6 floors · 23,530 sq ft · built 1975 · class N2 · owner of record: Nyc Department Of Homeless Services
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 775 days | Next cycle year 2028 |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-07 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 23, 2025 | Construction CLASS - 2 OBSERVED IN BASEMENT DAMAGED SPRINKLER HEAD; THE DOOR OPENS INTO SPRINKLER LINE, AND THE DRAIN LINE IS IN THE DEDICATED ELECTRICAL ROOM WHICH CONTRARY TO CODE SECTION BC 101.4.5, REPAIR AND/OR REPLACE #39171289J | Feb 6, 2026 POP/IN-VIO | $0 |
| Dec 23, 2025 | Boilers CLASS - 2 FOUND WEIL MCLAIN(MODEL# 588 DUAL FUEL BOILER NOT REGISTERED CORRECT VIOLATING CONDITION SUBMIT CERTIFICATE OF CORRECTION #39171251Y | Dec 24, 2025 POP/IN-VIO | $0 |
| Dec 23, 2025 | Boilers CLASS - 2 FOUND WEIL MCLAIN(MODEL# 588) DUAL FUEL BOILER NOT REGISTERED, CORRECT VIOLATING CONDITION SUBMIT CERTIFICATE OF CORRECTION #39171248N | Dec 24, 2025 POP/IN-VIO | $0 |
| Dec 23, 2025 | Construction CLASS - 2 OBSERVED OBSTRUCTED SPRINKLER HEADS THROUGHOUT THE BUILDING, MISSING INSULATION ON BATHROOM TRAPS, LACK OF FIRESTOPPING AROUND SPRINKLER LINE ON THE 6TH FLOOR STAIRWELL A , AND A LEAKING SINK WASTE LINE ON FIST #39171288H | Dec 24, 2025 POP/IN-VIO | $0 |
| Dec 23, 2025 | Boilers CLASS - 2 FOUND A O SMITH (MODEL#HW 670) GAS FIRED BOILER NOT REGISTERED CORRECT VIOLATING CONDITION SUBMIT CERTIFICATE OF CORRECTION #39171291Z | Dec 24, 2025 POP/IN-VIO | $0 |
| Dec 9, 2022 | Boilers CLASS - 2 AS PER ONE, NATURAL GAS BURNING, WEIL MCLAIN, HOT WATER BOILER, MODEL 588 SERIES 1, BOILER NO. 100473-02; BOILER NOT REGISTERED AS PER DOB RECORDS; REGISTER BOILER AND CALL FOR AN INSPECTION. #39075412X | Jan 11, 2023 POP/IN-VIO | $0 |
| Dec 9, 2022 | Boilers CLASS - 2 AS PER ONE NATURAL GAS BURNING, HOT WATER BOILER MODEL 588 SERIES 1, BOILER NO. 100473-01. BOILER NOT REGISTERED AS PER DOB RECORDS; REGISTER BOILER AND CALL FOR AN INSPECTION. #39075413H | Jan 11, 2023 POP/IN-VIO | $0 |
| Dec 9, 2022 | Boilers CLASS - 2 AS PER ONE NATURAL GAS BURNING, AO SMITH DOMESTIC HOT WATER BOILER. MODEL NO. HW-670 200, SERIAL NO. 1937M000013; BOILER NOT REGISTERED AS PER DOB RECORDS. #39075411Y | Jan 11, 2023 POP/IN-VIO | $0 |
| Dec 5, 2022 | Construction CLASS - 2 OBSERVED: FROM FIRST FLOOR TO 6TH FLOOR, MECHANICAL ROOM, GAS METER/GENERATOR RMS, EXPOSED STEEL STRUCTURE (COLUMNS, GIRDERS, TRUSSES, BEAMS,) IS REQUIREMENTS FOR STRUCTURAL MEMBERS AND ASSEMBLIES TO BE FIRE PR #39075114H | Dec 8, 2022 POP/IN-VIO | $0 |
| Dec 5, 2022 | Construction CLASS - 2 OBSERVED: AT SECOND FLOOR, TERRACE, CONCRETE TILES ARE SPLIT /CRACKED AND DETERIORATED., REPAIR AND/OR REPLACE #39075113X | Dec 8, 2022 POP/IN-VIO | $0 |
| Nov 23, 2021 | Construction CLASS - 2 NOTED: OBSERVED PIPES AND ELECTRICAL CONDUITS PENETRATING THROUGH EACH FLOOR AND CEILING WITHIN ALL AC ROOMS WITH NO FIRE STOPPING PROVIDED., PROVIDE/MAINTAIN FIRE STOPPING #39051619R | Dec 13, 2021 POP/IN-VIO | $0 |
| Dec 16, 2019 | Construction CLASS - 1 28-104.8.4 INADEQUATE TENANT PROTECTION PLAN. NOTED:AT TIME OF INSPECTION READING THE TPP SECTION 3:DOES NOT SAY THE METHODS TO BE USED FOR DUST CONTROL AND IN SECTION 6:DOES NOT SAY THE HOURS AND DAY THEY WILL #35416632P | Feb 20, 2020 DEFAULT | $6,250 |
| May 18, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3 27-345. NOTED: AT CELLAR LEVEL SECTION OF WALL MISSING ABOVE DOOR AND HOLES IN CEILING AND WALLS. THAT WERE NOT FIRE STOPPED #35331808R | Aug 2, 2018 POP/IN-VIO | $0 |
| Apr 27, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING CODE COMPLIANT MANNER. I OBSERVED IN CELLAR GAS METER AND GAS PIPING INSTALLED IN THE SAME ROOM AS THE FIREPUMP WHICH IS CONTRARY TO THE REQUIREMENTS OF THE NFPA AS ADOPTED BY #35329498H | Jun 28, 2018 POP/IN-VIO | $0 |
| Aug 31, 2017 | Plumbing CLASS - 1 404.1 GAS PIPING PROHIBITED LOCATION-FIRE PUMP ROOM.OBSERVED ON 8/31/17 AT ABOVE ADDRESS GAS METER IS LOCATED IN TEH FIRE PUMP ROOM. REMEDY:COMPLY WITH SUMMONS. #35290533Z | Dec 14, 2017 POP/IN-VIO | $0 |
| Mar 21, 2017 | Plumbing CLASS - 1 GAS PIPING IN A PROHIBITED LOCATION-FIRE PUMP ROOM OBSERVED ON 3/21/17GAS PIPING INSTALLED IN FIRE PUMP ROOM. RMDY: COMPLY WITH SUMMONS. PHOTOS TAKEN. #35235728R | Apr 27, 2017 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
None open.