMITY TO UNCLOSED PERIMETER.AS NOTED AT THE TIME OF INSPECTION OF AN ACTIVE PROPOSED 50 STORY NEW BUILDING,CONCRETE PLACEMENT ON 7TH FLOOR.I OBSERVED UNSECUREDClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 11:44 AM ET. BBL 4002390006.