24 floors · 170,230 sq ft · built 1923 · class O4 · owner of record: 292 Madison Investor Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-03-06 (Accepted). Agency page | Dec 31, 2026 in 58 days | 2 of 2 without an accepted 2026 report yet |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $31,250 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 110 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 170,230 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1154 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1275). Agency page | Dec 31, 2035 in 3345 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 13, 2026 | Construction CLASS - 2 24 STORY ALT2 FACADE WORK ACTIVE SITE, OBSERVED WORK CONTRARY TO SUPPORTED SCAFFOLD STAIR TOWER ON 19 FL EXP#4. NO DETAILS FOR MANUAL HOIST PULLEY, NO DETAILS FOR STAIR ACCESS TO SCAFFOLD ON PLANS, TIEBACKS NOT #39560508J | Dec 17, 2026 PENDING | $1,250 |
| Oct 13, 2026 | Construction CLASS - 2 24 STORY ALT2 FACADE WORK ACTIVE SITE, OBSERVED WORK CONTRARY TO SSP/CODE INADEQUATE ROOF PROTECTION OF ADJOINING PROPERTIES AT EXP#2,3. ROOF PROTECTION NOT FULLY EXTENDED 20 FT OVER PARAPET WALL/MISSING PROTEC #39560507H | Dec 17, 2026 PENDING | $1,250 |
| Oct 13, 2026 | Construction CLASS - 2 24 STORY ALT2 FACADE WORK ACTIVE SITE. UPON REQUEST TO CONTRACTOR ONSITE FOR REQUIRED DOCUMENTS. I ASKED FOR 6 MONTH SHED INSPECTION INSTALLATION LETTER, SUPPORTED SCAFFOLD INSTALLATION LETTER. NONE PROVIDED/RE #39560509L | Dec 17, 2026 PENDING | $1,250 |
| Oct 13, 2026 | Construction CLASS - 2 24 STORY ALT2 FACADE WORK ACTIVE SITE.OBSERVED WORKER'S ON SUSPENDED SCAFFOLDS AT EXP#1,4. UPON REQUEST TO QPSS/ RIGGER FOREMAN ONSITE, FOR VALID 32 HR SUSPENDED SCAFFOLD SUPERVISOR TRAINING CARD OR 8 HR REFRES #39560504M | Dec 17, 2026 PENDING | $1,250 |
| Oct 13, 2026 | Construction CLASS - 2 24 STORY ALT2 FACADE WORK ACTIVE SITE. OBSERVED WOODEN STRUCTURE ON TOP OF SIDEWALK SHED AT EXP#4, AS PER CONTRACTOR USED FOR PROTECTION OF COPING/CORNICE. ALSO ON 19TH FL OBSERVED BLACK NETTING ATTACHED TO FAC #39560506X | Dec 17, 2026 PENDING | $1,250 |
| Oct 13, 2026 | Unknown CLASS - 2 24 STORY ALT2 FACADE WORK ACTIVE SITE IN A COMMERCIAL BUILDING. UPON REQUEST TO SUPER OF BUILDING/CONTRACTOR FOR OPP PLANS ONSITE, NONE PROVIDED/READILY AVAILABLE FOR INSPECTION 3303.10. OBSERVED ON 25 FL OFFIC #39560511K | Dec 17, 2026 PENDING | $2,500 |
| Oct 13, 2026 | Construction CLASS - 2 24 STORY ALT2 FACADE WORK ACTIVE SITE PERMIT#M01303988. WORK ON SUSPENDED SCAFFOLD, UPON REQUEST TO QPSS/RIGGER FOREMAN FOR REQUIRED DOCUMENTS AS PER CODE. NO 3RD PERSON LETTER F/ENGINEER ON SCAFFOLD EXP#1. NO #39560505Y | Dec 17, 2026 PENDING | $1,250 |
| Oct 13, 2026 | Construction CLASS - 2 24 STORY ALT2 FACADE WORK ACTIVE SITE, OBSERVED WORK CONTRARY TO SIDEWALK SHED PLANS/CODE. PERMIT#M01003530, SHED NOT FULLY EXTENDED OVER ADJOINING PROPERTY MAIN ENTRANCE AT EXP#2 AS PER 3307.6.3/3309.13. SHED #39560510Z | Dec 17, 2026 PENDING | $1,250 |
| Jul 15, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33. AT THE TIME OF INSPECTION, ACTIVE CONSTRUCTION WORK WAS OBSERVED ATTHE 27-STORY BUILDING. WORKERS WERE PERFORMING FACADE WORK. NO STRUCTU #39556626Z | Oct 8, 2026 IN VIOLATION | $1,250 |
| May 22, 2014 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONT.DOCS &/OR APPROVED AMENDMENTS.NOTED AT TIME OF INSPEC.FOR FACADE WORK PLAN SHOWS CURTAIN WALL DESIGN WHERE AS NOW PRE-EXISTING MASONRY ORCHES & EXISTING FACADE STONE BEING #35092198N | Jul 10, 2014 IN VIOLATION | $117 |
| Issued | Violation | Status |
|---|---|---|
| Jun 18, 1997 | CONSTRUCTION #05C03 | VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE |
| Jun 18, 1997 | CONSTRUCTION #05C3 | VIOLATION UNSERVED ECB-ACTIVE |
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 13, 2026 | ECB | Construction: 24 STORY ALT2 FACADE WORK ACTIVE SITE, OBSERVED WORK CONTRARY TO SUPPORTED SCAFFOLD STAIR TOWER ON 19 FL EXP#4. NO DETAILS FOR MANUAL HOIST PULLEY, NO DETAILS FOR STAIR ACCESS TO SCAFFOLD ON PLANS, TIEBACKS NOT | Open |
| Oct 13, 2026 | ECB | Construction: 24 STORY ALT2 FACADE WORK ACTIVE SITE, OBSERVED WORK CONTRARY TO SSP/CODE INADEQUATE ROOF PROTECTION OF ADJOINING PROPERTIES AT EXP#2,3. ROOF PROTECTION NOT FULLY EXTENDED 20 FT OVER PARAPET WALL/MISSING PROTEC | Open |
| Oct 13, 2026 | ECB | Construction: 24 STORY ALT2 FACADE WORK ACTIVE SITE. UPON REQUEST TO CONTRACTOR ONSITE FOR REQUIRED DOCUMENTS. I ASKED FOR 6 MONTH SHED INSPECTION INSTALLATION LETTER, SUPPORTED SCAFFOLD INSTALLATION LETTER. NONE PROVIDED/RE | Open |
| Oct 13, 2026 | ECB | Construction: 24 STORY ALT2 FACADE WORK ACTIVE SITE.OBSERVED WORKER'S ON SUSPENDED SCAFFOLDS AT EXP#1,4. UPON REQUEST TO QPSS/ RIGGER FOREMAN ONSITE, FOR VALID 32 HR SUSPENDED SCAFFOLD SUPERVISOR TRAINING CARD OR 8 HR REFRES | Open |
| Oct 13, 2026 | ECB | Construction: 24 STORY ALT2 FACADE WORK ACTIVE SITE. OBSERVED WOODEN STRUCTURE ON TOP OF SIDEWALK SHED AT EXP#4, AS PER CONTRACTOR USED FOR PROTECTION OF COPING/CORNICE. ALSO ON 19TH FL OBSERVED BLACK NETTING ATTACHED TO FAC | Open |
| Oct 13, 2026 | ECB | Unknown: 24 STORY ALT2 FACADE WORK ACTIVE SITE IN A COMMERCIAL BUILDING. UPON REQUEST TO SUPER OF BUILDING/CONTRACTOR FOR OPP PLANS ONSITE, NONE PROVIDED/READILY AVAILABLE FOR INSPECTION 3303.10. OBSERVED ON 25 FL OFFIC | Open |
| Oct 13, 2026 | ECB | Construction: 24 STORY ALT2 FACADE WORK ACTIVE SITE PERMIT#M01303988. WORK ON SUSPENDED SCAFFOLD, UPON REQUEST TO QPSS/RIGGER FOREMAN FOR REQUIRED DOCUMENTS AS PER CODE. NO 3RD PERSON LETTER F/ENGINEER ON SCAFFOLD EXP#1. NO | Open |
| Oct 13, 2026 | ECB | Construction: 24 STORY ALT2 FACADE WORK ACTIVE SITE, OBSERVED WORK CONTRARY TO SIDEWALK SHED PLANS/CODE. PERMIT#M01003530, SHED NOT FULLY EXTENDED OVER ADJOINING PROPERTY MAIN ENTRANCE AT EXP#2 AS PER 3307.6.3/3309.13. SHED | Open |
| Sep 9, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 15, 2026 | ECB | Construction: FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33. AT THE TIME OF INSPECTION, ACTIVE CONSTRUCTION WORK WAS OBSERVED ATTHE 27-STORY BUILDING. WORKERS WERE PERFORMING FACADE WORK. NO STRUCTU | Closed |
| Jul 15, 2026 | ECB | Unknown: MISCELLANEOUS VIOLATIONS. AT THE TIME OF INSPECTION OF A 27 STORY BUILDING I OBSERVED UNSAFE SUSPENDED SCAFFOLD OPERATIONS. WORKERS OPERATING SUSPENDED SCAFFOLDS AT EXP 1 AND 2 SEEN WORKER AT DIFFERENT LEVELS S | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 7:08 PM ET. BBL 1012750059.