Manhattan · Block 2105 · Lot 1 · 10039

2930 8 Avenue

3 floors · 41,446 sq ft · built 1954 · class N2 · owner of record: Nyc Department Of Homeless Services

52open violations
$2,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
62dto Annual boiler inspection (2 boilers)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-07-01 (Accepted). Agency page

Dec 31, 2026
in 62 days
2 of 2 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 41,446 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 183 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 183 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 793 days
Next cycle year 2028

Open violations

ECB / OATH (46) · $2,500 owed
IssuedViolationHearingBalance
Sep 30, 2026Boilers CLASS - 2
FOUND FITZGIBBONS OIL FIRED BOILER MODEL#99042 WITH DEFECTIVE SAFETY RELIEF VALE(LEAKING). SECONDARY BOILER ROOM DOOR NOT SELF CLOSING. POOR LIGHTING IN BOILER ROOM.
#39206155L
Oct 28, 2026
PENDING
$1,250
Sep 30, 2026Boilers CLASS - 2
FOUND FITZGIBBON OIL FIRED BOILER MODEL#99042 WITH CORRODED AND LEAKING BOILER BASE, SAFETY RELIEF VALVES DEFECTIVE , LEAKING AND LABELS NOT LEGIBLE, EXPOSED WIRES AT CONTROLS, OIL PUMP SET NOT TO RUN CONSTANT.
#39206150M
Oct 28, 2026
PENDING
$1,250
Nov 19, 2024Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED CEILING CHIPPED AND FALLING OFF CEILING. THIS IS A OVERHEAD HAZARD. LOCATED IN AUDITORIUM/ LUNCHROOM., REPAIR AND/REPLACE
#39130734H
Nov 21, 2024
POP/IN-VIO
$0
Jun 3, 2024Unknown CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS AS STATED IN ECB# 39077703P ISSUED ON 01/11/2023 AND FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01 FOR FAILURE TO GROUND ELEC
#39115811R
Jul 27, 2024
POP/IN-VIO
$0
Jun 3, 2024Unknown CLASS - 1
I OBSERVED IN THE MAIN ELECTRICAL ROOM THE SERVICE DISCONNECT SWITCH IMPROPER FUSING. THE SWITCH HAS (2) 300 AMP FUSES AND (1) 400 AMP FUSE. ALL FUSES IN A DISCONNECT SHALL BE COORDINATED., PROVIDE PROTECTION A
#39115807Y
Jul 27, 2024
POP/IN-VIO
$0
Jun 3, 2024Construction CLASS - 1
FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS AS STATED IN ECB# 39077701L ISSUED ON 01/11/2023 FOR IMPROPER FUSING OF ELECTRICAL CONDUCTORS AND FILE A CERTIFICATE OF CORRECTION AS PURSUANT TO 28-201.1 AND 1RCNY
#39115806M
Aug 2, 2024
POP/IN-VIO
$0
Mar 7, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS AS STATED IN ECB # 39077703P ISSUED ON 01/11/2023 AND FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE TO SAFEGUARD PER
#39108326H
May 30, 2024
POP/IN-VIO
$0
Mar 7, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS AS STATED IN ECB # 39077698J ISSUED ON 01/11/2023 AND FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE TO SAFEGUARD PER
#39108246H
May 30, 2024
POP/IN-VIO
$0
Mar 7, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS AS STATED IN ECB # 39077701L ISSUED ON 01/11/2023 AND FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE TO SAFEGUARD PER
#39108245X
May 30, 2024
POP/IN-VIO
$0
Dec 20, 2023Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39077701L ISSUED ON 08/03/23 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY
#39101876K
Jan 2, 2024
POP/IN-VIO
$0
Dec 20, 2023Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39077698J ISSUED ON 01/11/23 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY
#39101888H
Jan 2, 2024
POP/IN-VIO
$0
Dec 20, 2023Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39077703P ISSUED ON 01/13/23 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY
#39101874R
Jan 2, 2024
POP/IN-VIO
$0
Oct 25, 2023Unknown CLASS - 1
I OBSERVED IN THE MAIN ELECTRICAL ROOM THE INSTALLATION OF THE GROUND BAR FOR THE SERVICE DISCONNECTS WITH NO MAIN CONDUCTOR FROM THE WATER MAIN. A SUPPLEMENTAL GROUND ROD IS PROVIDING THE PRIMARY GROUND., PROV
#39098023Y
Nov 15, 2023
POP/IN-VIO
$0
Oct 25, 2023Unknown CLASS - 1
I OBSERVED IN THE MAIN ELECTRICAL ROOM THE INSTALLATION OF (2) 300 AMP FUSES AND (1) 400 AMP FUSE. THIS IS NOT PERMITTED ALL FUSING OF CONDUCTORS SHALL BE THE SAME RATING. PHOTOS TAKEN., PROVIDE PROTECTION AGAI
#39098022M
Nov 15, 2023
POP/IN-VIO
$0
Jan 13, 2023Unknown CLASS - 1
I OBSERVED IN THE ELECTRICAL SERVICE ROOM THE INSTALLATION OF A GROUND BAR FOR THE SERVICE DISCONNECTS WITH NO MAIN GROUND ELECTRODE CONDUCTOR FROM THE WATER MAIN. A SUPPLEMENTAL GROUND ROD IS SUPPLYING THE PRI
#39077703P
Jan 25, 2023
POP/IN-VIO
$0
Jan 11, 2023Construction CLASS - 2
OBSERVED: FIRE PROOF SELF-CLOSING DOOR AT SECOND FL, SMOKE DOOR NEAR RM 213 & FIRST FL, EXIT DOORS # 3,4,2, LIBRARY (OBSTRUCTION EXIT WAY) & CAFETERIA (3 DOORS) ALSO, CAFETERIA/ EXIT DOOR ARE MISSING PUSH BARS.
#39077513Y
Jan 25, 2023
POP/IN-VIO
$0
Jan 11, 2023Unknown CLASS - 1
I OBSERVED IN THE MAIN ELECTRICAL ROOM THE INSTALLATION OF (2) 300 AMP FUSES AND (1) 400 AMP FUSES. THIS NOT PERMITTED ALL FUSING OF CONDUCTORS ARE TO BE OF THE SAME RATING. PHOTOS TAKEN., PROVIDE PROTECTION AG
#39077701L
Jan 25, 2023
POP/IN-VIO
$0
Jan 11, 2023Unknown CLASS - 2
I OBSERVED IN THE MAIN DISCONNECT SWITCHES THE ELECTRICAL ROOM THE IMPROPER TERMINATION OF THE CONDUCTORS .FOR THE TERMINATION OF TWO CONDUCTORS UNDER A SINGLE LUG IT SHALL BE OF THE TYPE DESIGNED FOR SUCH INST
#39077700J
Jan 25, 2023
POP/IN-VIO
$0
Jan 11, 2023Unknown CLASS - 1
I OBSERVED ON ROOFTOP A THE USE OF FLEXIBLE RUBBER CORD THROUGH THE CONCRETE WALL AND IMPROPERLY SPLICED WITH EXPOSED AND ENERGIZED WIRING SUPPLYING POWER TO THE DOWN LIGHT. AS EC 400.8 FLEXIBLE CORDS ARE NOT P
#39077698J
Jan 25, 2023
POP/IN-VIO
$0
Jan 11, 2023Unknown CLASS - 2
I OBSERVED ON THE ROOFTOP "A" SIDE 8(#S 5-6-8-9-10-11-13-14) DEFECTIVE/INOPERABLE EXHAUST FANS. PHOTOS TAKEN, COMPLY WITH EC; REPAIR/OR REPLACE DEFECTIVE EQUIPMENT.
#39077699L
Jan 25, 2023
POP/IN-VIO
$0
May 13, 2022Boilers CLASS - 2
REPAIR CLAMP USED TO STOP LEAK-CORROSION ON VALVE BOILER NO. 2-PIPING UNCAPPED AT MIXING VALVE AND PIPING CAPPED W/WASTE FITTING-ELECTRICAL CONNECTION BOX FOR FIRE SWITCH W/O A COVER-NO SHUT-OFF VALVE FUEL OIL
#39062066J
Jun 8, 2022
POP/IN-VIO
$0
Dec 7, 2021Construction CLASS - 1
I OBSERVED IN THE MAIN ELECTRICAL ROOM, AN EXCESSIVE AMOUNT OF WATER LEAKING FROM ABOVE ONTO THE MAIN ELECTRICAL EQUIPMENT. EQUIPMENT IS CURRENTLY BEING DETERIORATED, AND THE WATER POOLING CAN LEAD TO A SHOCK H
#39052532Z
Dec 13, 2021
POP/IN-VIO
$0
Sep 22, 2021Boilers CLASS - 2
FOUND FITZGIBBON BOILER ACTIVE WITH DEFECTS. COMBUSTION AIR FAN SAIL SWITCH DEFECTIVE. CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION.
#39047921X
Oct 15, 2021
POP/IN-VIO
$0
Aug 27, 2021Construction CLASS - 1
AN UNLAWFUL ACT.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.FAILURE TO CORRECT AND CERTIFY SUMMONS#35253004K ISSUED ON 4/12/2017,FORFAILURE TO GROUND THE ELECTRICAL SERVICE IN THE BASEMENT.ALSO SUMMONS#
#35583956J
Nov 18, 2021
POP/IN-VIO
$0
Sep 23, 2019Construction CLASS - 2
NOTED: EXIT DOORS AT 3RD AND 2ND FLOOR STAIRWAY A, AND 1ST FLOOR STAIRWAY B, DO NOT SELF CLOSE, DOORS ARE RUBBING ON THE FLOOR. , REPAIR/REPLACE DOOR
#39009882P
Oct 4, 2019
POP/IN-VIO
$0
Sep 23, 2019Unknown CLASS - 2
I OBSERVED IN THE ELECTRICAL EQUIPMENT ROOM THE INSTALLATION OF TWO SERVICE SWITCHES WITH CONDUITS AND WIRING TO SUPPLY POWER TO THE KITCHEN AND A SECOND UNSPECIFIED LOCATION. THE CONNECTIONS TO PROVIDE POWER A
#39009890P
Oct 4, 2019
POP/IN-VIO
$0
Sep 23, 2019Unknown CLASS - 1
I OBSERVED IN THE ELECTRICAL ROOM, SERVICE SWITCHES WITH IMPROPER FUSING , , PROVIDE PROTECTION AGAINST OVERCURRENT; INSTALL FUSES UNIFORMLY.
#39009891R
Oct 4, 2019
POP/IN-VIO
$0
Sep 23, 2019Construction CLASS - 2
NOTED: OPERATING A PLACE OF ASSEMBLY AT 1ST FLOOR CAFETERIA/GYM, WITHOUT A VALID CERTIFICATE TO OPERATE, TABLES AND CHAIRS ARRANGED FOR SEATING 93 PERSONS., OBTAIN PLACE OF ASSEMBLY CERTIFICATE OF OPERATION
#39009883R
Oct 4, 2019
POP/IN-VIO
$0
Sep 23, 2019Unknown CLASS - 1
I OBSERVED IN THE ELECTRICAL SERVICE ROOM THE INSTALLATION OF A GROUND BAR FOR THE SERVICE DISCONNECTS WITH NO MAIN GROUNDING ELECTRODE CONDUCTOR FROM THE WATER MAIN. A SUPPLEMENTAL GROUND ROD CONDUCTOR IS SUPP
#39009889H
Oct 4, 2019
POP/IN-VIO
$0
May 8, 2019Boilers CLASS - 2
PIPING ON FEED WATER LEAK-SMOKE ALARM DEFECTIVE-BACKFLOW DRAIN NOT CONNECTED-SURFACE BLOW DOWN DRAIN NOT PIPED-BODY DRAINS NOT INSTALLED ON SAFETY VALVES-FLAME GLASS MISSING-LOW WATER CUTOFF VALVE DEFECTIVE; CO
#39002754Z
May 9, 2019
POP/IN-VIO
$0
Apr 17, 2019Construction CLASS - 2
WORK WITHOUT A PERMIT. OBSERVED IN CELLAR PLUMBING WORK DONE TO REMOVE TWO TEMPORARY AVL PIPES LINE FROM TWO BOILERS WITHOUT A PERMIT. REM: OBTAIN ALL REQUIRED PERMITS.
#35415222H
Apr 22, 2019
POP/IN-VIO
$0
Aug 21, 2018Boilers CLASS - 2
B254,42,50A-50F 50A-NEED SUMP PUMP TO BE REPAIRED OR REPLACED; 50B- SMOKE ALARM NOT WORKING; 50C-FRESH AIR FAN NOT WORKING AND MISSING SAIL SWITCH; 50D- NO OPEN BALL VALVES; 50E-MISSING ADDER AND PLATFORM
#32097010X
Oct 25, 2018
POP/IN-VIO
$0
Apr 2, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPIANT MANNER. OBSERVED ON 4218 AT ABOVE ADDRESS ACTIVE LEAK ON WATER PIPING IN WATER/SPRINKLER ROOM. RMDY: REPAIR AND/OR REPLACE. PHOTOS TAKEN.............................
#35326458J
Jun 21, 2018
POP/IN-VIO
$0
Feb 2, 2018Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. IN AUGUST 21, 2017, 28, 17, APRIL 12, 2017. FOUR ELECTRICAL VIOLATIONS WAS ISSUED TO THE RESPONDENT. THE RESPONDENT FAILED TO COMPLY WITH (NYC
#35312723Y
Apr 5, 2018
POP/IN-VIO
$0
Aug 28, 2017Plumbing CLASS - 2
FAIL TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.RC:INSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER P.C. 102.3;27-902. OBSERVED ON 8/28/17 AT ABOVE ADDRESS JIM CAPS INSTALLED IN BASEMENT OUTSIDE
#35290537X
Dec 14, 2017
POP/IN-VIO
$0
Aug 28, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNE:NO FIRE STOPPING PER BC 712.3:27-345. NOTED: AT CELLAR IN GAS METER ROOM,OPENINGS AROUND PLUMBING ELIMINATING FIRE STOPPING.REMEDY:PROVIDE/MAINTAIN FIRE STOP
#35290354N
Dec 14, 2017
POP/IN-VIO
$0
Aug 28, 2017Unknown CLASS - 2
FAIL TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS/ ENCLOSURES/CABLE ARMOR.OBSERVED SEALTITE IN KITCHEN DISCONNECTED FROM FIXED APPLIANCE WAITH WIRING EXPOSED.REMEDY:COMPLY WITH CODE/PROVIDE
#35290390K
Dec 14, 2017
POP/IN-VIO
$0
Aug 28, 2017Construction CLASS - 2
OPERATION OF A PLACE OF ASSEMBLY WITHOUT A CURRENT CERTIFICATE OF OPERATION.NOTED: NO CURRENT CERTIFICATE OF OPERATION FOR 1ST STORY CAFETERIA WITH MAXIMUM OCCUPANCY SIGN FOR 365 PERSON.REMEDY:OBTAIN A PLACE
#35290353L
Dec 14, 2017
POP/IN-VIO
$0
Aug 28, 2017Unknown CLASS - 1
110.4 CONDUCTORS NOT PROPERLY INSTALLED /TERMINATED . OBSERVED PRIOR CONDITION NOT RECTIFIED AS PER PREVIOUS ECB #35253006Y. TWO CONDUCTORS TERMINATED UNDER A SINGLE LUG TERMINAL NOT DESIGNED FOR INSTALLATION
#35290388L
Dec 14, 2017
POP/IN-VIO
$0
Aug 21, 2017Construction CLASS - 1
UNLAWFUL ACTS.FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.IN APRIL 12,2017, JUNE 26,2017.THREE ELECTRICAL VIOS WAS ISSUE TO THE RESPONDENT.THE RESPONDENT FAILED TO COMPLY W/(NYC) ELECTRICAL CODE #250.4,110
#35284858X
Dec 21, 2017
POP/IN-VIO
$0
Jun 26, 2017Construction CLASS - 1
AN UNLAWFUL ACT. FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER. FAILED TO CORRECT & CERTIFY ECB#35253004K RECEIVED ON 3-12-17 FOR BROKEN OR MISSING THE MAIN HOUSE AROUNDING WIRE WHICH WAS CONNECTED TO THE
#35228248M
Aug 10, 2017
POP/IN-VIO
$0
Apr 12, 2017Plumbing CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. RE: INSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC 102.3;27-302. OBSERVED ON 4/12/17 @ ABOVE ADDRESS JIM CAPS & ALSO IN ELECTRIC METER ROOM.
#35252954J
May 11, 2017
POP/IN-VIO
$0
Apr 12, 2017Unknown CLASS - 1
FAILURE TO GROUND ELECTRICAL SYSTEM. AT THE TIME OF INSP. I OBSERVED THE MAIN BLDG GROUND WAS CUT OFF FROM THE BLDG WATER MAIN PIPE. THIS ISAN IMMEDIATE HAZARD TO PERSON & PROPERTY AS IT DOESN'T ALLOW INCIDENTA
#35253004K
May 11, 2017
POP/IN-VIO
$0
Apr 12, 2017Unknown CLASS - 1
EC110.14A. CONDITIONS NOT PROPERLY INSTALLED/TERMINATED. I OBSERVED @ TIME OF INSP. THE OUTDOOR A.C. SERVICE SWITCHES WITH 2 CONDUCTORS SERVICE UNDER A SINGLE TERMINAL LUG, BSMT SERVICE SWITCHES WITH 2 CONDUCTO
#35253006Y
May 11, 2017
POP/IN-VIO
$0
Aug 8, 2016Construction CLASS - 2
OPERATION OF A PLACE OF ASSEMBLY W/O A CURRENT CERTIFICATE OF OPERAT TION(PACO) NOTED: NO CURRENT CERTIFICATE OF OPERATION FOR 1ST FLOOR CAFETERIA WITH MAXIMUM OCCUPANCY SIGN POSTED FOR 365 PERSONS.PREVIOUS
#35200759J
Nov 17, 2016
POP/IN-VIO
$0
Feb 19, 2016Construction CLASS - 2
OPERATION OF PLACE OF ASSEMBLY W/O A CURRENT CERTIFICATE OF OPERATION.NOTED: OPERATING 1ST FLR CAFETERIA W/MAXIMUM OCCUPANCY 365 PERSONS W/OCURRET CERTIFICATE OF OPERAITONS.RMDY: OBTAIN A PLACE OF ASSEMBLY CERT
#35171437R
Mar 31, 2016
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (6)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 30, 2026ECBBoilers: FOUND FITZGIBBONS OIL FIRED BOILER MODEL#99042 WITH DEFECTIVE SAFETY RELIEF VALE(LEAKING). SECONDARY BOILER ROOM DOOR NOT SELF CLOSING. POOR LIGHTING IN BOILER ROOM.Open
Sep 30, 2026ECBBoilers: FOUND FITZGIBBON OIL FIRED BOILER MODEL#99042 WITH CORRODED AND LEAKING BOILER BASE, SAFETY RELIEF VALVES DEFECTIVE , LEAKING AND LABELS NOT LEGIBLE, EXPOSED WIRES AT CONTROLS, OIL PUMP SET NOT TO RUN CONSTANT.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 4:36 PM ET. BBL 1021050001.

Look up another building