Manhattan · Block 579 · Lot 7501 · 10013

290 Hudson Street

6 floors · 5 apartments · 24,533 sq ft · built 1900 · class RM · owner of record: Connection Partners Llc

16open violations
$40,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 61 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 61 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 77 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1157 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-22 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (11) · $40,000 owed
IssuedViolationHearingBalance
Apr 20, 2026Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #917224. REMEDY: FILE ACCEPTABLE REPORT.
#37036690L
Jul 1, 2027
DEFAULT
$6,250
Feb 27, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED INSTALLED AT EXPO# 1-4 MISSING PROJECT INFORMATION PANEL CONTRARY TO BC 3301.9.2. CREATING UNSAFE CONDITIONS FOR PUBLIC AND OCCUPIED ADJOINING PROPERTIES, SAFETY MO
#39551017K
May 7, 2026
ADMIT/IN-VIO
$0
Feb 27, 2026Unknown CLASS - 2
AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED IN PLACE AT EXPOSURE# 1-4 WITH PERMIT# M08000116-I1-SH UPON REVIEW DEPARTMENT RECORD IT APPEAR PERMIT EXPIRED ON 10/17/2025, CREATING AN UNSAFE CONDITION, NO SUPERV
#39551015R
May 7, 2026
ADMIT/IN-VIO
$0
Feb 27, 2026Construction CLASS - 2
RESPONDING TO A COMPLAINT OBSERVED: SIDEWALK SHED INSTALLED AT EXPO# 4. HUDSON STREET SIDE. NO UNDERSIDE LIGHTING INOPERABLE LIGHT BULBS, FAILURE TO MAINTAIN AS PER CODE 3307.6.4.8 BECOME AN UNSAFE AND HAZARDOU
#39551016Z
May 7, 2026
ADMIT/IN-VIO
$0
Jan 20, 2026Unknown CLASS - 2
SIDEWALK SHED PERMIT EXPIRED. REMEDY: RENEW SIDEWALK SHED PERMIT.
#35718599X
Apr 30, 2026
ADMIT/IN-VIO
$0
Jun 13, 2023Construction CLASS - 1
AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE #1 WITH INOPERABLE LIGHT BULBS UNDERSIDE THE SHED TO BRING ILLUMINATION FAILURE TO PROVIDE LIGHTING CREATES UNSAFE AND MUGGING CONDITION TO
#39517749R
Oct 3, 2024
IN VIOLATION
$2,500
Dec 21, 2022Construction CLASS - 1
UNLAWFUL ACTS FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTE:AT THE TIME OF INSPECTION OBSERVED THAT RESPONDENT FAILURE TO COMPLY PREVIOUSISSUED VIOLATION ECB#35664514R AND 35664515Z DATED 10/24/2022 WHICH ST
#35669565J
Jul 9, 2024
IN VIOLATION
$6,250
Oct 24, 2022Construction CLASS - 1
UNLAWFUL ACTS.FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER.NOTE AT THE TIME OF INSPECTION OBSERVED THAT RESPONDENT FAILED TO COMPLY PREVIOUSLY ISSUED ECB VIO#35564178R AND 35664179Z DATED 9/9/2022 WHICH STAT
#35664514R
Jul 9, 2024
IN VIOLATION
$2,500
Oct 24, 2022Construction CLASS - 1
FAILURE TO TAKE REQUIRED MEASURES TO SECURE PUBLIC SAFETY-UNSAFE FACADE.NOTED QEWI FILED UNSAFE TECHNICAL REPORT#917224 DATED ON 9/2/2022.ASOF TODAY 10/24/2022,INADEQUATE SAFETY MEASURES PLACE SIDEWALK SHED NEE
#35664515Z
Jul 9, 2024
IN VIOLATION
$10,000
Sep 9, 2022Construction CLASS - 1
FAILURE TO PROVIDE REQUIRED SAFETY MEASURES TO PROTECT PUBLIC SAFETY FROM DOC UNSAFE FACADE.NOTE:QEWI FILED FROM UNSAFE TECH REPORT917224 DATED9/2/22&AS OF TODAY9/9/22,NO SAFETY MEASURES IN PLACE TO PROTECT PUB
#35664178R
May 11, 2023
IN VIOLATION
$10,000
Sep 9, 2022Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BLDG FACADE/WALLS&APPURTENANCES.NOTE:EXP2E ELEVATION:STEP CRACK@PARAPET WALLS.EXP1N ELEVATION:STEP CRACKS@PARAPET WALLS,MISSING/ERODED BRICKS@MULTIPLE LOCATIONS,ALSO DAMAGED WINDOWS
#35664179Z
May 11, 2023
IN VIOLATION
$2,500
DOB (5)
IssuedViolationStatus
Jan 20, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS PER SECTION 28.301.1 OF THE NYC ADMIN COE. OBSERVED CRACKED & LOOSE MORTAR JOINTS AT EXPOSURE 1, VERTICALS CRACKS AND DAMAGED AND SPALLING BRICKWORK THROUGHOUT EXPOSURE 3 AND 4. REMEDY: REPAIR AND OR REPLACE
#SR0203BB
DOB VIOLATION - ACTIVE
Jun 13, 2023CONSTRUCTION
FAILURE TO MAINTAIN AND PROTECT PUBLIC WITH ACCEPTABLE SAFETY MEASURES NOTE:BLDG.FILED UNSAFE 9 CYCLE REPORT&OWNER FAILED TO PROV.ACCEPTABLE MEASURES TO PROTECT SAFETY OF PUBLIC AT EXPO#1,3&4@ OPEN PARKING AREAS @NORTH,WEST&SO.LOT OF THE BLDGE.NO ACCEPTABLE METHOD OF PROTECT.REMEDY IMMED.CORRECT OPE
#FA10201MK
DOB VIOLATION - ACTIVE
Sep 9, 2022CONSTRUCTION
EMERGENCY WORK ORDER DUE TO OBSERVE AT EXP2, EAST ELEV: STEP CRACK AT PARAPET WALL AT 7FL. EXP1 NORTH ELEV: STEP CRACKS AT PARAPET WALLS/ BRICK WALL/MISSING ERODED BRICKS/DAMAGED WINDOW LINTEL/DAMAGED MASONRY AT MULTIPLE LOCATIONS, EXP3 SOUTH ELEV DAMAGED MASONRY AT MULTIPLE LOCATIONS. REMEDY: MAKED
#FA0601JM
DOB VIOLATION - ACTIVE
Sep 2, 2022HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#910468
DOB VIOLATION - ACTIVE
Jun 15, 2021CONSTRUCTION
OBSERVED SEVERAL CRACKS ON CONCRETE FLOOR/WALL IN CELLAR & 1ST FLOOR LEVEL & ELEVATOR MACHINE ROOM WITH CRACK METERS ON THE CRACKS. ALSO OBSERVED EXTERIOR VERTICAL CRACK LINES ON BRICK FACADE AT EXPO # 03 & 04. AVERAGE WIDTH OF THE CRACKS 1/8" TO 1/4". AN NB JOB SITE ( 304 HUDSON ST.) ACROSS THE STR
#21-00590
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Sep 2, 2022Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 31, 2026, 10:43 PM ET. BBL 1005797501.

Look up another building