5 floors · 680 apartments · 277,000 sq ft · built 1929 · class C1 · owner of record: Hp Bronx Park East Housing Dvlp Fund Com Pany, Inc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Energy audit and retro-commissioning (2026) Likely applies Local Law 87 · Calendar year 2026 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4506). Agency page | Dec 31, 2026 in 58 days | Due this year |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 277,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 302 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 423 days | Next cycle year 2027 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-06 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 10, 2026 | Unknown CLASS - 2 EXPIRED SHED PERMIT. OBSERVED THE FOLLOWING SIDE WALK SHED PERMIT #X01065752-I1-SH EXPIRED ON 07/07/2026 AND NO PERMIT POSTED ON DATABASE. REMEDY: RENEW PERMIT. #35730747K | Jan 15, 2027 PENDING | $1,250 |
| Aug 10, 2026 | Unknown CLASS - 2 EXPIRED SHED PERMIT. OBSERVED THE FOLLOWING SIDE WALK SHED PERMIT #X0106598-I1-SH EXPIRED ON 07/07/2026 AND NO PERMIT POSTED ON DATABASE. REMEDY: RENEW PERMIT. #35730745R | Jan 15, 2027 STIPULATION/IN-VIO | $0 |
| Aug 10, 2026 | Unknown CLASS - 2 EXPIRED SHED PERMIT. OBSERVED THE FOLLOWING SIDE WALK SHED PERMIT #X0007639-I1-SH EXPIRED ON 7/07/2026 AND NO PERMIT POSTED ON DATA BASE. REMEDY: RENEW PERMIT. #35730744P | Jan 15, 2027 STIPULATION/IN-VIO | $620 |
| Aug 10, 2026 | Unknown CLASS - 2 EXPIRED SHED PERMIT. OBSERVED THE FOLLOWING SIDE WALK SHED PERMIT #X0106342-I1-SH EXPIRED ON 07/07/2026 AND NO PERMIT POSTED ON DATABASE. REMEDY: RENEW PERMIT. #35730746Z | Jan 15, 2027 PENDING | $1,250 |
| May 13, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIMES OF INSPECTION, NO ACCESS NO CERTIFICATE OF CORRECTION ON FILE. FAILURE TO CERTIFY C #39188501Z | Aug 7, 2026 IN VIOLATION | $1,250 |
| Jan 30, 2025 | Construction CLASS - 2 OBSERVED IN APARTMENT # J23(BLDG. # 2819) PART OF THE KITCHEN AREA WAS CONVERTED INTO SLEEPING AREA WITH BED, CLOTHING & PERSONAL ITEMS., DISCONTINUE ILLEGAL OCCUPANCY OR AMEND C OF O #39136991X | Apr 18, 2025 STIPULATION/IN-VIO | $630 |
| Oct 17, 2024 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. NOTE: AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED IN PLACE OBSERVED MISSING CROSS BRACE/NO VERTICAL NETTING INSTALLED AT PLACES WHERE SHED IN NOT LOCATE #35686497L | Jun 27, 2025 IN VIOLATION | $2,400 |
| Oct 17, 2024 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. MOTE: AT TIMEOF INSPECTION, OBSERVED NO VERTICAL INSTALLED ON SIDEWALK SHED WHERE SHED WAS NOT NEAR FACADE. REMEDY: COMPLY WITH CODE. #35686496J | Jun 27, 2025 IN VIOLATION | $2,400 |
| Oct 16, 2024 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE: AT TIME OF INSPECTION, OBSERVED MULTIPLE FIRE ESCAPE PASSAGEWAY BLOCKED BY BRICKS THAT FELL ON FIRE ESCAPE AND MULTIPLE AREAS OF GARBAGE AND FLOWER POTS. R #35686494X | Dec 20, 2024 IN VIOLATION | $312 |
| Oct 16, 2024 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE: AT TIMEOF INSPECTION, OBSERVED SIDEWALK SHED IN PLACE. OBSERVED AREAS WHERE SHED DOES NOT TOUCH FACADE/OPEN AREAS TO WALK UNDER HAZARDOUS CONDITION #35686495H | Dec 20, 2024 IN VIOLATION | $2,400 |
| Jun 7, 2024 | Construction CLASS - 2 SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS CODE SPECIFICATIONS. NOTE AT TIME OF INSPECTION, OBSERVED SHED IN PLACE WITH NO SAFETY NETTING INSTALLED AROUND THE SHED LEAVING HAZARD. INTALL NETTING WHERE SHED #35685356N | Aug 16, 2024 IN VIOLATION | $2,400 |
| Jun 7, 2024 | Construction CLASS - 2 SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. NOTE AT TIME OF INSPECTION, OBSERVED SHED IN PLACE WITH NO SAFETY NETTING INSTALLED AROUND SHED LEAVING HAZARD. INSTAL NETTING WHERE SHED IS NOT CLOSE TO FACADE #35685357P | Jul 28, 2025 IN VIOLATION | $2,400 |
| Apr 17, 2024 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED APT # U54 AND STAIR BULKHEAD INSTATE OF DISREPAIR CONDITIONS WITH WATER DAMAGED, PAINT BUBBLE, CRACKS AND PLYWOOD COVERED ON CEILING & WALL. ALSO OBSERVED WATER ACCUMULATION ON RO #39111926Z | May 2, 2025 IN VIOLATION | $1,250 |
| Dec 12, 2023 | Unknown CLASS - 2 SUMMONS ISSUED FOR FAILURE TO OBTAIN PERMIT PRIOR TO INSTALLATION/ USE OF SIDEWALK SHED. SIDEWALK SHED PERMIT EXPIRED 08/23, OBTAIN A PERMIT #39101252M | Mar 15, 2024 IN VIOLATION | $1,250 |
| May 5, 2023 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT APARTMENT Y53 ON 5TH FL., SEVERE WATER DAMAGE TO CEILINGS & WALLS WITH PLASTER/DRYWALL COMPLETELY SATURATED WITH WATER. S #39085606N | Jun 7, 2024 IN VIOLATION | $0 |
| Oct 30, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: OBSERVED ON ROOF, REAR OF BUILDING AT PARAPET, DECORATIVE STONE IS SPALLING, CRACKED AND MISSING PIECES/FALLEN PIECES OF WHICH SOME PIECES ARE AND H #35294293R | Mar 16, 2018 IN VIOLATION | $0 |
| Oct 30, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: AT EXPOSURES #1 & 3, AT PARAPET WALL LEVEL, DECORATIVE COLUMNS HAVE CRACKED LOOSE AND MISSING BRICKS. ALSO MISSING MORTAR IN SAME AREA. ALSO AT EXPO #35296877J | Mar 28, 2018 IN VIOLATION | $0 |
| Oct 24, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.NOTED:AT EXPO#1 NORTH-WEST SECTION,PARAPET WALL LEANING INWARD TOWARDS ROOF ALSO AT EXPO1 PARAPET WALL BRICKS CRACKED,LOOSE AND MISSING MORTAR.REM:MAINTAIN BL #35294368M | Mar 16, 2018 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 10, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED THE FOLLOWING CONDITIONS AT ALL VIEW EXPOSURES:CRACKS/STEP CRACKS/CRACK GLASS PANE,MISSING BRICKS DAMAGED JOINTS AND SPALLING BRICKS. REMEDY: REPAIR AND/OR REPLACE #SR1103NS | DOB VIOLATION - ACTIVE |
| Aug 10, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT.OBSERVED AT ALL EXPOSURES: LOOSE BRICKS,BOWED LINTELS,MISSING BRICKS,BROKEN GLASS PANEL @ ENTRANCE DOOR. DAMAGED JOINTS AND SPALLING. NOTE: PARAPET OBSERVED MULTIPLE DEFECTS. REMEDY: REPAIR AND/OR REPLACE #SR1104NS | DOB VIOLATION - ACTIVE |
| Aug 10, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COPLIANT MANNER. OBSERVED THE FOLLOWING CONDITIONS:EXP1 BRKN WINDOW PANE, 5FL LOOSE BRICKS, DAMAGED JOINTS & BOWED LINTELS. EXPOSURE 3 AND 4 DAMAGED JOINTS BOWED LINTELS AND SPALLING BRICKS. REMEDY: REPAIR AND/OR REPLACE #SR1102NS | DOB VIOLATION - ACTIVE |
| Aug 10, 2026 | CONSTRUCTION EWO DUE TO IMMINENT HAZARDOUS CONDITIONS @ EXP3 WEST ELEV COURTYARD @ PARAPET AREA. CRACK LOOSE BRICK WITH WALL MOVEMENT. REMEDY: OWNER TO IMMEDIATELY RETAIN NYS REGISTERED LICENSED PROFESSIONAL TO DIRECT, CONDUCT & SUPERVISE WORKS IN CONNECTION W/REMOV/STABLIZ OF CONDITIONS RDP TO PROV DAILY FIELD #SR1106NS | DOB VIOLATION - ACTIVE |
| Aug 10, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED THE FOLLOWING DEFECTIVE CONDITIONS AT ALL EXPOSURES. CRACKS,SPALLED/ SPALLING MISSING BRICKS DAMAGED JOINTS AND DECORATIVE STONES. ROOF AREA CRACK AT BULKHEAD AND PARAPET. REMEDY: REPAIR AND/OR REPLACE #SR1101NS | DOB VIOLATION - ACTIVE |
| Apr 10, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. EXPOSURE 1 & 3 DAMAGED MORTAR JOINTS, ERODED MORTAR & PARAPET. EXP#3 N ELEV ERODED MORTAR JOINTS @ MULT LOCATIONS, LOOSE BRICKS & COPING AT PARAPET; SPALLING & DAMAGED COPING ALSO @ PARAPET WALL. REMEDY: REPAIR AND/OR REPLACE ALL DAMAGE FACADE AND A #SR1101RF | DOB VIOLATION - ACTIVE |
| Apr 10, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. EXP1 DISINTEGRATING COPING STONE @ BULKHEAD.ERODING MORTAR JOINTS,DISLODGE MORTAR JOINTS @ PARAPET.EXP1 LOOSE TILE @ PARAPET WALL,BROKEN WINDOW PANE 6FL; ERODED MORTAR JOINTS,DISLODGE COPING & MORTAR JOINTS @ PARAPET.EXP4:REMEDY/ REQUIREMENTS: REPAI #SR1103RF | DOB VIOLATION - ACTIVE |
| Apr 10, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN CODE COMOPLIANT MANNER. ON EXPOSURE #1 AT TIME OF INSPECTION: LOOSE BRICKS, MISSING BRICKS, ERODING MORTAR JOINTS AT PROPERTY, MISSING BRICKS AT WINDOW SILLS AT 5TH FLOOR REMEDY: REPAIR AND/OR REPLACE DAMAGED BRICKS AND MORTAR JOINTS #SR1104RF | DOB VIOLATION - ACTIVE |
| Apr 10, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON EXPS # 1,2,3&4:ERODED DAMAGED BRICKS & MORTAR JOINTS @ PARAPET. EXPOSURE #4 NORTH ELEV:BROKEN WINDOW PANE @ STAIR WELL BETWEEN 3&4 FLS; LOOSE BRICKS;DAMAGED, DETERIORATED COPING STONE ON PARAPET. REMEDY: REPAIR AND/OR REPLACE #SR1102RF | DOB VIOLATION - ACTIVE |
| Oct 17, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE: OBSERVED DAMAGED/MISSING MORTAR JOINTS AND CRACKS IN MASONRY. AT SEVERAL LOCATIONS ON 1,2,3 OBSERVED SPALLING STONE LOOSE BRICK UNSECURED BRICK REMEDY: REPAIR AND/OR REPLACE #SR21103DO | DOB VIOLATION - ACTIVE |
| Oct 17, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT ALL EXPOSURE MULTIPLE DEFECTS. SPALLING MORTAR, MISSING MORTAR JOINTS, STEP CRACK, VERTICLE CRACKS, DAMAGED LINTELS, SPALLING STONE. LEANING PARAPET @ ROOF MULTIPLE CRACKS & BULKHEAD DAMAGED/MISSING ROOF TILE. LOOSE UNSECURE BRICK & PARAPET. #SR21101DO | DOB VIOLATION - ACTIVE |
| Oct 17, 2024 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO HAZARDOUS MATERIAL OBSERVED AT EXPOSURE#4 MULTIPLE VERTICAL CRACKS & STEP CRACKS. ALSO SPALLING DAMAGED MOTAR JOINTS LOOSE SPALLING STONE,LOOSE UNSECURED BRICK AND ROOF TILE REMEDY: IMMEDIATELY REMOVE LOOSE HAZARDOUS MATERIAL NOTED. IMMEDIATELY PROVIDE SHED/SAFETY MEASURE #SR211DO02 | DOB VIOLATION - ACTIVE |
| Oct 16, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED AT EXPOSURE 1, 3 & 4 MULTIPLE AREAS OF DIFFERENT DEFECTS SUCH AS SPALLING MORTAR JOINT, STEP CRACKS BRICKWORK, SPALLING/DAMAGED LINTELS, MISSING DAMAGED =/LOOSE STONES. PARAPET @ ROOF LEANING TOWARDS PUBILC, LOOSE BRICKS. MISSING ROOF TI #SR21103DO | DOB VIOLATION - ACTIVE |
| Oct 16, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE: AT TIME OF INSPECTION AT MULTIPLE LEVEL OF EACH FACADE HAD MULTIPLE CRACKS IN FACADE DAMAGE LINTELS SPALLING MORTAR JOINTS DISPLACED BRICKS DAMAGED PARAPET WALLS DAMAGED CRACK ROOF TILE SPALLING STONE LOOSE BRICKS CRACKED WINDOW SILLS. REM #SR21101DO | DOB VIOLATION - ACTIVE |
| Oct 16, 2024 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO HAZARDOUS MATERIALS OBSERVED @ EXP#2 SOUTH ELEV. AT PARAPET LEVEL ON THE CORNER OF THE EXPOSURE OBSERVED STEP CRACKS IN BRICK WORK. DAMAGED/SPALLING MORTAR JOINTS, SPALLING STONE W/LOOSE DEBRIS @EXP1 MAINTAINANCE ENTR/GARBAGE AREA.REMEDY:IMMEDIATELY REMOVE LOOSE HAZARDOUS #SR21102DO | DOB VIOLATION - ACTIVE |
| Oct 16, 2024 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO HAZARDOUS CONDITIONS @ EXPOSURE #3 DETERIORATING MASONRY ON ENTIRE FACADE, INCLUDING STEP CRACKS VERTICAL CRACKS BOWING LINTELS.MASONRY PUSH OFF SHELK ANGLES DAMAGE/SPALLING MORTAR JOINTS NEED SHED PROTECT MEAS EXP #1.REMEDY: IMMEDIATELY PROVID SAFE MEAS@EXP3 DEFECT COND #SR21104DO | DOB VIOLATION - ACTIVE |
| Jun 20, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED DAMAGED/MISSING MORTAR JOINTS AND CRACKS AT MASONRY AT SEVERAL LOCATIONS ON EXPOSURES #(1,2,& 3) (SOUTH; WEST & NORTH ELEVATION) REMEDY: FIX AND/OR REPLACE #SR21101YK | DOB VIOLATION - ACTIVE |
| Jun 7, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE DETERIORA TING MASONRY ON ENTIRE FACADE INCLUDING STEP CRACKS,VERTICAL CRACKS,BO WING LINTELS,MASONRY PUSHING OFF SHELF ANGLES,DAMAGED MORTAR JOINTS AN D SPALLED BRICKS CEMENTING MATERIAL.REMEDY: FIX AND/OR REPLACE #SR21101YK | DOB VIOLATION - ACTIVE |
| Jun 7, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AT THE TIME OF INSPECTION,OBSERVED AT ALL EXPOSURES CRACKED BRICK,LOOSE,DAMAGED MORTA R JOINTS,SPALLING COPING STONE AT ROOF LEVEL STEP CRACKS.THESE CONDITI ONS ARE AT VARIOUS DIFFERENT LEVELS OF THE FACADE.PARAPET HAS LOOSE DA MAGED MORTAR JOI #SR21104DO | DOB VIOLATION - ACTIVE |
| Jun 7, 2024 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO HAZARDOUS MATERIAL.OBSERVED AT EXP1 CRACKS IN THE FACADE AROUND 6TH FL.AT PARAPET LEVEL OBSERVED SPALLING,LOOSE MORTAR JOINTS,LOOSE BRICKS AND CRACKS IN THE BRICKS WHERE THERE IS NO SHED IN PLACE.REMEDY:IMMEDIATELY REMOVE LOOSE HAZARDOUS MATERIAL NOTED PROVIDE SWS SAFETY #SR21105DO | DOB VIOLATION - ACTIVE |
| Jun 7, 2024 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO THE HAZARDOUS CONDITION.OBSERVED DETERIORA TING MASONRY ON ENTIRE FACADE INCLUDING STEP CRACKS,VERTICAL CRACKS,BO WING LINTELS,MASONRY PUSHING OFF SHELF ANGLES,DAMAGED MORTAR JOINTS,SP ALLED BRICK AND CEMENT MATERIAL,INADEQUATE A/C SUPPORT.REMEDY:PROVIDE SAFETY MEASURES A #SR21102YK | DOB VIOLATION - ACTIVE |
| Jun 7, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE AT TIME O F INSPECTION,OBSERVED THROUGHOUT THE FACADE,CRACKS IN BRICK SPALLING M ORTAR JOINTS LOOSE BRICKS THAT WERE REMOVED AT TIME OF INSPECTION.STEP CRACKS,DAMAGED WINDOW SILL,CRACKED ROOF AT EXP1,3,4.REMEDY:REPAIR OR R EPLACE #SR21102DO | DOB VIOLATION - ACTIVE |
| Jun 7, 2024 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO HAZARDOUS MATERIAL OBSERVED AT EXP1,3 MULT IPLE HAZARDS THROUGHOUT THE FACADE INCLUDES STEP CRACK,BULDING NOT SEC URE,LOOSE MORTAR JOINTS,CRACKED BRICK OBSERVED ON FIRE ESCAPE.DAMAGED WINDOW SILLS,LINTELS BOWING,CRACKED.LOOSE BRICK WAS REMOVED FROM ROOF DURING INSPECTION. #SR21103DO | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #01366 | DOB VIOLATION - ACTIVE |
| Aug 18, 2015 | LANDMARK #16-0186 | DOB VIOLATION - ACTIVE |
| Aug 18, 2015 | LANDMARK #16-0185 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #11427 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #11426 | DOB VIOLATION - ACTIVE |
| Mar 26, 2002 | LOCAL LAW 62/91 - BOILERS #12482 | DOB VIOLATION - ACTIVE |
| Mar 26, 2002 | LOCAL LAW 62/91 - BOILERS #12483 | DOB VIOLATION - ACTIVE |
| Feb 27, 2001 | LOCAL LAW 62/91 - BOILERS #11459 | DOB VIOLATION - ACTIVE |
| Feb 27, 2001 | LOCAL LAW 62/91 - BOILERS #11458 | DOB VIOLATION - ACTIVE |
| Apr 23, 1988 | CONSTRUCTION #023S | DOB VIOLATION - ACTIVE |
| Mar 23, 1988 | CONSTRUCTION #023S | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Mar 26, 2002 | Boiler LL6291 | Active |
| Mar 26, 2002 | Boiler LL6291 | Active |
| Feb 27, 2001 | Boiler LL6291 | Active |
| Feb 27, 2001 | Boiler LL6291 | Active |
| Jun 9, 1994 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 13, 2010 | B | Apt T22 · SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CEILING. IN THE FOYER LOCATED AT APT T22, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTHEAST | — |
| Nov 13, 2010 | B | Apt T22 · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT T22, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTHEAST | — |
| Nov 13, 2010 | B | Apt T22 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR. IN THE FOYER LOCATED AT APT T22, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTHEAST | — |
| Nov 13, 2010 | B | Apt T22 · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR ALL CEILINGS, AND WALLS. IN THE ENTIRE APARTMENT LOCATED AT APT T22, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTHEAST | — |
| Nov 13, 2010 | C | Apt T22 · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING. IN THE FOYER LOCATED AT APT T22, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTHEAST | — |
| Nov 13, 2010 | B | Apt T22 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING. IN THE ENTIRE APARTMENT LOCATED AT APT T22, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTHEAST | — |
| Oct 30, 2026 | B | Apt L53 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT L53, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SE | Dec 4, 2026 |
| Oct 30, 2026 | B | Apt L53 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT L53, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECT | Dec 4, 2026 |
| Oct 30, 2026 | B | Apt L53 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT L53, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''L'' | Dec 4, 2026 |
| Oct 30, 2026 | C | Apt L53 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT L53, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''L'' | Nov 25, 2026 |
| Oct 29, 2026 | C | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. | Nov 24, 2026 |
| Oct 29, 2026 | C | Apt Y31 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT Y31, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''Y'' | Nov 12, 2026 |
| Oct 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''''L'''' | Nov 12, 2026 |
| Oct 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE CLOSURE ARM AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''T'' | Nov 12, 2026 |
| Oct 29, 2026 | B | Apt N51 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT N51, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''N'' | Dec 3, 2026 |
| Oct 29, 2026 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''K'' | Nov 4, 2026 |
| Oct 29, 2026 | B | § 27-2005 ADM CODE PROVIDE GLASS IN LIEU OF PLEXI GLASS INSTALLLED ON BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''V'' | Dec 3, 2026 |
| Oct 29, 2026 | B | Apt V3 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CABINET AT WESL WALL IN THE KITCHEN LOCATED AT APT V3, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''V'' | Dec 3, 2026 |
| Oct 29, 2026 | C | Apt N51 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CRACKED MIRROR AT VANITY IN THE BATHROOM LOCATED AT APT N51, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''N'' | Nov 4, 2026 |
| Oct 29, 2026 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''''L'''' | Nov 4, 2026 |
| Oct 29, 2026 | C | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE 7TH MARBLE TREAD FROM BOTTOM UP AT PUBLIC HALL STAIRS, 3rd STORY, SECTION ''N'' | Nov 4, 2026 |
| Oct 29, 2026 | B | Apt M21 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT M21, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''M'' | Dec 3, 2026 |
| Oct 29, 2026 | C | Apt Y31 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT Y31, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''Y'' | Nov 24, 2026 |
| Oct 29, 2026 | B | Apt N51 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ELECTRICAL WIRES AT SOUTH WALL. IN THE FOYER LOCATED AT APT N51, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''N'' | Dec 3, 2026 |
| Oct 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''V'' | Nov 12, 2026 |
| Oct 29, 2026 | C | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ELECTRICAL WIRES AT WEST WALL AT PUBLIC HALL, 1st STORY, SECTION ''K'' | Nov 4, 2026 |
| Oct 29, 2026 | B | Apt M21 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SADDLE AT ENTRANCE IN THE 1st ROOM FROM EAST LOCATED AT APT M21, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''M'' | Dec 3, 2026 |
| Oct 29, 2026 | B | Apt M21 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CABINET DOOR AT WEST WALL IN THE BATHROOM LOCATED AT APT M21, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''M'' | Dec 3, 2026 |
| Oct 29, 2026 | C | Apt M21 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT M21, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''M'' | Nov 4, 2026 |
| Oct 29, 2026 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXI GLASS INSTALLED ON BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''V'' | Nov 4, 2026 |
| Oct 29, 2026 | B | Apt N51 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT N51, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''N'' | Dec 3, 2026 |
| Oct 29, 2026 | C | Apt Y31 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SHATTERED GLASS PANE AT LOWER SASH AT SOUTH WALL WINDOW IN THE 3rd ROOM FROM EAST LOCATED AT APT Y31, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''Y'' | Nov 4, 2026 |
| Oct 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''K'' | Nov 12, 2026 |
| Oct 29, 2026 | B | § 27-2005 ADM CODE PROVIDE GLASS IN LIEU OF PLEXI GLASS INSTALLED AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''N'' | Dec 3, 2026 |
| Oct 29, 2026 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''V'' | Nov 4, 2026 |
| Oct 29, 2026 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SHATTERED WIRED GLASS PANE AT LOWER SASH AT NORTH WALL WINDOW AT PUBLIC HALL STAIRS, 4th STORY, SECTION ''K'' | Nov 4, 2026 |
| Oct 29, 2026 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXI GLASS INSTALLED AT BUILDING EXTRANCE DOOR. , 1st STORY, SECTION ''N'' | Nov 4, 2026 |
| Oct 29, 2026 | C | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. | Nov 24, 2026 |
| Oct 28, 2026 | B | Apt X13 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT BSMT-APT X13, 1st BSMT-APT FROM SOUTH AT WEST | Dec 2, 2026 |
| Oct 28, 2026 | C | Apt M2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT M2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''M'' | Nov 23, 2026 |
| Oct 28, 2026 | B | Apt Y53 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT Y53, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECT | Dec 2, 2026 |
| Oct 28, 2026 | B | Apt X13 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT BSMT-APT X13, 1st BSMT-APT FROM SOUTH AT WEST | Dec 2, 2026 |
| Oct 28, 2026 | B | Apt Z32 · § 27-2005 HMC: REFIT LOWER SASH AT 2ND WINDOW FROM EAST AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT Z32, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''Z'' | Dec 2, 2026 |
| Oct 28, 2026 | B | Apt X13 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT X13, 1st APARTMENT FROM SOUTH AT WEST | Dec 2, 2026 |
| Oct 28, 2026 | B | Apt Y53 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT Y53, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SE | Dec 2, 2026 |
| Oct 28, 2026 | B | Apt M2 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT M2, 1st STORY, 1st APARTMENT FROM WEST AT N | Dec 2, 2026 |
| Oct 28, 2026 | B | Apt X13 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT X13, 1st APARTMENT FROM SOUTH AT WEST | Dec 2, 2026 |
| Oct 28, 2026 | B | Apt Y53 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT Y53, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''Y'' | Dec 2, 2026 |
| Oct 28, 2026 | B | Apt M2 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT M2, 1st STORY, 1st APARTMENT FROM WEST AT NOR | Dec 2, 2026 |
| Oct 28, 2026 | B | Apt Y53 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT Y53, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''Y'' | Dec 2, 2026 |
| Oct 26, 2026 | B | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. | Nov 30, 2026 |
| Oct 23, 2026 | B | Apt W31 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT CEILING IN THE BATHROOM LOCATED AT APT W31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''2857'' ORIGINAL VIOLATION 19028822 ISSUED 24-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINIST | Nov 27, 2026 |
| Oct 19, 2026 | B | Apt X6 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, NORTH AND EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT X6, 1st APARTMENT FROM WEST AT NORTH | Nov 23, 2026 |
| Oct 19, 2026 | A | Apt X6 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ.FT AT CEILING AND NORTH WALL IN CLOSET AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT BSMT-APT X6, 1st BSMT-APT FROM WEST AT NORTH | Jan 22, 2027 |
| Oct 19, 2026 | B | Apt X6 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR BROKEN IN THE BATHROOM LOCATED AT BSMT-APT X6, 1st BSMT-APT FROM WEST AT NORTH | Nov 23, 2026 |
| Oct 19, 2026 | B | Apt X6 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR TILES LIFTING IN THE 1st ROOM FROM EAST LOCATED AT BSMT-APT X6, 1st BSMT-APT FROM WEST AT NORTH | Nov 23, 2026 |
| Oct 19, 2026 | B | Apt X6 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING ,NORTH AND EAST WALL ( BASEMENT APARTMENT ) IN THE 1st ROOM FROM EAST LOCATED AT APT X6, 1st APARTMENT FROM WEST AT NORTH | Nov 23, 2026 |
| Oct 13, 2026 | B | Apt P22 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, NORTH AND WEST WALLS IN THE FOYER LOCATED AT APT P22, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''P'' | Nov 17, 2026 |
| Oct 13, 2026 | B | Apt P1 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFEVTIVE IN THE ENTIRE APARTMENT LOCATED AT APT P1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SEC | Nov 17, 2026 |
| Oct 13, 2026 | B | Apt P1 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT P1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , S | Nov 17, 2026 |
Showing 60 of 366. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 30, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT L53, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SE | Open |
| Oct 30, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT L53, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECT | Open |
| Oct 30, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT L53, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''L'' | Open |
| Oct 30, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT L53, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''L'' | Open |
| Oct 29, 2026 | HPD C | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. | Open |
| Oct 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT Y31, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''Y'' | Open |
| Oct 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''''L'''' | Open |
| Oct 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE CLOSURE ARM AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''T'' | Open |
| Oct 29, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT N51, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''N'' | Open |
| Oct 29, 2026 | HPD C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''K'' | Open |
| Oct 29, 2026 | HPD B | § 27-2005 ADM CODE PROVIDE GLASS IN LIEU OF PLEXI GLASS INSTALLLED ON BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''V'' | Open |
| Oct 29, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CABINET AT WESL WALL IN THE KITCHEN LOCATED AT APT V3, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''V'' | Open |
| Oct 29, 2026 | HPD C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CRACKED MIRROR AT VANITY IN THE BATHROOM LOCATED AT APT N51, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''N'' | Open |
| Oct 29, 2026 | HPD C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''''L'''' | Open |
| Oct 29, 2026 | HPD C | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE 7TH MARBLE TREAD FROM BOTTOM UP AT PUBLIC HALL STAIRS, 3rd STORY, SECTION ''N'' | Open |
| Oct 29, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT M21, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''M'' | Open |
| Oct 29, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT Y31, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''Y'' | Open |
| Oct 29, 2026 | HPD B | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ELECTRICAL WIRES AT SOUTH WALL. IN THE FOYER LOCATED AT APT N51, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''N'' | Open |
| Oct 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''V'' | Open |
| Oct 29, 2026 | HPD C | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ELECTRICAL WIRES AT WEST WALL AT PUBLIC HALL, 1st STORY, SECTION ''K'' | Open |
| Oct 29, 2026 | HPD B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SADDLE AT ENTRANCE IN THE 1st ROOM FROM EAST LOCATED AT APT M21, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''M'' | Open |
| Oct 29, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CABINET DOOR AT WEST WALL IN THE BATHROOM LOCATED AT APT M21, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''M'' | Open |
| Oct 29, 2026 | HPD C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT M21, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''M'' | Open |
| Oct 29, 2026 | HPD C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXI GLASS INSTALLED ON BUILDING ENTRANCE DOOR , 1st STORY, SECTION ''V'' | Open |
| Oct 29, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT N51, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''N'' | Open |