Brooklyn · Block 8661 · Lot 85 · 11235

2915 Ocean Parkway

2 floors · 16,100 sq ft · built 1928 · class M1 · owner of record: Jewish Center Of Brighton Beach

19open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1162dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-14 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (2)
IssuedViolationHearingBalance
Apr 10, 2026Elevators CLASS - 1
CEASE USE ITEMS, MISSING DLM 3.10.12 APP K PROVIDE, DOOR RESTICTOR INOPERATIVE ASME 17.1 2.14.5.7.1, CAR NOT LEVEL 3 INCHES OFF LEVEL, 67-X-10 CAR PHONE INOPERATIVE..
#39184039J
Jun 17, 2026
ADMIT/IN-VIO
$0
Nov 3, 2017Boilers CLASS - 2
36.FOUND ROCKMILLS BOILER MODEL-MP60-2400000 BTU'S UNREGISTERED & OPERATING.REGISTER BOILER & CORRECT ANY VIOLATING CONDITIONS & SUBMIT A CERTIFICATE OF CORRECTION.
#32092254J
Feb 21, 2018
IN VIOLATION
$0
DOB (5)
IssuedViolationStatus
Oct 15, 2021ELEVATOR

#9028/706761
DOB VIOLATION - ACTIVE
Feb 7, 2000LOCAL LAW 62/91 - BOILERS

#24893
DOB VIOLATION - ACTIVE
Mar 16, 1999LOCAL LAW 62/91 - BOILERS

#24576
DOB VIOLATION - ACTIVE
Sep 16, 1997LOCAL LAW 62/91 - BOILERS

#249784
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#33363
DOB VIOLATION - ACTIVE
DOB NOW Safety (12)
IssuedViolationStatus
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Sep 6, 2019Elevators ACC1
Active
Sep 15, 2017Elevators EVCAT1
Active
Nov 14, 2016Elevators ACC1
Active
May 30, 2014Elevators ACC1
Active
Feb 19, 2002Elevators LL1081
Active
Mar 8, 2001Elevators LL1081
Active
Mar 10, 2000Elevators LL1081
Active
Mar 16, 1999Boiler LL6291
Active
Sep 16, 1997Boiler LL6291
Active
Aug 29, 1995Boiler LL6291
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 6:39 AM ET. BBL 3086610085.