4 floors · 4 apartments · 3,480 sq ft · built 2012 · class C3 · owner of record: Cruger Partners Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 425 days | Next cycle year 2027 |
None open.
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 11) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 22, 2026 | B | § 27-2050 ADM CODE PROVIDE 3 EXTRA SPRINKLER HEADS AND SUITABLE WRENCH FOR EMERGENCY PURPOSES AT O.S.Y. VALVE OF SPRINKLER IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT AT CELLAR | Oct 27, 2026 |
| Sep 22, 2026 | B | § 27-2050 ADM CODE SEAL IN OPEN POSITION THE O.S.Y. VALVE OF THE SPRINKLER SYSTEM IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT O.S.Y VALVE NOT SEALED IN OPEN POSITION AT CELLAR | Oct 27, 2026 |
| Sep 22, 2026 | C | § 27-2005, 2050 HMC: PROVIDE AN ADEQUATE SUPPLY OF WATER FOR THE WET SPRINKLER AND/OR STANDPIPE SYSTEM AT CELLAR | Sep 28, 2026 |
| Sep 22, 2026 | C | § 27-2005 HMC: IMMEDIATELY PROVIDE A FIRE GUARD AS DIRECTED BY THE NYC DEPT. OF HOUSING PRESERVATION & DEVELOPMENT (HPD) AND/OR THE NYC DEPT. OF BUILDINGS (DOB) TO PROTECT AGAINST FIRE HAZARDS OBSERVED BY HPD AND/OR DOB. FIRE HAZARDS OBSERVED BY HPD HAVE RESULTED IN THE FOLLOWING ADDITIONAL HPD VIOL | Sep 18, 2026 |
| Sep 21, 2026 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Dec 25, 2026 |
| Sep 21, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT ROOF DOOR AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 4th STORY | Oct 5, 2026 |
| Sep 21, 2026 | B | § 27-2005 ADM CODE PROVIDE UNLOCKABLE SLIDE BOLT AT NORTH ROOF DOOR THAT ALLOWES RENTRY FROM ROOF TO PUBLIC HALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 4th STORY | Oct 26, 2026 |
| Sep 21, 2026 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME READILY ACCESSIBLE FOR SIGNATURE, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT FRAME MISSING AT PUBLIC HALL, 1st STORY | Dec 25, 2026 |
| Sep 21, 2026 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Dec 25, 2026 |
| Sep 21, 2026 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGNAGE MISSING AT PUBLIC HALL, 1st STORY | Sep 27, 2026 |
| Sep 21, 2026 | A | §27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS | Dec 25, 2026 |
| Sep 21, 2026 | A | §27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX SIGNAGE MISSING AT PUBLIC HALL, 1st STORY | Dec 25, 2026 |
| Sep 21, 2026 | B | Apt 4F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 26, 2026 |
| Sep 21, 2026 | B | Apt 4F · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CELING IN CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 26, 2026 |
| Sep 21, 2026 | B | Apt 4F · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 26, 2026 |
| Sep 21, 2026 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Dec 25, 2026 |
| Sep 21, 2026 | A | § 27-2022 ADM CODE POST A SIGN INDICATING HOURS OF COLLECTION AND METHOD OF COLLECTION OF WASTE MATERIAL WHERE DUMBWAITER SERVICE IS NOT PROVIDED. AT PUBLIC HALL, 1st STORY | Dec 25, 2026 |
| Apr 22, 2026 | B | Apt 4F · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | May 27, 2026 |
| Apr 22, 2026 | B | Apt 4F · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | May 27, 2026 |
| Apr 22, 2026 | A | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE WALLS AND FLOOR AT PUBLIC HALL, 1st STORY | Jul 26, 2026 |
| Apr 22, 2026 | B | 566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF FLIES AT PUBLIC HALL, 1st STORY | May 27, 2026 |
| Apr 22, 2026 | A | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE STAIRS AT BASEMENT | Jul 26, 2026 |
| Feb 5, 2024 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | Feb 11, 2024 |
| Feb 5, 2024 | C | Apt 2 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 3, 2024 |
| Feb 5, 2024 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 2, 2024 |
| Feb 5, 2024 | B | Apt 2 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 11, 2024 |
| Feb 5, 2024 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 2, 2024 |
| Aug 5, 2020 | B | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR AT MAIL BOX FOR ALL UNITS , 1st STORY | Sep 9, 2020 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 22, 2026 | HPD B | § 27-2050 ADM CODE PROVIDE 3 EXTRA SPRINKLER HEADS AND SUITABLE WRENCH FOR EMERGENCY PURPOSES AT O.S.Y. VALVE OF SPRINKLER IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT AT CELLAR | Open |
| Sep 22, 2026 | HPD B | § 27-2050 ADM CODE SEAL IN OPEN POSITION THE O.S.Y. VALVE OF THE SPRINKLER SYSTEM IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT O.S.Y VALVE NOT SEALED IN OPEN POSITION AT CELLAR | Open |
| Sep 22, 2026 | HPD C | § 27-2005, 2050 HMC: PROVIDE AN ADEQUATE SUPPLY OF WATER FOR THE WET SPRINKLER AND/OR STANDPIPE SYSTEM AT CELLAR | Open |
| Sep 22, 2026 | HPD C | § 27-2005 HMC: IMMEDIATELY PROVIDE A FIRE GUARD AS DIRECTED BY THE NYC DEPT. OF HOUSING PRESERVATION & DEVELOPMENT (HPD) AND/OR THE NYC DEPT. OF BUILDINGS (DOB) TO PROTECT AGAINST FIRE HAZARDS OBSERVED BY HPD AND/OR DOB. FIRE HAZARDS OBSERVED BY HPD HAVE RESULTED IN THE FOLLOWING ADDITIONAL HPD VIOL | Open |
| Sep 21, 2026 | HPD A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Open |
| Sep 21, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT ROOF DOOR AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 4th STORY | Open |
| Sep 21, 2026 | HPD B | § 27-2005 ADM CODE PROVIDE UNLOCKABLE SLIDE BOLT AT NORTH ROOF DOOR THAT ALLOWES RENTRY FROM ROOF TO PUBLIC HALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 4th STORY | Open |
| Sep 21, 2026 | HPD A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME READILY ACCESSIBLE FOR SIGNATURE, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT FRAME MISSING AT PUBLIC HALL, 1st STORY | Open |
| Sep 21, 2026 | HPD A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Open |
| Sep 21, 2026 | HPD C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGNAGE MISSING AT PUBLIC HALL, 1st STORY | Open |
| Sep 21, 2026 | HPD A | §27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS | Open |
| Sep 21, 2026 | HPD A | §27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX SIGNAGE MISSING AT PUBLIC HALL, 1st STORY | Open |
| Sep 21, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 21, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CELING IN CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 21, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 21, 2026 | HPD A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Open |
| Sep 21, 2026 | HPD A | § 27-2022 ADM CODE POST A SIGN INDICATING HOURS OF COLLECTION AND METHOD OF COLLECTION OF WASTE MATERIAL WHERE DUMBWAITER SERVICE IS NOT PROVIDED. AT PUBLIC HALL, 1st STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 3:37 PM ET. BBL 2045460076.