5 floors · 21 apartments · 17,250 sq ft · built 1911 · class C1 · owner of record: Grand Concourse Easthsg Dev Fd Corp.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 46 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 46 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 62 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 290 days | Registered through 2027-09-01 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-18 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 2, 2026 | Construction CLASS - 2 FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39070557Y, FILE A CERTIFICATE OF CORRECTION #39190909P | Aug 21, 2026 IN VIOLATION | $1,250 |
| Sep 21, 2022 | Construction CLASS - 2 WORK W/O A PERMIT. AT TIME OF INSPECTION OBSERVED FULL HEIGHT PARTITIONS CREATING AN ADDITIONAL 2 ROOMS FOR A TOTAL OF 6 ROOMS IN CELLAR APT. UPON REVIEW OF DEPT RECORDS(HPD I CARD) SHOWS 4 ROOMS AND(DOB BIS/DO #35593455K | Dec 16, 2022 DEFAULT | $362 |
| Sep 21, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER-AT TIME OF INSPECTION OBSERVED THAT THE CELLAR APT ENTRY DOOR WAS IN A STATE OF DISREPAIR. APARTMENT ENTRY DOOR IS UNABLE TO OPEN AND CLOSE FREELY CREATING #39070557Y | Nov 18, 2022 DEFAULT | $6,250 |
| Sep 21, 2022 | Construction CLASS - 2 OCCUPANCY CONTRARY TO DEPT RECORDS- AT TIME OF INSPECTION OBSERVED 6 ROOMS LOCATED IN CELLAR APARTMENT. UPON REVIEW OF DEPARTMENT RECORDS THERE SHOULD ONLY BE 4, DISCONTINUE ILLEGAL OCCUPANCY OR AMEND C OF O #39070556M | Nov 18, 2022 DEFAULT | $6,250 |
| Jul 6, 2022 | Boilers CLASS - 2 FOUND EXPOSED WIRING, CORRODED FITTING ON HARTFORD LOOP AT BOILER, DISCHARGE PIPE MISSING AT BOTH BLOW DOWN AT LOW WATER CUT OFF,GLASS GAUGE DIRTY AND MISSING GUARDS, BOILER DOORS MISSING BOLTS AND LATCHES AND #39065275J | Sep 2, 2022 DEFAULT | $3,125 |
| Jul 6, 2022 | Boilers CLASS - 1 CEASE USE FEDERAL FST-40 BOILER, DUE TO WATER COMING OUT OF REAR CHAMBER DOOR, DO NOT OPERATE BOILER TIL ALL HAZARDOUS CONDITIONS ARE CORRECTED AND DOB IS NOTIFIED TO RE INSPECT TO LIFT CEASE USE ORDER. #39065276L | Sep 2, 2022 DEFAULT | $6,250 |
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #15321 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 31, 2023 | I | §27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESULT IN BUILDING-WIDE INSPECTIONS, FEES, AND EXTENSIVE REPAIR WORK TO CORRECT VIOLATIONS AND UNDERLYING CONDITIONS. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WIL | — |
| Nov 5, 2026 | B | Apt 17D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 19062914 ISSUED 07-JUL-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CO | Dec 10, 2026 |
| Oct 5, 2026 | B | Apt 4A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 9, 2026 |
| Oct 5, 2026 | B | Apt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 9, 2026 |
| Oct 5, 2026 | B | Apt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 9, 2026 |
| Oct 5, 2026 | B | Apt 4A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 9, 2026 |
| Oct 5, 2026 | B | Apt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 9, 2026 |
| Oct 5, 2026 | C | Apt 4A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 11, 2026 |
| Oct 5, 2026 | B | Apt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 9, 2026 |
| Oct 5, 2026 | C | Apt 4A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH, AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 11, 2026 |
| Oct 5, 2026 | B | Apt 4A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 9, 2026 |
| Oct 5, 2026 | A | Apt 4A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 3 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 8, 2027 |
| Sep 16, 2026 | A | Apt 17D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ESTUCHEON PLATE AT HEAT RISER TOP IN THE BATHROOM LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Dec 20, 2026 |
| Sep 16, 2026 | B | Apt 17D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE IN THE BATHROOM LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 21, 2026 |
| Sep 16, 2026 | B | Apt 17D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOORING IN THE KITCHEN LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 21, 2026 |
| Sep 16, 2026 | B | Apt 17D · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CONCEALED LEAK AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 21, 2026 |
| Sep 16, 2026 | B | § 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE THE GARBAGE ON THE STAIR PLATFORM AT EAST WALL TO EAST COURTYARD AND FIRE PASSAGEWAY. AT PUBLIC HALL STAIRS | Oct 21, 2026 |
| Sep 16, 2026 | A | Apt 17D · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Dec 20, 2026 |
| Jul 31, 2026 | B | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE THE OBSTRUCTION IN FIREPROOF PASSAGEWAY GARBAGE BAGS AT EAST YARD STAIRS TO FIRE PASSAGEWAY YARD, 1st STORY | Sep 4, 2026 |
| Jul 13, 2026 | C | Apt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 19, 2026 |
| Jul 13, 2026 | C | Apt 2A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH FIRE ESCAPE WINDOW IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 19, 2026 |
| Jul 13, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AT PUBLIC HALL STAIRS, 4th STORY | Oct 16, 2026 |
| Jul 13, 2026 | B | Apt 2A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 17, 2026 |
| Jul 13, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Jul 19, 2026 |
| Jul 13, 2026 | A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT AT WALLS AT PUBLIC HALL STAIRS, 4th STORY | Oct 16, 2026 |
| Jul 10, 2026 | B | Apt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 2A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT BOTTOM SASH IN THE 5th ROOM FROM NORTH AT WEST LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND SOUTH WALL IN THE 5th ROOM FROM EAST AT NORTH LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WEST WALL IN THE ENTRANCE LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 14, 2026 |
| Jul 10, 2026 | C | Apt 2A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 5, 2026 |
| Jul 10, 2026 | C | Apt 2A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 16, 2026 |
| Jul 10, 2026 | B | Apt 2A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 2A · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASHBASIN WASTE LINE IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 14, 2026 |
| Jul 8, 2026 | C | Apt 17D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR UNKEYED PLASTER AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 14, 2026 |
| Jul 8, 2026 | B | Apt 17D · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 12, 2026 |
| Jul 8, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT PUBLIC HALL, 1st STORY | Jul 14, 2026 |
| Jul 7, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCK AT BOILER ROOM | Jul 13, 2026 |
| Jun 30, 2026 | C | Apt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 6, 2026 |
| Jun 30, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Jul 6, 2026 |
| Jun 30, 2026 | B | Apt 2A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 4, 2026 |
| Jun 26, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR AT BOILER ROOM | Jul 2, 2026 |
| Jun 26, 2026 | C | Apt 15D · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 15D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Jun 25, 2026 |
| Jun 22, 2026 | C | Apt 2A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2026 |
| Jun 22, 2026 | B | Apt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 27, 2026 |
| Jun 22, 2026 | C | Apt 2A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2026 |
| Jun 22, 2026 | C | Apt 2A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRINGS BALANCES AT EMERGENCY EXIT WINDOW LOWER SASH IN THE 5th ROOM FROM NORTH LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2026 |
| Jun 22, 2026 | C | Apt 2A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 18, 2026 |
| Jun 22, 2026 | B | Apt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 27, 2026 |
| Jun 22, 2026 | C | Apt 2A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2026 |
| Jun 22, 2026 | B | Apt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 27, 2026 |
| Jun 22, 2026 | C | Apt 2A · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE PIPE UNDER THE SINK IN THE BATHROOM LOCATED AT APT 2A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2026 |
| Apr 30, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 3, 2026 |
| Dec 9, 2025 | B | Apt 15D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM LOCATED AT APT 15D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jan 13, 2026 |
| Dec 9, 2025 | A | Apt 15D · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 15D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 14, 2026 |
| Dec 9, 2025 | B | Apt 15D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 15D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jan 13, 2026 |
| Dec 9, 2025 | A | Apt 15D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 15D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 14, 2026 |
| Dec 9, 2025 | B | Apt 15D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH IN THE 4th ROOM FROM NORTH LOCATED AT APT 15D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jan 13, 2026 |
| Dec 9, 2025 | C | Apt 19E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 19E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jan 4, 2026 |
| Dec 9, 2025 | B | Apt 19E · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN IN THE BATHROOM LOCATED AT APT 19E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jan 13, 2026 |
Showing 60 of 179. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Nov 5, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 19062914 ISSUED 07-JUL-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CO | Open |
| Oct 5, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD C | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH, AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 3 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 4A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Sep 16, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ESTUCHEON PLATE AT HEAT RISER TOP IN THE BATHROOM LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Sep 16, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE IN THE BATHROOM LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Sep 16, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOORING IN THE KITCHEN LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Sep 16, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CONCEALED LEAK AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Sep 16, 2026 | HPD B | § 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE THE GARBAGE ON THE STAIR PLATFORM AT EAST WALL TO EAST COURTYARD AND FIRE PASSAGEWAY. AT PUBLIC HALL STAIRS | Open |
| Sep 16, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 17D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Jul 31, 2026 | HPD B | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE THE OBSTRUCTION IN FIREPROOF PASSAGEWAY GARBAGE BAGS AT EAST YARD STAIRS TO FIRE PASSAGEWAY YARD, 1st STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 15, 2026, 12:40 PM ET. BBL 2024220052.