| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 68 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 68 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 84 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 76,807 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 189 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 189 days | Annual filing |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1297). Agency page | Dec 31, 2027 in 433 days | Next due 2027 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-09 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Dec 6, 2005 | ELEVATOR #90113148968 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Dec 6, 2005 | ELEVATOR #90113148969 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 6, 2026 | Energy Grade - LL33 FTP-EN-EGRDEA FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3 | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 12, 2026 | B | Apt 4L · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT LESS THAN 10 SQFT CEILING IN THE BATHROOM LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' ORIGINAL VIOLATION 18636745 ISSUED 11-FEB-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTR | Jul 17, 2026 |
| Jun 12, 2026 | B | Apt 4L · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT ,LESS THAN 10 SQFT , WINDOW FRAME FROM EAST AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' ORIGINAL VIOLATION 18636744 ISSUED 11-FEB-26 HAS BEEN U | Jul 17, 2026 |
| Mar 27, 2026 | A | Apt 4L · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 2nd WINDOW FRAME FROM EAST AT SOUTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | Jun 30, 2026 |
| Mar 27, 2026 | A | Apt 4L · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | Jun 30, 2026 |
| Mar 27, 2026 | A | Apt 4L · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE FOYER LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | Jun 30, 2026 |
| Mar 27, 2026 | A | Apt 4L · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FRAME FROM SOUTH AT WEST WALL, 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | Jun 30, 2026 |
| Mar 18, 2026 | C | Apt 4K · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR LEADING TO FIRE ESCAPE IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4K, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Mar 24, 2026 |
| Feb 12, 2026 | B | Apt 4L · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD DOOR AT, ENTRANCE DOOR, NORTH WALL, IN THE BATHROOM LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | Mar 19, 2026 |
| Feb 12, 2026 | B | Apt 4L · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | Mar 19, 2026 |
| Feb 12, 2026 | A | Apt 4L · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FRAME FROM SOUTH AT WEST WALL, 1st RADIATOR FROM NORTH AT EAST WALL, 1st RISER FROM EAST AT SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | May 18, 2026 |
| Feb 12, 2026 | A | Apt 4L · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT SOUTH WALL, BASEBOARD AT SOUTH WALL, NORTH WALL, 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | May 18, 2026 |
| Feb 12, 2026 | A | Apt 4L · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION AT 1st RADIATOR FROM EAST AT SOUTH WALL, 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | May 18, 2026 |
| Feb 12, 2026 | B | Apt 4L · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | Mar 19, 2026 |
| Feb 12, 2026 | C | Apt 4L · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2, WG TO REPLACE = 0, WG TO REPAIR = 1 IN THE ENTIRE APARTMENT LOCATED AT APT 4L, 4th STORY, 1st APAR | Mar 10, 2026 |
| Feb 12, 2026 | B | Apt 4L · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SINK' S COUNTERTOP , AT EAST WALL , IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | Mar 19, 2026 |
| Feb 12, 2026 | A | Apt 4L · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RISER FROM SOUTH AT WEST WALL IN THE BATHROOM LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | May 18, 2026 |
| Feb 12, 2026 | B | Apt 4L · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | Mar 19, 2026 |
| Feb 12, 2026 | A | Apt 4L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | May 18, 2026 |
| Feb 12, 2026 | A | Apt 4L · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL, NORTH WALL, EAST WALL, CEILING IN THE 4th ROOM FROM EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | May 18, 2026 |
| Feb 12, 2026 | A | Apt 4L · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION AT 1st RISER FROM SOUTH AT WEST WALL IN THE BATHROOM LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' | May 18, 2026 |
| May 6, 2025 | B | Apt 4K · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 4K, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 17595967 ISSUED 04-JAN-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017 | Jun 10, 2025 |
| Mar 11, 2024 | B | Apt 5H · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT UPPER RISER IN THE KITCHEN LOCATED AT APT 5H , 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Apr 15, 2024 |
| Oct 11, 2022 | B | Apt 6C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT ( APPROXIMATELY 25 SQFT) CEILING IN THE BATHROOM LOCATED AT APT 6C, 6th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Nov 15, 2022 |
| Nov 4, 2021 | A | Apt 5C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SUSPENDED ACOUSTIC TILES AT CEILING IN THE KITCHEN LOCATED AT APT 5C, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST | Feb 7, 2022 |
| Apr 30, 2019 | C | Apt 4K · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4K, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | May 21, 2019 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 8:51 PM ET. BBL 3012970006.