Bronx · Block 5519 · Lot 91 · 10465

280 Longstreet Avenue

7 floors · 63 apartments · 63,749 sq ft · built 1965 · class D1 · owner of record: 280 Longstreet, Llc

124open violations
$62,402ECB/OATH penalties owed
21HPD class C (immediately hazardous)
56dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 56 days
Annual
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-07-16 (Accepted). Agency page

Dec 31, 2026
in 56 days
3 of 3 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 72 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $3,985,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 108 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 63,749 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 177 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 177 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 300 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 787 days
Next cycle year 2028
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5519). Agency page

Dec 31, 2029
in 1152 days
Next due 2029

Open violations

ECB / OATH (34) · $62,402 owed
IssuedViolationHearingBalance
Sep 16, 2026Construction CLASS - 1
NOTED AT THE TIME OF INSPECTION, A LARGE ACCUMULATION OF DEBRIS AND CONSTRUCTION MATERIALS WAS OBSERVED OBSTRUCTING THE SCAFFOLD ENTRYWAY AT EXPOSURE #1, FRONT-LEFT CORNER OF THE PROPERTY. THE OBSTRUCTED ACCESS
#39204264L
Nov 20, 2026
PENDING
$2,500
Aug 21, 2026Elevators CLASS - 1
FAILURE TO MAINTAIN ELEVATOR IN CODE COMPLAINT MANNER AS PER BC 3001.2 & 27-987 CLASS 1 VIOLATION: EMERGENCY COMMUNICATION DEVICE INOPERATIVE, THIS A DEVICE IMPERATIVE FOR TENANTS SAFETY, REMEDY: FIX AND EMAIL
#39201330R
Jan 8, 2027
PENDING
$1,250
Aug 18, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION OF A 6-STORY BUILDING UNDER FACADES REPAIRS, I OBSERVED WORKERS USING PIPE SCAFFOLDING, UPON REQUESTING THE COMPETENT PERSON NON WAS ONSITE AS REQUIRE BY CODE 3314.4.5.1 AND UPON REQUE
#39558106Y
Oct 30, 2026
IN VIOLATION
$2,500
Aug 18, 2026Unknown CLASS - 2
AT TIME OF INSPECTION OF A 6-STORY BUILDING, I NOTICED SIDEWALK SHED ERECTED NOT MAINTAIN AS PER CODE 3307.6.5.5 & 3303.4.4.1 THROUGHOUT SIDEWALK SHED BRICKS GARBAGE BAG CONSTRUCTION DEBRIS HAS LEFT ON TOP OF S
#39558105M
Oct 30, 2026
IN VIOLATION
$2,500
Aug 18, 2026Unknown CLASS - 2
AT TIME OF INSPECTION OF THE 6-STORY ALTERATION JOB, SUPPORTED SCAFFOLDING WAS OBSERVED ERECTED WITH LOOSE VERTICAL NETTING THAT WAS NOT PROPERLY MAINTAINED AS PER BC 3314.8.2 THIS CONDITION PRESENTS AN IMMEDIA
#39558103Z
Mar 29, 2027
PENDING
$2,500
Aug 18, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION OF A 6-STORY BUILDING UNDER FACADES REPAIRS, I OBSERVED PLASTIC JERSEY BARRIERS AND PORTA-POTTY OBSTRUCTION THE ROADWAY WHERE CAR PARK. UPON REQUEST WORKERS, RESEARCH DOT WEBSITE AND
#39558104K
Oct 30, 2026
IN VIOLATION
$2,500
Aug 6, 2026Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED THE FOLLOWING, OBJECT STORED AT FIRE ESCAPE LANDING ON EXPOSURE 2 7TH FLOOR. REMEDY: REMOVE EGRESS OBSTRUCTION.
#35730739K
Oct 16, 2026
IN VIOLATION
$1,250
Jul 16, 2026Elevators CLASS - 1
CEASE USE: DOOR RESTRICTOR INOPERATIVE. IN VIOLATION OF ASME A17.1-2013 2.14.5.7 AND 2.14.4.2. CONDITION EXPOSES THE HOISTWAY AND CONSTITUTES AN IMMEDIATE HAZARD. REPAIR AND E-MAIL THE ELEVATOR DIVISION AT EIR@
#39196463R
Oct 2, 2026
IN VIOLATION
$1,250
Apr 24, 2026Construction CLASS - 2
AT TIME OF INSPECTION, ACTIVE FACADE REPAIR AT 6-STORY BUILDING. FOREMAN ON SITE; APPROVED DOCUMENTS AND LOGS PROVIDED. INADEQUATE NETTING OBSERVED AT SIDEWALK SHED AT EXPOSURE 1 AND EQUIPMENT AREA. CONDITION R
#39553436Y
Jan 8, 2027
$2,400
Apr 20, 2026Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A, 8A, AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #914999. AGG1: PRIOR NOV 37026550K
#37036609P
Jul 31, 2026
IN VIOLATION
$3,125
Oct 22, 2025Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AS NOTED: AT THE TIMEOF INSPECTION I OBSERVED OBJECTS ON FIRE ESCAPE ON EXP. 2 AND 3 ON 5THAND 6TH FLOORS. REMEDY: REMOVE OBSTRUCTION.
#35718519R
Jan 2, 2026
IN VIOLATION
$1,250
Oct 22, 2025Construction CLASS - 2
PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. AS NOTED: AT TIME OF INSPECTION I OBSERVED MISSING AND LOOSE, PARAPET PANELS AND LEANING OUT PANELS. REMEDY: COMPLY TO CODE SPECIFICATIONS.
#35718518P
Apr 1, 2027
DEFAULT
$5,000
May 13, 2025Elevators CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. CLASS 2 ITEMS: 1) IN CAR COMMUNICATION INOPERATIVE, REPAIR. 2) PIT DIRTY, CLEAN. 3) COUNTERWEIGHT SPINOUT MISSING A SECOND CROSBY. 4) MOTOR ROOM DOOR MISSI
#39147829L
Oct 31, 2025
IN VIOLATION
$625
Apr 29, 2025Unknown CLASS - 2
AT TIME OF INSPECTION OF A 7-STORY RESIDENTIAL BUILDING, I OBSERVED NO SIGN OF CONSTRUCTION ACTIVITIES. DURING MY INSPECTION I NOTICED SUPPORTED SCAFFOLDS ERECTED EXP#1-3 NOT MAINTAIN AS PER BC3314.9.2 FOUNDATI
#39539625M
Aug 29, 2025
IN VIOLATION
$2,500
Apr 8, 2025Unknown CLASS - 2
(3314.1) TIME OF MY INSPECTION I OBSERVED A 7 STORY BUILDING WITH PIPE SCAFFOLD. I NOTICED THAT SAFETY DEBRI NETTING IS LOOSE AND UNSECURE. THIS CREATES A UNSAFE SITUATION WITH DEBRI NETTING COMING LOOSE AND FA
#39538851X
Jun 20, 2025
IN VIOLATION
$2,500
Mar 4, 2025Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION, CEASE USE VIOLATION ISSUED FOR THE FOLLOWING, ALTERED CAR DOOR RESTRICTOR, TO MAKE IT TO NOT WORK TO CODE. / (DLM) DOOR LOCK MONITORING SYSTEM. NOT WORKI
#39140365K
May 16, 2025
IN VIOLATION
$1,250
Jan 29, 2025Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39090776M ISSUED ON 07/22/2023, AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2). AN ACCEPTABLE CERT
#37033017H
Jul 25, 2025
IN VIOLATION
$1,250
Aug 26, 2024Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS#39052126N ISSUED ON 12/2/2021,AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1RCNY 102-01(D)(2).AN ACCEPTABLE CERTIFICA
#37029044L
Nov 3, 2025
IN VIOLATION
$1,250
Jul 30, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS FACADE AND APPURTENANCES:OBSERVED DAMAGED BALCONY SLABE ON ALL STORY OF EXPOSURE 1 SOUTH ELEVATOR AND EXPOSURE 3 NORTH ELEVATION.HAIRLINE CRACK AT EXPOSURE 2 WEST ELE
#35684002L
Aug 5, 2025
IN VIOLATION
$1,250
May 20, 2024Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: MULTIPLE HAZARDOUS CONDITIONS OBSERVED. (1)AT EXPOSURE #4(EAST) BULGING SIDING CONCEALING FACADE AT 6TH STORY. (2)BULGING BRICKS/MASONRY AT
#35685235R
Jan 24, 2025
IN VIOLATION
$2,500
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A,8A,AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#914999.REM:FILE ACCEPTABLE REPORT.
#37026550K
May 3, 2024
DEFAULT
$6,250
Jul 22, 2023Elevators CLASS - 2
RESPONDING TO A 311ELEVATOR COMPLAINT, UPON INSPECTION OF DEVICE, CLASS 2 RECURRING, IN CAR PHONE NOT WORKING,VIOLATION ISSUED, CLASS 2, 1/ 4 AMP FUSE JUMP ON CONTROLLER, 3/ MOTOR ROOM DOOR SIGNAGE MISSING, 4/
#39090776M
Sep 29, 2023
STIPULATION/IN-VIO
$1,562
Sep 10, 2022Elevators CLASS - 1
CEASE USE ITEM, 1) CAR DOOR RESTRICTOR ALTERED TO MAKE IT NOT TO WORK, REMEDY REPAIR THEN CONTACT NYCDOB FOR RESTORE TO SERVICE RE-INSPECTION,........ CLASS 1 RECURRING VIOLATION ISSUED , DLM IMPROPERLY INSTALL
#39069750H
Nov 4, 2022
IN VIOLATION
$3,125
May 23, 2022Elevators CLASS - 1
CLASS 1 VIOLATION ISSUED , / DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER. INSTALL, FIREMAN SERVICE SO DLM , IS IN COMPLIANCE WITH SECTION 3.10.12 OF APPENDIX K3. CLASS 2 VI
#39062717Y
Sep 2, 2022
IN VIOLATION
$3,125
May 11, 2022Elevators CLASS - 1
97X17: 97-X-17 CLASS 1 RESTORE TO SERVICE. REPAIR ELEVATOR & RESTORE TO SERVICE IMMEDIATELY CALL NYC DEPT OF BUILDINGS ELEVATOR DIVISION & EMAIL ELEVATORIR@BUILDINGS.NYC.GOV FOR REINSPECTION
#38274412L
Aug 5, 2022
IN VIOLATION
$1,250
May 3, 2022Elevators CLASS - 1
OUT OF SERVICE
#39061985X
Aug 19, 2022
IN VIOLATION
$1,250
Mar 8, 2022Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BLDG FACADE&APPURTENANCES ATOI OBSERVED@EXP1&3 DAMAGED BALCONY SLABS&BEAMS@MULTIPLE LOCATION ALSO OBSERVED DEGRADED MORTAR JOINT&CRACK VARIOUS LOCATION.@ROOF OBSERVED CRACK ON BULKH
#35647357H
Jun 3, 2022
IN VIOLATION
$0
Feb 22, 2022Elevators CLASS - 1
CLASS 1 VIOLATION ISSUED DLM IMPROPERLY INSTALLED ON THIS DEVICE, NO FIREMAN SERVICE PRESENT IN CONTROLLER. INTALL FIREMAN SERVICE SO DLM IS IN COMPLIANCE WITH SECTION 3.10.12 OF APPENDIX K3. CLASS 2 VIOLATION
#39056728Z
Oct 24, 2022
IN VIOLATION
$3,125
Jan 14, 2022Elevators CLASS - 1
CLASS 1 VIOLATION ITEM,/ DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SECTION 3,10,12 OF APPENDIX K3. CLASS 2 VIOLATION ISSUED, ITEM / IN CAR FAN NOT WORKING. REMEDY REPAIR,
#39054349J
Oct 24, 2022
IN VIOLATION
$1,250
Dec 2, 2021Boilers CLASS - 2
BOILER SHELL CORRODED/LEAKING-STAYBOLTS MISSING-TUBE LEAK-WATER COLUMN PIPE CORRODED/LEAK-CONTROL COVERS MISSING-NO GUARDS WATER LEVEL GLASS-PILOT REGULATOR NOT VENTED-NO DRIP ON BACKFLOW VALVE-DISCHARGE FOR CO
#39052126N
Jan 21, 2022
STIPULATION/IN-VIO
$315
Oct 7, 2021Elevators CLASS - 1
CLASS 1 NO FIREMAN SERVICE PRESENT IN CONTROLLER. INSTALL FIREMAN SERVICE SO DLM IS IN COMPLIANCE WITH SECTION 3.10.12 OF APPENDIX K3, CLASS 2 VIOLATION ITEMS,/ CAR RUBBING HOIST WAY BETWEEN LOBBY TO FIRST FLOO
#39048973M
Jan 21, 2022
ADMIT/IN-VIO
$0
Mar 30, 2014Plumbing CLASS - 2
GAS BEING SUPPILED TO BLDG W/O INSP & CERT BY DOB.GAS BEING SUPPLIED TO DRYERS W/O AUTHORIZER FROM THIS DEPT.REM:OBTAIN A PERMIT & HAVE NECESSARY TEST & INSP PERFORMED.
#34869422M
Sep 12, 2014
IN VIOLATION
$0
Mar 30, 2014Plumbing CLASS - 2
FAILURE TO MAINTIAN BLDG IN CODE COMPLIANT MANNER LACK OF A SYSTEM OF AUTOMATTIC SPRINKLERS WHERE REQUIRED PER BC 903.2 27-954.OBSERVED @ LOCATION(4) GAS DRYERS INSTALLED W/O SP COVERAGE 2-OR MORE DRYERS REQUIR
#34869420Z
Sep 12, 2014
IN VIOLATION
$0
Mar 30, 2014Plumbing CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER REINSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC102 3;27-902.OBSERVED IN LAUNDRY ROOM DRYERS INSTALLED W/ FLEX STOVE CONNECTIONS DRYERS ARE REQ
#34869421K
Sep 12, 2014
IN VIOLATION
$0
DOB (18)
IssuedViolationStatus
Jun 17, 2026CONSTRUCTION
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER: DOB VIOLATION #030822CLLF AO1MR REQUIRED THE IMMEDIATE 100% HANDS ON INSPECTION OF ALL FACADES BY A NYS PE/RA AND SUBMIT A REPORT TO FACADES VIA EMAIL BY 3/8/2022 AS OF 6/17/26. NO HANDS ON INSPECTION REPORT SUBMITTED TO FACADE UNIT REMEDY: COMPLY WITH DO
#LL21008CM
DOB VIOLATION - ACTIVE
Oct 22, 2025CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AS NOTED AT THE TIME OF INSPECTION,I OBSERVED ON EXP1,2,3,4 DEFECTIVE FACADE CONDITION SUCH AS DAMAGED BALCONY SLABS,CRACKS IN BALCONY CONCRETE BEAMS,SAGGING CORRODED METAL LINTEL,BROCKEN WINDOW PANE ON 6TH FL.INADEQUATE AC SUPP ORTS ON 6TH & 7TH
#SR1001RF
DOB VIOLATION - ACTIVE
Dec 11, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00468
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01323
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01324
DOB VIOLATION - ACTIVE
Jun 1, 2022FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00773
DOB VIOLATION - ACTIVE
May 11, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00261
DOB VIOLATION - ACTIVE
Mar 8, 2022CONSTRUCTION
EMERGENCY WORK ORDER-DUE TO CRACKED AND SPALLED CONCRETE BALCONIES SLABS AT SOUTH AND NORTH ELEVATION(EXP 1,3) ALSO THE COLIMNS SUPPORTING BALCONY SLABS REQUIRED ADDITIONAL SHORING DUE TO DAMAGE BEARING POINTS. REMEDY: IMMED PROVIDE ADEQUATE SHORING SYSTEM FOR THE DEFECTED BALCONIES UNDER NYS LIC EN
#LLFA03MR
DOB VIOLATION - ACTIVE
Mar 8, 2022CONSTRUCTION
FTM FACADE AND APPURTENANCES ON 03/08/22 OBSERVED CRACK AND SPALLED BALCONY CONCRETE SLAB AND BEAMS AT EXP 1 AND 3 MULTIPLE LOCATION REMEDY: OWNER TO IMMED RETAIN SERVICES OF NYSPE/RA W/MASONRY FACADE RESTORATION & REPAIR EXPERIENCE TO INSP AND EVAL 100% OF(HANDS ON/ SOUND)AT BALCONIES EXP 1 AND 3
#LLFA01MR
DOB VIOLATION - ACTIVE
Mar 8, 2022CONSTRUCTION
PARTIAL CACTE ORDER-OBSERVED BY FACADE INSPECTOR ON 03/08/2022 THERE ARE CRACKED AND SPALLED BALCONY CONCRETE SLABS AT EXP #1 AND #3 ALL OF THEM DUE TO THESE CONDITIONS EXP #1 AND #2 ALL BALCONIES ARE TO BE VACATED.PROVIDE PROTECTION TO RESTRICT TENANT ACCESS TO THE BALCONIES REMEDY: VACATE ALL BALC
#LLFA02MR
DOB VIOLATION - ACTIVE
Feb 2, 2022FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00275
DOB VIOLATION - ACTIVE
Nov 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00368
DOB VIOLATION - ACTIVE
Oct 20, 2021HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#909489
DOB VIOLATION - ACTIVE
Oct 20, 2021HAZARDOUS CONDITION (FACADE)
CYCLE 8A UNSAFE REPORT FILED
#809488
DOB VIOLATION - ACTIVE
Oct 10, 2021FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2020)
#00021
DOB VIOLATION - ACTIVE
Aug 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00533
DOB VIOLATION - ACTIVE
Jun 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00830
DOB VIOLATION - ACTIVE
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2002785
DOB VIOLATION - ACTIVE
DOB NOW Safety (17)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction
Active
Oct 21, 2026AEUHAZ FTC-AEU-HAZ
Active
Sep 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Dec 11, 2024AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Jun 1, 2022Benchmarking - LL84 FTF-EN-BENCH
Active
May 11, 2022AEUHAZ FTC-AEU-HAZ
Active
Feb 2, 2022Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Oct 20, 2021Facades FISPHAZ
CYCLE 8A UNSAFE REPORT FILED
Active
Oct 20, 2021Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Oct 10, 2021Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Aug 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
HPD (67) · C 21 · B 30 · A 16
IssuedClassViolationCorrect by
Oct 30, 2026CApt 5D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM WEST AT NORTHNov 25, 2026
Oct 6, 2026BApt 5D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT WINDOW FRAME AT EAST WALL IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18977563 ISSUED 03-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMNov 10, 2026
Sep 28, 2026CApt 5D · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOct 12, 2026
Sep 28, 2026CApt 5D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOct 24, 2026
Sep 28, 2026CApt 5D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCK AND ITS ASSEMBLIES AT APARTMENT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOct 4, 2026
Sep 28, 2026BApt 5D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE 1st ROOM FROM EAST LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTHNov 2, 2026
Sep 28, 2026BApt 5D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RUBBER GASKETS AT UPPER AND LOWER REFRIGERATOR DOORS IN THE KITCHEN LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTHNov 2, 2026
Sep 28, 2026BApt 5D · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORNov 2, 2026
Sep 28, 2026BApt 5D · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THATS IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTNov 2, 2026
Aug 7, 2026CApt 5D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM WEST AT NORTHSep 2, 2026
Dec 22, 2025BApt 3E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHJan 26, 2026
Dec 18, 2025BApt 5G · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GASKET SEAL AT LOWER REFRIDGERATOR DOOR IN THE KITCHEN LOCATED AT APT 5G, 5th STORY, 4th APARTMENT FROM WEST AT NORTHJan 22, 2026
Dec 12, 2025CApt 5G · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 4th APARTMENT FROM WEST AT NORTHDec 18, 2025
Nov 12, 2025C§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS FULLY EXTENDED AT SOUTH EXTERIOR WALL FRONT OF BUILDING AT FIRE ESCAPENov 18, 2025
Sep 2, 2025CApt 5G · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 2, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 4th APARSep 28, 2025
Sep 2, 2025B§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS DROP LADDER FULLY EXTENDED AT SOUTH EXTERIOR WALL FRONT OF BUILDING AT FIRE ESCAPEOct 7, 2025
May 14, 2025BApt 5G · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 5G, 5th STORY, 4th APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17618129 ISSUED 13-JAN-25 HAS BEEN UPGRADED TO CLASS B PER Jun 18, 2025
Apr 3, 2025A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION REMOVAL OF NORTH 2 HALLWAY DOOR TO GARBAGE AREA,BASEMENT STORYJul 7, 2025
Apr 2, 2025CApt 6C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT APT 6C, 6th STORY, APARTMENT AT NORTHApr 28, 2025
Apr 2, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND EAST WALL, AT PUBLIC HALL, 6th STORYJul 6, 2025
Mar 26, 2025BApt 5E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 5E, 52nd STORY, 2nd APARTMENT FROM WEST AT NORTHApr 30, 2025
Mar 10, 2025BApt 5E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 5E, 6th STORY, 2nd APARTMENT FROM WEST AT NORTHApr 14, 2025
Mar 10, 2025BApt 5E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CIELING IN THE 1st ROOM FROM EAST LOCATED AT APT 5E, 6th STORY, 2nd APARTMENT FROM WEST AT NORTHApr 14, 2025
Mar 6, 2025CApt 5G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 4th APARTMENT FROM WEST AT NORTHApr 1, 2025
Mar 6, 2025A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION REMOVAL OF NORTH 2 DOOR LEADING TO GARBAGE AREA AT PUBLIC HALL, 1st STORYJun 9, 2025
Jan 30, 2025CApt 5D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM WEST AT NORTHFeb 25, 2025
Jan 30, 2025CApt 5D · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM WEST AT NORTHFeb 13, 2025
Jan 30, 2025CApt 5D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM WEST AT NORTHFeb 25, 2025
Jan 14, 2025BApt 5G · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 5G, 5th STORY, 4th APARTMENT FROM NORTH AT EASTFeb 18, 2025
Jul 11, 2024A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT FIRST BALCONY AT SOUTH EXTERIOR WALL , 5th STORYOct 14, 2024
Jul 11, 2024A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING OF FIRST BALCONY FROM WEST AT SOUTH EXTERIOR WALL , 6th STORYOct 14, 2024
Jul 11, 2024B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT AT 6TH STORY AT CEILING OF BALCONY AT FIRST STACK BALCONY FROM WEST AT SOUTH EXTERIOR WALL , 6th STORYAug 15, 2024
Jul 11, 2024B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT AT 4TH STORY BALCONY CEILING AT FIRST STACK FROM WEST AT SOUTH EXTERIOR WALL , 4th STORYAug 15, 2024
Jul 11, 2024A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT FIRST BALCONY FROM WEST AT 4TH STORY AT SOUTH EXTERIOR WALL , 4th STORYOct 14, 2024
Jul 11, 2024B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT AT 5TH STORY BALCONY CEILING AT FIRST STACK FROM WEST AT SOUTH EXTERIOR WALL , 5th STORYAug 15, 2024
Jul 8, 2024AApt 6B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE TERRACE LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM EAST AT SOUTHOct 11, 2024
Jul 8, 2024CApt 6B · § 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT CONSISTING OF CRACKED CONCRETE FLASHING AROUND SUPPORT BEAM AT CEILING IN THE TERRACE LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM EAST AT SOUTHJul 14, 2024
May 1, 2024BApt LC · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL APPROX 4 SQ FR AT EAST WALL APPROX 4 SQ FT AT NORTH WALL APPROX 4 SQ FT IN THE BATHROOM LOCATED AT CELLAR APT LC, 1st CELLAR APT FROM SOUTH AT WESTJun 5, 2024
May 1, 2024BApt LC · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE COUNTER TOP AT SINK IN THE KITCHEN LOCATED AT CELLAR APT LC, 1st CELLAR APT FROM SOUTH AT WESTJun 5, 2024
May 1, 2024BApt LC · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD BASE CABINT AT SINK IN THE KITCHEN LOCATED AT CELLAR APT LC, 1st CELLAR APT FROM SOUTH AT WESTJun 5, 2024
May 1, 2024BApt 6B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 7 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16551576 ISSUED 28-DEC-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-20Jun 5, 2024
May 1, 2024CApt LC · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WAREPED WOOD FLOOR TRIP (HARZZERD) IN THE 1st ROOM FROM EAST LOCATED AT CELLAR APT LC, 1st CELLAR APT FROM SOUTH AT WESTMay 7, 2024
Feb 9, 2024BApt LC · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL THE WALLS IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT BSMT-APT LC, 1st BSMT-APT FROM WEST AT NORTHMar 15, 2024
Feb 9, 2024BApt LC · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... ON NORTH WALL APPROX. 10 SQ FT. IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT BSMT-APT LC, 1st BSMT-APT FROM WEST AT NORTHMar 15, 2024
Feb 6, 2024AApt LC · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR TILES IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT BSMT-APT LC, 1st BSMT-APT FROM WEST AT NORTHMay 11, 2024
Dec 5, 2023BApt LC · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE OUTLET AT EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT LC, 1st APARTMENT FROM SOUTH AT WESTJan 9, 2024
Nov 20, 2023A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL AT PUBLIC HALL, 5th STORYFeb 23, 2024
Nov 20, 2023CApt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM WEST AT NORTHDec 16, 2023
Sep 13, 2023CApt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM WEST AT NORTHOct 9, 2023
Aug 15, 2023BApt 2G · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... INSIDE CABINETS AT EAST WALL IN THE KITCHEN LOCATED AT APT 2G, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTSep 19, 2023
Jul 31, 2023BApt 1C · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT RISER AT CEILING IN THE BATHROOM LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTSep 4, 2023
May 25, 2023AApt 1C · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT HEAT RISER IN THE BATHROOM LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTAug 28, 2023
Mar 28, 2022CApt LC · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT CELLAR APT LC, 1st CELLAR APT FROM SOUTH AT WESTApr 23, 2022
Mar 28, 2022BApt LC · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR INSIDE BASE CABINET UNDER SINK IN THE KITCHEN LOCATED AT CELLAR APT LC, 1st CELLAR APT FROM SOUTH AT WESTMay 2, 2022
Mar 28, 2022BApt LC · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL CEILINGS AND WALLS IN THE ENTIRE APARTMENT LOCATED AT CELLAR APT LC, 1st CELLAR APT FROM SOUTH AT WESTMay 2, 2022
Mar 28, 2022BApt LC · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ALL WOOD FINISH FLOORING IN THE ENTIRE APARTMENT LOCATED AT CELLAR APT LC, 1st CELLAR APT FROM SOUTH AT WESTMay 2, 2022
Nov 30, 2021AApt LC · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILINGS AND ALL. WALLS LOCATED AT APT LC, 1st APARTMENT FROM SOUTH AT WESTMar 5, 2022
Nov 30, 2021AApt LC · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD. FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT LC, 1st APARTMENT FROM SOUTH AT WESTMar 5, 2022
Nov 30, 2021AApt LC · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL AND. RETURN BUZZER. FROM VESTIBULE TO THE PANEL IN THE FOYER LOCATED AT APT LC, 1st APARTMENT FROM SOUTH AT WESTMar 5, 2022
Nov 30, 2021AApt LC · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR AT ENTRANCE IN THE BATHROOM LOCATED AT APT LC, 1st APARTMENT FROM SOUTH AT WESTMar 5, 2022

Showing 60 of 67. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Oct 30, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of CorrectionOpen
Oct 21, 2026DOB SafetyAEUHAZ: Open
Oct 6, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT WINDOW FRAME AT EAST WALL IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18977563 ISSUED 03-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMOpen
Sep 30, 2026DOB SafetyAEUHAZ: Open
Sep 28, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Sep 28, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Sep 28, 2026HPD C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCK AND ITS ASSEMBLIES AT APARTMENT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Sep 28, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE 1st ROOM FROM EAST LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Sep 28, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RUBBER GASKETS AT UPPER AND LOWER REFRIGERATOR DOORS IN THE KITCHEN LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Sep 28, 2026HPD B§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NOROpen
Sep 28, 2026HPD B§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THATS IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 6th STORY, 1st APARTMENT FROM WEST AT NORTOpen
Sep 16, 2026ECBConstruction: NOTED AT THE TIME OF INSPECTION, A LARGE ACCUMULATION OF DEBRIS AND CONSTRUCTION MATERIALS WAS OBSERVED OBSTRUCTING THE SCAFFOLD ENTRYWAY AT EXPOSURE #1, FRONT-LEFT CORNER OF THE PROPERTY. THE OBSTRUCTED ACCESSOpen
Sep 9, 2026DOB SafetyAEUHAZ: Closed
Aug 21, 2026ECBElevators: FAILURE TO MAINTAIN ELEVATOR IN CODE COMPLAINT MANNER AS PER BC 3001.2 & 27-987 CLASS 1 VIOLATION: EMERGENCY COMMUNICATION DEVICE INOPERATIVE, THIS A DEVICE IMPERATIVE FOR TENANTS SAFETY, REMEDY: FIX AND EMAILOpen
Aug 18, 2026ECBUnknown: AT THE TIME OF INSPECTION OF A 6-STORY BUILDING UNDER FACADES REPAIRS, I OBSERVED WORKERS USING PIPE SCAFFOLDING, UPON REQUESTING THE COMPETENT PERSON NON WAS ONSITE AS REQUIRE BY CODE 3314.4.5.1 AND UPON REQUEClosed
Aug 18, 2026ECBUnknown: AT TIME OF INSPECTION OF A 6-STORY BUILDING, I NOTICED SIDEWALK SHED ERECTED NOT MAINTAIN AS PER CODE 3307.6.5.5 & 3303.4.4.1 THROUGHOUT SIDEWALK SHED BRICKS GARBAGE BAG CONSTRUCTION DEBRIS HAS LEFT ON TOP OF SClosed
Aug 18, 2026ECBUnknown: AT TIME OF INSPECTION OF THE 6-STORY ALTERATION JOB, SUPPORTED SCAFFOLDING WAS OBSERVED ERECTED WITH LOOSE VERTICAL NETTING THAT WAS NOT PROPERLY MAINTAINED AS PER BC 3314.8.2 THIS CONDITION PRESENTS AN IMMEDIAOpen
Aug 18, 2026ECBUnknown: AT THE TIME OF INSPECTION OF A 6-STORY BUILDING UNDER FACADES REPAIRS, I OBSERVED PLASTIC JERSEY BARRIERS AND PORTA-POTTY OBSTRUCTION THE ROADWAY WHERE CAR PARK. UPON REQUEST WORKERS, RESEARCH DOT WEBSITE ANDOpen
Aug 7, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Aug 6, 2026ECBConstruction: FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED THE FOLLOWING, OBJECT STORED AT FIRE ESCAPE LANDING ON EXPOSURE 2 7TH FLOOR. REMEDY: REMOVE EGRESS OBSTRUCTION.Open
Jul 16, 2026ECBElevators: CEASE USE: DOOR RESTRICTOR INOPERATIVE. IN VIOLATION OF ASME A17.1-2013 2.14.5.7 AND 2.14.4.2. CONDITION EXPOSES THE HOISTWAY AND CONSTITUTES AN IMMEDIATE HAZARD. REPAIR AND E-MAIL THE ELEVATOR DIVISION AT EIR@Closed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 5, 2026, 3:54 AM ET. BBL 2055190091.

Look up another building