6 floors · 64,415 sq ft · built 1976 · class I9 · owner of record: Beach 65 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 64,415 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 181 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 181 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 425 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 15908). Agency page | Dec 31, 2028 in 791 days | Next due 2028 |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-04 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 2, 2026 | Unknown CLASS - 1 FAILURE TO INSTALL GROUNDING ELECTRODE CONDUCTOR IN ACCORDANCE WITH SECTION. OBSERVED IN THE MAIN ELECTRICAL RM NO INSTALLATION OF ELECTRODE GROUND ROD. EC 250.64, PROPERLY INSTALL GROUND ELECTRODE CONDUCTOR #39183048R | Apr 19, 2027 PENDING | $4,800 |
| Apr 2, 2026 | Unknown CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN THE OFFICE CUBICLES THE USE OF FLEX CORDS TO POWER ALSO IN THE BOILER RM ELECTRIC WIRE #39183049Z | Apr 19, 2027 PENDING | $1,600 |
| Apr 2, 2026 | Unknown CLASS - 1 FAILURE TO PROTECT CONDUCTOR(S) AGAINST OVERCURRENT PER EC. OBSERVED IN THE ELEVATOR MACHINE RM THAT THE OVERCURRENT PROTECTION IS INCORRECTLY SIZED. EC 240.4 MUST FOLLOW CODE., PROVIDE PROTECTION AGAINST OVERC #39183050X | Apr 19, 2027 PENDING | $4,800 |
| Feb 5, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BUILDINGS FOR SUMMONS 39142831H, FILE A CERTIFICATE OF CORRECTION #39176239Y | Apr 14, 2026 DEFAULT | $6,250 |
| Mar 26, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED NON FIRE RATED DOOR AT 1 FLOOR LEVEL NEAR STAFF LOUNGE AREA CORRIDOR. POTENTIAL FIRE HAZARD., REPAIR AND/REPLACE #39142831H | Jul 15, 2025 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 12, 1989 | ELEVATOR #1214D/1 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 26, 2026 | C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WOOD WEDGE AT FIRE DOOR LEADING TO COMMUNITY ROOM AT WEST WALL AT PUBLIC HALL, 6th STORY | Nov 9, 2026 |
| Oct 26, 2026 | C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WOOD WEDGE AT FIRE DOOR LEADING TO COMMUNITY ROOM AT WEST WALL AT PUBLIC HALL, 4th STORY | Nov 9, 2026 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 26, 2026 | HPD C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WOOD WEDGE AT FIRE DOOR LEADING TO COMMUNITY ROOM AT WEST WALL AT PUBLIC HALL, 6th STORY | Open |
| Oct 26, 2026 | HPD C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WOOD WEDGE AT FIRE DOOR LEADING TO COMMUNITY ROOM AT WEST WALL AT PUBLIC HALL, 4th STORY | Open |
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 3:00 AM ET. BBL 4159080007.