20 floors · 462 apartments · 449,000 sq ft · built 1975 · class D3 · owner of record: Alizio, Anthony
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 56 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 56 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 72 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 449,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 177 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 177 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 300 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 421 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 15945). Agency page | Dec 31, 2035 in 3343 days | Next due 2035 |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-29 (Pre-Filing-Pending Payment). Agency page | On file | 2026 reports accepted |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $412,500 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: SAFE (2025-11-06) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 24, 2026 | Construction CLASS - 2 FACADE WORK 20 STORY BUILDING. OBSERVED MOTORIZED SUSPENDED SCAFFOLD USING C-HOOKS, UPON REQUEST FOR THE ANNUAL MOTOR INSPECTION REPORT THE ONE PROVIDED WAS PERFORMED AT 7/21/2025 AND WHEN REQUEST FOR MANUFACT #39559581H | Dec 1, 2026 PENDING | $1,250 |
| Sep 24, 2026 | Construction CLASS - 2 FACADE WORK 20 STORY BUILDING. OBSERVED C-HOOK SUSPENDED SCAFFOLDS WITHOUT BEARING BLOCKING SUPPORT AT THE FACADE'S PARAPET POINT OF CONTACTCONTRARY TO DOCUMENTS PROVIDED AND AS PER 3314.10.12. NO BEARING BLOCK #39559580X | Dec 1, 2026 PENDING | $1,250 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 30, 2026 | A | Apt 17D · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLACE AT FLOOR OF METAL PIPE AT CLOSET AT EAST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 17D, 17th STORY, 5th APARTMENT FROM SOUTH AT WEST | Feb 2, 2027 |
| Oct 30, 2026 | A | Apt 17D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 17D, 17th STORY, 5th APARTMENT FROM SOUTH AT WEST | Feb 2, 2027 |
| Sep 25, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT EAST WALL, WEST WALL AND CEILING AT PUBLIC HALL, 10th STORY | Dec 29, 2026 |
| Aug 26, 2026 | A | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY COVER AT ALL ELECTRICAL OUTLETS AT PUBLIC HALL, 1st STORY, SECTION ''333'' | Nov 29, 2026 |
| Aug 26, 2026 | A | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY COVER AT ALL ELECTRICAL OUTLETS AT PUBLIC HALL, 4th STORY, SECTION ''333'' | Nov 29, 2026 |
| Aug 26, 2026 | C | Apt 8M · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 8M, 8th STORY, 3rd APARTMENT FROM NORTH AT EAST | Sep 21, 2026 |
| Aug 12, 2026 | A | Apt 6B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 15, 2026 |
| Aug 12, 2026 | A | Apt 6B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 15, 2026 |
| May 22, 2026 | C | Apt APT5A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT APT5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 17, 2026 |
| Mar 13, 2026 | B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT BOILER AT BOILER ROOM | Apr 17, 2026 |
| Feb 17, 2026 | A | Apt 2C · § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WASHBASIN CABINET IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 23, 2026 |
| Dec 18, 2025 | B | Apt 5D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET NORTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 5D, 5th STORY, 5th APARTMENT FROM SOUTH AT WEST , SECTION ''A-D'', AT NORTH | Jan 22, 2026 |
| Dec 18, 2025 | B | Apt 5D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 5D, 5th STORY, 5th APARTMENT FROM SOUTH AT WEST , SECTION ''A-D'', AT NORTH | Jan 22, 2026 |
| Oct 10, 2025 | B | Apt 10B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 14, 2025 |
| Oct 10, 2025 | B | Apt 10B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 14, 2025 |
| Oct 10, 2025 | C | Apt 7M · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 7M, 7th STORY, 4th APARTMENT FROM SOUTH AT WEST | Nov 5, 2025 |
| Oct 10, 2025 | B | Apt 10B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 14, 2025 |
| Oct 10, 2025 | A | Apt 10B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 13, 2026 |
| Oct 10, 2025 | B | Apt 10B · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE COUNTERTOP IN THE KITCHEN LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 14, 2025 |
| Sep 2, 2025 | B | Apt 10B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL.LESS THEN 10 SQ.FT. IN WEST WALL CLOSET. IN THE PRIVATE HALLWAY LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17860989 ISSUED 30-APR-25 HAS BEEN UPGRADED TO CLASS B | Oct 7, 2025 |
| May 5, 2025 | B | Apt 10B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILE FLOOR AT WEST WALL CLOSET. IN THE PRIVATE HALLWAY LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 9, 2025 |
| May 5, 2025 | B | Apt 10B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL. IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 9, 2025 |
| May 5, 2025 | B | Apt 10B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN WEET WALL CLOSET. IN THE PRIVATE HALLWAY LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 9, 2025 |
| May 2, 2025 | C | Apt 10B · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST | May 16, 2025 |
| May 2, 2025 | B | Apt 10B · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB. IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 10B, 10th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 6, 2025 |
| Feb 13, 2025 | C | Apt 5M · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM NORTH AT EAST | Feb 13, 2025 |
| Oct 17, 2024 | C | Apt 17H · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 17H, 17th STORY, 6th APARTMENT FROM NORTH AT EAST | Nov 10, 2024 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 30, 2026 | HPD A | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLACE AT FLOOR OF METAL PIPE AT CLOSET AT EAST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 17D, 17th STORY, 5th APARTMENT FROM SOUTH AT WEST | Open |
| Oct 30, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 17D, 17th STORY, 5th APARTMENT FROM SOUTH AT WEST | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Sep 25, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT EAST WALL, WEST WALL AND CEILING AT PUBLIC HALL, 10th STORY | Open |
| Sep 24, 2026 | ECB | Construction: FACADE WORK 20 STORY BUILDING. OBSERVED MOTORIZED SUSPENDED SCAFFOLD USING C-HOOKS, UPON REQUEST FOR THE ANNUAL MOTOR INSPECTION REPORT THE ONE PROVIDED WAS PERFORMED AT 7/21/2025 AND WHEN REQUEST FOR MANUFACT | Open |
| Sep 24, 2026 | ECB | Construction: FACADE WORK 20 STORY BUILDING. OBSERVED C-HOOK SUSPENDED SCAFFOLDS WITHOUT BEARING BLOCKING SUPPORT AT THE FACADE'S PARAPET POINT OF CONTACTCONTRARY TO DOCUMENTS PROVIDED AND AS PER 3314.10.12. NO BEARING BLOCK | Open |
| Aug 26, 2026 | HPD A | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY COVER AT ALL ELECTRICAL OUTLETS AT PUBLIC HALL, 1st STORY, SECTION ''333'' | Open |
| Aug 26, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE CLOSER ARM LOCATED IN THE ENTRANCE DOOR TO BUILDING , 1st STORY, SECTION ''333'' | Closed |
| Aug 26, 2026 | HPD A | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY COVER AT ALL ELECTRICAL OUTLETS AT PUBLIC HALL, 4th STORY, SECTION ''333'' | Open |
| Aug 26, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 8M, 8th STORY, 3rd APARTMENT FROM NORTH AT EAST | Open |
| Aug 12, 2026 | HPD A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 12, 2026 | HPD A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 5, 2026, 3:43 PM ET. BBL 4159450001.