Staten Island · Block 8 · Lot 19 · 10301

299 St Marks Place

6 floors · 70 apartments · 56,724 sq ft · built 1951 · class D1 · owner of record: 299 St Marks Place, Llc

117open violations
$0ECB/OATH penalties owed
44HPD class C (immediately hazardous)
52dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 52 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 52 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 68 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 56,724 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 173 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 173 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 296 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 783 days
Next cycle year 2028
Energy audit and retro-commissioning (2028) Likely applies
Local Law 87 · Calendar year 2028
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 8). Agency page

Dec 31, 2028
in 783 days
Next due 2028
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-08 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (0)

None open.

DOB NOW Safety (4)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
HPD (113) · C 44 · B 54 · A 15
IssuedClassViolationCorrect by
Oct 5, 2026AApt S9 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHJan 8, 2027
Oct 5, 2026AApt S9 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHJan 8, 2027
Oct 5, 2026CApt S9 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOct 31, 2026
Oct 5, 2026AApt S9 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILINGS AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHJan 8, 2027
Oct 5, 2026CApt S9 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH IN THE ENTRANCE LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOct 19, 2026
Oct 5, 2026BApt S9 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHNov 9, 2026
Oct 1, 2026AApt S9 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHJan 4, 2027
Oct 1, 2026AApt S9 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILINGS AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHJan 4, 2027
Oct 1, 2026AApt S9 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHJan 4, 2027
Oct 1, 2026CApt S9 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOct 27, 2026
Oct 1, 2026BApt S9 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHNov 5, 2026
Oct 1, 2026CApt S9 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH IN THE ENTRANCE LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOct 15, 2026
Sep 23, 2026BApt 302 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 302, 3rd STORY, 4th APARTMENT FROM NORTH AT EASTOct 28, 2026
Sep 8, 2026AApt 310 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 310, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 12, 2026
Sep 8, 2026CApt S8 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S8, 3rd BSMT-APT FROM SOUTH AT WESTOct 4, 2026
Sep 8, 2026CApt S8 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S8, 3rd BSMT-APT FROM SOUTH AT WESTOct 4, 2026
Sep 8, 2026AApt 310 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WOOD TRIM AT EAST IN THE BATHROOM LOCATED AT APT 310 , 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 12, 2026
Sep 8, 2026AApt 310 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WINDOW FRAME AT EAST IN THE BATHROOM LOCATED AT APT 310 , 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 12, 2026
Sep 8, 2026AApt 310 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 310, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 12, 2026
Sep 1, 2026BApt 209 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 209, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTHOct 6, 2026
Sep 1, 2026BApt 209 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 209, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTHOct 6, 2026
Sep 1, 2026BApt 209 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 209, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTHOct 6, 2026
Sep 1, 2026BApt 209 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 209, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTHOct 6, 2026
Aug 28, 2026BApt 211 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 211, 2nd STORY, 2nd APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 611 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 611, 6th STORY, 2nd APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 605 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 605, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTOct 2, 2026
Aug 28, 2026BApt 509 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 509, 5th STORY, 5th APARTMENT FROM SOUTH AT WESTOct 2, 2026
Aug 28, 2026BApt 411 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 411, 4th STORY, 2nd APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 403 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 403, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 2, 2026
Aug 28, 2026BApt 101 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 101, 1st STORY, 3rd APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 304 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 304, 3rd STORY, 5th APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 303 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 303, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHOct 2, 2026
Aug 28, 2026BApt 301 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 301, 3rd STORY, 3rd APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 208 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 208, 2nd STORY, 4th APARTMENT FROM SOUTH AT WESTOct 2, 2026
Aug 28, 2026BApt 205 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 205, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 2, 2026
Aug 28, 2026BApt 204 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 204, 2nd STORY, 5th APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 201 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 201, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 111 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 111, 1st STORY, 2nd APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 108 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 108, 1st STORY, 4th APARTMENT FROM SOUTH AT WESTOct 2, 2026
Aug 28, 2026BApt 103 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 103, 1st STORY, 5th APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 310 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 310, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOct 2, 2026
Aug 28, 2026BApt 306 · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 306, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WESTOct 2, 2026
Jul 31, 2026C§ 27-2056.4(H) AND 27-2056.17 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES.Aug 4, 2026
Jul 31, 2026C§ 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS.Aug 4, 2026
Jul 22, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT NORTH YARDAug 26, 2026
Jul 22, 2026B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS ON 4TH STORY BALCONY FIRE ESCAPE AT BUILDING FRONTAug 26, 2026
Jun 22, 2026BApt 310 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 310, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18653551 ISSUED 18-FEB-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017Jul 27, 2026
Jun 16, 2026BApt S8 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW AT WEST IN THE BATHROOM LOCATED AT BSMT-APT S8Jul 21, 2026
Jun 16, 2026BApt S8 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW AT NORTH IN THE 1st ROOM FROM EAST LOCATED AT BSMT-APT S8Jul 21, 2026
Jun 16, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMASep 19, 2026
Jun 16, 2026CApt S8 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S8Jul 12, 2026
Jun 16, 2026CApt S8 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S8Jul 12, 2026
Feb 25, 2026CApt 110 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 110, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHMar 23, 2026
Feb 20, 2026B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS ON 4TH STORY BALCONY AT STACK FROM NORTH AT BUILDING FRONT AT FIRE ESCAPEMar 27, 2026
Feb 20, 2026AApt 310 · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION RISER PIPE AT WEST WALL IN THE BATHROOM LOCATED AT APT 310, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHMay 26, 2026
Feb 20, 2026CApt 310 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 310, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHMar 18, 2026
Jan 5, 2026CApt 205 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 205, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''Jan 31, 2026
Nov 5, 2025B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS INSIDE COMPACTOR CLOSET AT PUBLIC HALL, 5th STORYDec 10, 2025
Nov 5, 2025B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS INSIDE COMPACTOR CLOSET AT PUBLIC HALL, 3rd STORYDec 10, 2025
Nov 5, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT NORTH YARDDec 10, 2025

Showing 60 of 113. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Oct 5, 2026HPD A§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 5, 2026HPD A§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 5, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 5, 2026HPD A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILINGS AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 5, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH IN THE ENTRANCE LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 5, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 1, 2026HPD A§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 1, 2026HPD A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILINGS AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 1, 2026HPD A§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 1, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 1, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Oct 1, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH IN THE ENTRANCE LOCATED AT BSMT-APT S9, 2nd BSMT-APT FROM WEST AT NORTHOpen
Sep 23, 2026HPD B§ 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 302, 3rd STORY, 4th APARTMENT FROM NORTH AT EASTOpen
Sep 8, 2026HPD A§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 310, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 8, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S8, 3rd BSMT-APT FROM SOUTH AT WESTOpen
Sep 8, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT S8, 3rd BSMT-APT FROM SOUTH AT WESTOpen
Sep 8, 2026HPD A§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WOOD TRIM AT EAST IN THE BATHROOM LOCATED AT APT 310 , 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 8, 2026HPD A§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WINDOW FRAME AT EAST IN THE BATHROOM LOCATED AT APT 310 , 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 8, 2026HPD A§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 310, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 1, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 209, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTHOpen
Sep 1, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 209, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTHOpen
Sep 1, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 209, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTHOpen
Sep 1, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 209, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTHOpen
Aug 28, 2026HPD B§ 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 211, 2nd STORY, 2nd APARTMENT FROM NORTH AT EASTOpen
Aug 28, 2026HPD B§ 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 611, 6th STORY, 2nd APARTMENT FROM NORTH AT EASTOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 9, 2026, 5:47 PM ET. BBL 5000080019.

Look up another building