Bronx · Block 3273 · Lot 114 · 10458

2846 Webster Avenue

2 floors · 28,200 sq ft · built 1920 · class G1 · owner of record: J & S Tellerman

9open violations
$6,875ECB/OATH penalties owed
0HPD class C (immediately hazardous)
187dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 28,200 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029

Open violations

ECB / OATH (6) · $6,875 owed
IssuedViolationHearingBalance
Apr 2, 2026Construction CLASS - 2
AS OF APRIL 2, 2026 NO FINAL INSPECTION HAS BEEN FILE FOR THE PERMIT# 220388328 (EXPIRED: 06/01/2015)., CONDUCT/FILE FINAL INSPECTION
#39182935Z
Jul 17, 2026
DEFAULT
$6,250
Oct 1, 2024Construction CLASS - 1
FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMENTING THE CONDITIONS OF PSID#X0000456 BY THE AUGUST 1,2024 DEADLINE.TO DATE,THE DEPARTMENT HAS
#37029628P
Sep 15, 2025
IN VIOLATION
$625
May 3, 2023Construction CLASS - 2
AT THE ACTIVE PARKING GARAGE CONCRETE STRUCTURE, OBSERVED IN THE STATE OF DISREPAIR WITH VERTICAL CRACKS AT THE WALL AND AT THE LOAD BEARING CONCRETE BEAMS, COLUMN, SPALLING CONCRETE AND EXPOSED STEEL REINFORCE
#39085417Y
Aug 4, 2023
IN VIOLATION
$0
Oct 12, 2018Construction CLASS - 2
WORK W/O A PERMIT. AT TIME OF INSPECTION NOTED REAR WALL AT EXP#3 WAS REMOVED,WALL IS AROUND 140FEET LONG X 20FEET HIGH. NO PERMITS ON FILE W/DOB REAR WALL HAS TARPS COVERING THE OPENING. REMEDY: OBTAIN ALL PER
#35305563Z
Jan 18, 2019
IN VIOLATION
$0
Dec 16, 2014Construction CLASS - 2
FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOBSITE @ TIME OF INSP.ALT.II.JOB #220388328 FOR INSTALLATION OF CAR LIFT @ 1ST + 2ND FLOOR HAS AN ACTIVE PERMIT TILL 6-1-15.NO PLANS FOR THIS ACTIVE JOB HOLE AVAIL
#35110690L
Jan 30, 2015
IN VIOLATION
$0
Jan 18, 2014Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT 1ST STY 1)CONCRETE CEILING SPALLING W/EXPOSED RUSTED REBAR VARIOUS LOCATIONS THROUGHOUT. 2)CONCRETE F.P.C. CRACKED/SPALLING FROM STEEL BEAMS. REMEDY: REPAIR
#35084877P
May 16, 2014
IN VIOLATION
$0
DOB (3)
IssuedViolationStatus
Mar 14, 2022CONSTRUCTION
FTM BLDG IN SAFE CONDITION:ON 3/14/2022 CEU PERFORMED INSPECTION ON 1ST AND 2ND FLOOR. OBSERVED EXP3 CONCRETE ENCASED STEEL BEAM EXCESS DEFLECTION AND WATER DAMAGE AT POCKET LOCATIONS. GARAGE RAMP OPENING AT EXP2. REMEDY: OWNER TO IMMED RETAIN NYS PE TO EVALUATE EXP4 BEAN AND EXP2 GARAGE RAMP. PROVI
#CEU20702ZT
DOB VIOLATION - ACTIVE
Oct 22, 2021CONSTRUCTION
FTM BUILDING IN SAFE CONDITION..ON 10/6/2021 CEU PERFORMED VISUAL INSPECTION FROM GRADE. CEU OBSERVED EXP2 WALL PARTIAL COLLAPSE REMEDY: OWNER TO IMMED RETAIN NYS PE TO EVALUATE EXP2 WALL REPAIR EXP 2 WALL PER NYS PE INSTRUCTIONS. PROVIDE REPORT UPON COMPLETION OF REPAIR WORK. FILE DRAWINGS AND PERM
#CEU20701ZT
DOB VIOLATION - ACTIVE
Jul 28, 2003CONSTRUCTION

#074FG
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 6:22 AM ET. BBL 2032730114.

Look up another building