17 floors · 226 apartments · 223,067 sq ft · built 1969 · class D1 · owner of record: Nyc Housing Authority
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 223,067 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 7057). Agency page | Dec 31, 2027 in 423 days | Next due 2027 |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page | Feb 21, 2028 in 475 days | No Cycle 10 report on record yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1154 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 25, 2026 | Boilers CLASS - 3 @THE HOT WATER MECHANICAL ROOM>THE HEAT EXCHANGER GASKET IS LEAKING WATER+CHECK VALVE IS LEAKING STEAMÝMAKING NOISE¨+REAR OF VARI VAC SYSTEM THERE IS A PIPE LEAKING WATER+BOTH WATER PRESSURE PUMP MOTORS NEED LU #39193829Z | Jul 9, 2026 POP/IN-VIO | $0 |
| Apr 8, 2026 | Unknown CLASS - 2 DURING MY INSPECTION AND UPON REVIEWING DOB NOW AND BIS SYSTEM REVEALS SSM / SSC ON MULTIPLE PERMITS NOT IN COMPLIANCE TO CODE BC 3310.5.4 NO WORK ALLOWED UNDER APPLICATION 321187327-01-AL EXCEPT TO UPDATE P #39552805X | Jan 8, 2027 PENDING | $2,500 |
| Dec 30, 2025 | Unknown CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY BUILDING, I OBSERVED 2 WORKERS OPERATING AERIAL LIFT, UPON REQUEST FOR 40HRE SITE SAFETY CARD NONE WAS PRESENTED OR AT JOBSITE. FAILURE TO HAVE EACH WORKER SUCCESSFULL #39548605J | Dec 7, 2026 PENDING | $5,000 |
| Dec 30, 2025 | Unknown CLASS - 2 AT THE TIME OF MY INSPECTION OF A 17 STORY BUILDING, I OBSERVED DE WATERING TANK ON SITE, UPON REQUEST FOR DEP PERMIT THE ONE THAT WAS PRESENTED WAS EXPIRED 12-06-2024, FAILURE PROVIDE AND MAINTAIN DEP PERMIT #39548607N | Dec 7, 2026 PENDING | $2,500 |
| Dec 30, 2025 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY BUILDING, I OBSERVED 2 WORKERS OPERATING AERIAL LIFT, UPON REQUEST FOR CERTIFICATION TO OPERATE NONE WAS PRESENTED OR AT JOBSITE. FAILURE TO COMPLY WITH MANUFACTURE SP #39548606L | Dec 7, 2026 PENDING | $2,500 |
| Jul 10, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES.AS NOTEDAT THE TIME OF INSPECTION I OBSERVED ON EXPOSURE#2 NORTH ELEVATION:DAMAGED MISSING MORTAR JOINTS IN BRICK WORK.ALSO LOOSE BRICKS EXPOSURE#3 #35718333Z | Aug 27, 2025 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jul 10, 2025 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO LARGE OPEN CRACKS ON BULKHEAD/WATER TANK BRICK ENCLOSURE. APPEAR TO BE IMMINENTAL HAZARDOUS. OBSERVED ON EXPOSU #3 EAST ELEVATION ON BULKHEAD/WATER TANKS ENCLOSURE:BULGING,CRACKS PEELING BRICKWORK. REMEDY:IMMED RETAIN NYS LP TO SUPERVISE STABILIZATI & REPAIR UNINSTALL PEE #LL1301RF | DOB VIOLATION - ACTIVE |
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #00229 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2023 | Facades FISPNRF CYCLE 9B NO REPORT FILED | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 22, 2012 | B | Apt 7K · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION DRAIN LINE AT SINK IN THE KITCHEN LOCATED AT APT 7K, 6th STORY, APARTMENT AT WEST | Jul 27, 2012 |
| Jun 22, 2012 | B | Apt 7K · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 7K, 7th STORY, APARTMENT AT WEST | Jul 27, 2012 |
| Jun 22, 2012 | B | Apt 7K · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 7K, 7th STORY, APARTMENT AT WEST | Jul 27, 2012 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Closed |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Closed |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 5:35 AM ET. BBL 3070570012.