5 floors · 43 apartments · 48,000 sq ft · built 1924 · class C1 · owner of record: 2956 Bainbridge Associates, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 64 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-26 (Accepted). Agency page | Dec 31, 2026 in 64 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 80 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 48,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 185 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 185 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 308 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1160 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 8, 1995 | Construction Non-Hazardous FAILURE TO MAINTAIN THE REAR EXTERIOR CHIMNEY FLUE THE TIN FLUE THAT COMES OUT OF THE TOP OF THE CHIMNEY HAS COLLAPSED OUT OF PLUMB OVER THE REAR YARD BY APPROXIMATELY 10INCHES THE LENGTH OF THE TIN IS APPROX 1 #34129605L | Feb 9, 1996 WRITTEN OFF | $0 |
| Nov 14, 1995 | Construction Non-Hazardous WORK WITHOUT A PERMIT. WORK NOTED: CONSTRUCTED INTERIOR PORTITION AND 2 BATHROOM AT FRONT EAST AND WEST BASEMENT. REMEDY: FILE PLANS & OBTAIN APPROVAL AND PERMIT OR RESTOR BACK TO LEGAL PRIOR CONDITION. #34129485X | Feb 23, 1996 WRITTEN OFF | $0 |
| Jan 10, 1994 | Construction Non-Hazardous WORK WIHTOU A PERMIT WORK NOTED. CONSTRUCTED INTERIOR PARTITION AND CREATED TWO HABITABLE APARTMENT WITH LIVING ROOM BEDROOM, AND BATHROOMAT FRONT EAST AND WEST OF BSMT. REMEDY:FILE PLANS AND OBTAIN APPROVAL #34102571M | Apr 15, 1994 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2024 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2400847 | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #14419 | DOB VIOLATION - ACTIVE |
| Aug 29, 1995 | LOCAL LAW 62/91 - BOILERS #15360 | DOB VIOLATION - ACTIVE |
| May 17, 1993 | LOCAL LAW 62/91 - BOILERS #01766 | DOB VIOLATION - ACTIVE |
| Jun 6, 1990 | CONSTRUCTION #C7J1 | DOB VIOLATION - ACTIVE |
| Jun 6, 1990 | CONSTRUCTION #7J1 | DOB VIOLATION - ACTIVE |
| Oct 10, 1989 | CONSTRUCTION #07J04 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2024 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Feb 10, 1997 | Boiler LL6291 | Active |
| Aug 29, 1995 | Boiler LL6291 | Active |
| May 17, 1993 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Mar 26, 2024 | B | § 27-2005 ADM CODE PROVIDE AN UNLOCKABLE SLIDE BOLT OR HOOK ON ROOF DOOR THAT ALLOWS RE-ENTRY FROM ROOF TO PUBLIC HALLWAY AT SOUTH SECTION BULKHEAD DOOR 6TH STORY ROOF | Apr 30, 2024 |
| Mar 26, 2024 | B | § 27-2005 ADM CODE PROVIDE AN UNLOCKABLE SLIDE BOLT OR HOOK ON ROOF DOOR THAT ALLOWS RE-ENTRY FROM ROOF TO PUBLIC HALLWAY AT NORTH SECTION BULKHEAD DOOR 6TH STORY ROOF | Apr 30, 2024 |
| Mar 26, 2024 | B | § 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION FROM SUNSET TO SUNRISE AT SOUTH FIRE PASSAWAY | Apr 30, 2024 |
| Mar 26, 2024 | B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SPARK ARRESTOR AT ROOF CHIMNEY | Apr 30, 2024 |
| Oct 16, 2019 | B | Apt 5E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 5E, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH | Nov 20, 2019 |
| May 4, 2007 | B | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASHES BOTTOM THRU OUT BASEMENT SOUTH WALKIN APT GF. | Jun 27, 2007 |
| May 4, 2007 | B | § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE THRU OUT BASEMENT SOUTH WALKIN APT GF. | Jun 27, 2007 |
| May 4, 2007 | B | Apt G-F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT G-F, 1st APARTMENT FROM NORTH AT EAST | Jun 27, 2007 |
| May 4, 2007 | B | Apt G-F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST LOCATED AT APT G-F, 1st APARTMENT FROM NORTH AT EAST | Jun 27, 2007 |
| May 4, 2007 | B | Apt G-F · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR IN THE 4th ROOM FROM EAST LOCATED AT APT G-F, 1st APARTMENT FROM NORTH AT EAST | Jun 27, 2007 |
| May 4, 2007 | B | Apt 5B · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CEILING FIXTURE FRONT PRIVATE HALL 3RD STY NORTHWEST APT 5B NORTH SECTION. LOCATED AT APT 5B | Jun 27, 2007 |
| May 4, 2007 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING EAST ROOM 5TH STY NORTHWEST APT 5B NORTH SECTION. LOCATED AT APT 5B | Jun 27, 2007 |
| May 4, 2007 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING BATHROOM 5TH STY NORTHWEST APT 5B NORTH SECTION. LOCATED AT APT 5B | Jun 27, 2007 |
| May 4, 2007 | B | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW GLASS BOTTOM CENTER ROOM BASEMENT SOUTH WALK IN APT GF. | Jun 27, 2007 |