5 floors · 10 apartments · 7,732 sq ft · built 2017 · class D1 · owner of record: Takoor, Tajuddin Gul
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 62 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 78 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 306 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 793 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 17, 2021 | Unknown CLASS - 2 CONST SUPER FAILED TO PERFORM DUTIES PER CODE.NOTE:FOLLOWING VIOLATINGCONDITIONS OBSERVED@ACTIVE JOBSITE:(1)FAILURE TO DESIGNATE COMPETENT PERSON FOR SITE WHICH SUPER IS RESPONSIBLE.SPOKE W/PLUMBERS&MASON&THEY #35589937L | Sep 27, 2022 IN VIOLATION | $5,000 |
| Aug 23, 2021 | Construction CLASS - 1 3301.7.2 FIRE EXTINGUISHERS.AT TIME OF INSPECTION OF A 5 STORY NEW BUILDING,I OBSERVED FIRE EXTINGUISHERS ON THE GROUND AND NOT CHECKED MONTHLY.REMEDY:PROVIDE/MAINTAIN FIRE EXTINGUISHERS AS PER CODE. #35587845P | Nov 23, 2021 IN VIOLATION | $1,875 |
| Jun 11, 2021 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.COMPLAINT#4798363 DISPOSTION DATE 12/31/2019 #4 AND 9/4/2020 #5.AT TIME OF INSPECTION OF ACTIVE PERMIT 5 STORY NEW BUILDING UNDER PARTIAL STOP WORK #35574426H | Nov 16, 2021 IN VIOLATION | $3,750 |
| Dec 9, 2019 | Construction CLASS - 1 FAILURE TO INSTITUTE MAINTAIN SAFETY EQUIPMENT MEASUE INADEQUTE GUARDRAILS.NOTE:AT TIME OF MY INSPECTION OF A 5 STORY BUILDING AT ROOF LEVELUNDER CONSTRUCTION WORK IN PROGRESS.I OBSERVED THAT THE INADEQUATE GUA #35456231K | Oct 13, 2020 IN VIOLATION | $2,500 |
| Dec 9, 2019 | Construction CLASS - 1 BC3301.2/HOLES NOT COVERED;NOTE:AT TIME OF MY INSPECTION OBSERVED ACTIVE JOBSITE HOLES ARE FOUND ON FLOORS 2ND THROUGH 5TH FLOORS ON THE SLAB NOT COVERED AS REQUIRED SOME LOCATION COVERED ADQEQUATE WAS NO SECUR #35456232M | Oct 13, 2020 IN VIOLATION | $2,500 |
| Sep 4, 2019 | Construction CLASS - 1 UNSAFE STORAGE AT MATERIALS DURING CONSTRUCTION AT THE TIME OF MY INSPECTION OF A 5 STY BLDG @ THE 5TH STY,I OBSERVED MATERIALS & DEBRIS STORED NEAR THE EDGE OF THE BLDG AT THE PERIMETERS EXP#1,2&3 THROUGHOUT #35453483N | Feb 11, 2020 IN VIOLATION | $2,500 |
| Sep 4, 2019 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED DOCUMENTS AT THE TIME OF MY INSPECTION OF A PROPOSED 5 STY NEW BLDG,I OBSERVED CANTILEVER PLATFORMS INSTALLED AT 5 STY LEVEL. UPON MY REQUEST FOR THE DESIGN DRAWINGS IT WAS #35453482L | Feb 11, 2020 IN VIOLATION | $2,500 |
| Sep 4, 2019 | Construction CLASS - 2 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION. AT THE TIME OF MY INSPECTION OF A 5TH STY NEW BLDG AT 5THSTY,I OBSERVED HOLES IN THE SLAB THAT WAS UNSAFELY(COVERED)NOT CLEATED #35453484P | Feb 11, 2020 IN VIOLATION | $5,000 |
| May 23, 2019 | Site Safety CLASS - 1 INADEQUATE LOG BOOK. AT THE TIME OF INSPECTION OF A 5 STY NB,UPON REVIEWING THE LOG BOOK,NONE OF THE VIOLATING CONDITIONS ARE LISTED THE ROOF PROTECTION,OOVERHEAD PROTECTION,WORKING PLATFORM INADEQUATE FALSE #35419311H | Sep 6, 2019 IN VIOLATION | $10,000 |
| May 23, 2019 | Construction CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT THE TIME OF MY INSPECTION OF A 5 STY NB AT 4TH FL. I OBSERVED THE WORKER ON A MAKE SHIFT SCAFFOLD APPROX 25FEET ABOVE 3RD FLOO #35419308R | Sep 6, 2019 IN VIOLATION | $10,000 |
| May 23, 2019 | Construction CLASS - 1 WORK W/O A PERMIT. AT THE TIME OF INSPECTION I OBSERVED PLATFORMS ON THE 3RD FL ECXP#2&4,NOT 25 FEET FROM ADJOINING PROPERTIES. OBSERRVED WORKERS ON EXP#2 SIDE WORKING ON PLATFORM WITHIN 20 FEET OF PROPERTY. #35419316R | Sep 6, 2019 IN VIOLATION | $2,500 |
| May 23, 2019 | Construction CLASS - 1 WORK CONTRARY TO CONSTRUCTION DOCUMENTS. AT THE TIME OF MY INSPECTION I OBSERVED OVERHEAD PROTECTION ON EXP#2&4 SIDES DOES NOT COMPLY TO PLANS & DRAWINGS ON SITE. HAVE PE PROVIDE DETAIL DOCUMENTS OF PROPER OVER #35419317Z | Sep 6, 2019 IN VIOLATION | $2,500 |
| May 23, 2019 | Construction CLASS - 1 SEC. 3305.3.2 NO (SITE)SPECIFIC FORMWORK DESIGN. AT THE TIME OF MY INSPECTION OF 5 STY NB I OBSERVED PLYWOOD FORMS ATTACHED TO(DOKA)FORMS WHICH DID NOT COMPLY W/PLANS/DOCUMENTS. REMEDY: STOP ALL EXTERIOR WORK #35419315P | Sep 17, 2019 IN VIOLATION | $2,500 |
| May 23, 2019 | Construction CLASS - 1 SEC. 3309.12 ADJOINING EQUIPMENT & SPACES PROTECTION YARDS/(CHIMNEY). AT THE TIME OF MY INSPECTION OF 5 STY NB AT 4TH FL. THE CHIMNEY & AIR VENTS ARE NOT PROTECTED AT BOTH EXP#2 & 4. REMEDY: STOP ALL EXTERIOR #35419313L | Sep 6, 2019 IN VIOLATION | $2,500 |
| May 23, 2019 | Construction CLASS - 1 SEC. 3309.10 ROOF PROTECTION OF ADJOINING PROPERTY. AT THE TIME OF MY INSPECTION OF A 5 STY NB AT 4TH FL,I OBSERVED A MAKE SHIFT ROOF PROTECTION AT EXP#2 BUILT FROM PLYWOOD HANGING FROM CABLES,TIES TO THE CONCR #35419309Z | Aug 20, 2019 IN VIOLATION | $3,530 |
| May 23, 2019 | Site Safety CLASS - 1 DUTIES OF CONSTRUCTION SUPERINTENDENT. AT THE TIME OF MY INSPECTION OF5 STY NB AT 4TH FL THE FOLLOWING CONDITIONS ARE A DIRECT NEGLECT OF THE CONSTRUCTION SUPERINTENDENT. 1)HAVING A WORKER OUTSIDE ON A MAKESHIF #35419310X | Sep 6, 2019 IN VIOLATION | $10,000 |
| May 23, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING. AT THE TIME OF MY INSPECTION OF 5 STY NB AT 4TH FL I OBSERVED THE 3RD FL HAS SCATTERED MATERIAL,CONCRETE FORMS REBAR,2X4,PLYWOOD(RAMANDEY)TOOSED ALL OVER THE FLOOR AND #35419314N | Sep 6, 2019 IN VIOLATION | $2,500 |
| Feb 28, 2019 | Construction CLASS - 2 FAILURE TO PERFORM SPECIAL INSPECTIONS AND VERIFICATIONS FOR CONCRETE CONSTRUCTION AS REQUIRED BY SECTION AND TABLE 1714.4. AS NOTED: AT TIME OF INSPECITON AT THE CONSTRUCTION SITE, IT WAS OBSERVED THAT: 1) #35254712X | Aug 6, 2019 DEFAULT | $5,000 |
| Jan 25, 2019 | Construction CLASS - 2 3301.7;FAILURE TO PROVIDE P.E APPROVED REPAIR DETAILS SHEARWALL,SLAB ,BEAM,AS NOTED:AT TIME OF INSPECTION ON A ACTIVE CONSTRUCTION SITE.OBSERVED AT FLOOR # ,EXPOSURE #2,SHEARWALL WITH WHOLE AND CONCRETE MISSING #35369074K | Jul 23, 2019 IN VIOLATION | $625 |
| Jul 17, 2018 | Construction CLASS - 2 SEC. 3301.2 FAILURE TO MAINTAIN NO OHP OBSERVED ACTIVE,NO OVERHEAD PROTECTION IN PLACE FOR SITE ENTRANCE AT EXP#1&3 TO PROTECT PERSONS FROM FALLING OBJECTS FROM ABOVE,DEBRIS/BLDG MATERIALS/TOOLS. REMEDY: PROVID #35342997Z | Dec 4, 2018 DEFAULT | $3,125 |
| Jul 17, 2018 | Construction CLASS - 1 HOUSEKEEPING. HOUSEKEEPING INADEQUATE AT 1ST & REAR YARD CONSISTING OFDISCARDED DEBRIS/MATERIALS CREATING A TRIP & FALL HAZARD. STOP ALL WORK AT 1ST STY & REAR YARD EXP#3. REMEDY: PROVIDE ADEQUATE HOUSEKEEPING #35342998K | Dec 4, 2018 DEFAULT | $6,250 |
| Jul 17, 2018 | Construction CLASS - 1 BC3309.1 NO PROTECTION FOR ADJACENT PROPERTY. ACTIVE CONSTRUCTION SITE 5 STY NB, CURRENTLY @ 3RD STY WORKING DECK. NO PROTECTION IN PLACE FOR ADJACENT PROPERTY AT EXP #2 FRONT & REAR AND NO PROTECTION IN PLACE #35342999M | Dec 4, 2018 DEFAULT | $6,250 |
| Jul 17, 2018 | Construction CLASS - 1 NO STAMPED APPROVED PLANS. NO PLANS ON SITE FOR CONCRETE FORM WORK,ON 2ND FL AT EXP#4 ALSO NO DESIGN FORM WORK DETAIL FOR EXTERIOR FORM WORK AT EXP#4 BLDG FRONT,FORM WORK RESTING ON REBAR. STOP ALL CONCRETE #35342996R | Dec 4, 2018 DEFAULT | $6,250 |
| Jul 5, 2018 | Construction CLASS - 1 SEC. 3301.2 FAILURE TO MAINTAIN(REBAR CAPS)AT TIME OF INSPECTION OF NEW 5 STY BLDG ACTIVE JOBSITE I OBSERVED UNCAPPED REBARS AT EXP#2&3 AT 1ST STY THIS CONDITION CREATES A HAZARD OF IMPLEMENT IF WORKERS OR PERS #35326985L | Dec 4, 2018 DEFAULT | $6,250 |
| Jul 5, 2018 | Construction CLASS - 1 HOUSEKEEPING. AT TIME OF INSPECTION OF NEW 5 STY BLDG ACTIVE JOBSITE IOBSERVED LARGE PILES OF WOOD & CONSTRUCTION MATERIAL PILED HIGHER THEN3FEET @ EXP#3. THIS CONDITION CREATE A POTENTIAL FIRE HAZARD ALSO A #35326984J | Dec 4, 2018 DEFAULT | $6,250 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)