2 floors · 28,200 sq ft · built 1920 · class G1 · owner of record: J & S Tellerman
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 28,200 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 2, 2026 | Construction CLASS - 2 AS OF APRIL 2, 2026 NO FINAL INSPECTION HAS BEEN FILE FOR THE PERMIT# 220388328 (EXPIRED: 06/01/2015)., CONDUCT/FILE FINAL INSPECTION #39182935Z | Jul 17, 2026 DEFAULT | $6,250 |
| Oct 1, 2024 | Construction CLASS - 1 FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMENTING THE CONDITIONS OF PSID#X0000456 BY THE AUGUST 1,2024 DEADLINE.TO DATE,THE DEPARTMENT HAS #37029628P | Sep 15, 2025 IN VIOLATION | $625 |
| May 3, 2023 | Construction CLASS - 2 AT THE ACTIVE PARKING GARAGE CONCRETE STRUCTURE, OBSERVED IN THE STATE OF DISREPAIR WITH VERTICAL CRACKS AT THE WALL AND AT THE LOAD BEARING CONCRETE BEAMS, COLUMN, SPALLING CONCRETE AND EXPOSED STEEL REINFORCE #39085417Y | Aug 4, 2023 IN VIOLATION | $0 |
| Oct 12, 2018 | Construction CLASS - 2 WORK W/O A PERMIT. AT TIME OF INSPECTION NOTED REAR WALL AT EXP#3 WAS REMOVED,WALL IS AROUND 140FEET LONG X 20FEET HIGH. NO PERMITS ON FILE W/DOB REAR WALL HAS TARPS COVERING THE OPENING. REMEDY: OBTAIN ALL PER #35305563Z | Jan 18, 2019 IN VIOLATION | $0 |
| Dec 16, 2014 | Construction CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOBSITE @ TIME OF INSP.ALT.II.JOB #220388328 FOR INSTALLATION OF CAR LIFT @ 1ST + 2ND FLOOR HAS AN ACTIVE PERMIT TILL 6-1-15.NO PLANS FOR THIS ACTIVE JOB HOLE AVAIL #35110690L | Jan 30, 2015 IN VIOLATION | $0 |
| Jan 18, 2014 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT 1ST STY 1)CONCRETE CEILING SPALLING W/EXPOSED RUSTED REBAR VARIOUS LOCATIONS THROUGHOUT. 2)CONCRETE F.P.C. CRACKED/SPALLING FROM STEEL BEAMS. REMEDY: REPAIR #35084877P | May 16, 2014 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 14, 2022 | CONSTRUCTION FTM BLDG IN SAFE CONDITION:ON 3/14/2022 CEU PERFORMED INSPECTION ON 1ST AND 2ND FLOOR. OBSERVED EXP3 CONCRETE ENCASED STEEL BEAM EXCESS DEFLECTION AND WATER DAMAGE AT POCKET LOCATIONS. GARAGE RAMP OPENING AT EXP2. REMEDY: OWNER TO IMMED RETAIN NYS PE TO EVALUATE EXP4 BEAN AND EXP2 GARAGE RAMP. PROVI #CEU20702ZT | DOB VIOLATION - ACTIVE |
| Oct 22, 2021 | CONSTRUCTION FTM BUILDING IN SAFE CONDITION..ON 10/6/2021 CEU PERFORMED VISUAL INSPECTION FROM GRADE. CEU OBSERVED EXP2 WALL PARTIAL COLLAPSE REMEDY: OWNER TO IMMED RETAIN NYS PE TO EVALUATE EXP2 WALL REPAIR EXP 2 WALL PER NYS PE INSTRUCTIONS. PROVIDE REPORT UPON COMPLETION OF REPAIR WORK. FILE DRAWINGS AND PERM #CEU20701ZT | DOB VIOLATION - ACTIVE |
| Jul 28, 2003 | CONSTRUCTION #074FG | DOB VIOLATION - ACTIVE |