4 floors · 8 apartments · 6,916 sq ft · built 2019 · class C1 · owner of record: 280 Linden Blvd Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2018-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 68 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 84 days | Annual |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 17 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 433 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 13, 2026 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 4 STORY-BUILDING ACTIVE JOB SITE, EXTERIOR WORK AT EXPOSURE 4 WAS OBSERVED PARTIALLY COMPLETED PRIOR TO THE STOP WORK ORDER ISSUED ON 01/07/2026 UNDER REFERENCE #3A43847. THIS #39552893P | Jan 28, 2027 | $10,000 |
| Apr 13, 2026 | Unknown CLASS - 2 BC 3314.1: AT THE TIME OF INSPECTION OF A FOUR-STORY BUILDING UNDERGOING FACADE WORK, PIPE SCAFFOLD AT EXPOSURES 3 AND 4 WAS NOT MAINTAINED. LOOSE PLANKS, UNSECURED PLANKS, AND MISSING PINS WERE OBSERVED, CRE #39552898Y | Jan 28, 2027 | $2,500 |
| Mar 18, 2026 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.WORKINGAGAINST A PSWO ISSUED ON 01/07/26 UNDER PLAY NUMBER 3A43847 STOP ALL EXTERIOR WORK AT EXPOSURE 4 REAR YARDS.OBSERVED PIPE SCAFFOLD ERECTED A #35721643L | Dec 3, 2026 | $10,000 |
| Jan 5, 2026 | Unknown CLASS - 2 PERMIT HOLDER FAILED TO PROVIDE AND MAINTAIN A CONSTRUCTION SUPER FOR THE SITE WITH A VALID LICENSE. SUPER LICENSE EXPIRED 12/11/25 AND WORKERS ARE STILL ON SITE WORKING. EXPIRED LICENSE EQUATE TO NO SUPER ASSI #39548740M | Oct 26, 2026 | $2,500 |
| Jan 5, 2026 | Unknown CLASS - 2 OBSERVED AT EXPO#4 REAR OF THE BUILDING FACADE WORK IN THE PROCESS. STYROFOAM AND STUCCO WORK OPERATIONS TO BE COMPLETED. RESPONDENT FAILED TO PROVIDE ADEQUATE OVERHEAD PROTECTION FOR THE ADJOINING PROPERTY YAR #39548739P | Oct 26, 2026 | $2,500 |
| Jan 5, 2026 | Construction CLASS - 1 ACTIVE SITE. OBSERVED WORKERS THROUGHOUT THE SITE WORKING. CONSTRUCTION SUPERS LOG STATED FRAMING AND DRYWALL TO BE INSTALLED. UPON CHECKING DEPARTMENT RECORDS CONSTRUCTION SUPERS ON FILE, LICENSE EXPIRED 12/11 #39548736J | Oct 15, 2026 IN VIOLATION | $5,000 |
| Jul 29, 2025 | Unknown CLASS - 1 PROPOSING VERTICAL EXTENSION TO 8 FAMILY DWELING .OBSERVED ACTIVE SITE ,CP PRESENT UPON INSPECTION NOTED MISSING ROOF PROTECTION ON EXPOSURE 2 REAR BACK EXP 2,4 AND INADEQUATE ROOF PROTECTION ON EXPOSURE 4 (P #39542956Y | Apr 8, 2027 | $5,030 |
| Jul 29, 2025 | Construction CLASS - 2 PROPOSING VERTICAL EXTENSION TO 8 FAMILY DWELING .OBSERVED ACTIVE SITE CURRENTLY WORK ON INTERIOR FRAMING UPON REQUEST FOR C JOINTS MANUFACTURER SPECIFICATION AND SPECIAL INSPECTIONS REPORT NONE WAS PROVIDE #39542957X | Oct 6, 2026 IN VIOLATION | $1,250 |
| Jul 26, 2023 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVE 2 UNSTABLE SUB SECTION OF PLYWOOD CONSTRUCTION FENCE AT FRONT OF PREMISES, LEANING TOWARDS SIDEWALK IN DANGER OF COLLAPSING AND IS A POTENTIAL DANGER TO PUBLIC, COMPLY WITH CODE #39091188K | Oct 11, 2023 DEFAULT | $2,500 |
| Mar 1, 2023 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED STALLED/ABANDONED CONSTRUCTION SITE WITH CONSTRUCTION FENCE NOT MAINTAINED AS PER CODE. JOB SITE FENCE GATE AT EXP#1 IS LEANING TOWARD SIDEWALK. FENCE GATE HAS WITH WIDE GAPS AND #39513679M | May 10, 2023 DEFAULT | $12,500 |
| Jan 30, 2023 | Construction CLASS - 2 AT TIME OF INSPECTION FOR CLASS1 VIO#39503231P ISSUED ON 07-08-22. FOR FAILURE TO MAINTAIN SITE AS PER CODE, SITE IS CLOSED. UPON CHECKING DEPARTMENT RECORDS NO CERTIFICATE OF CORRECTION ON FILE ASSOCIATED WITH #39512259L | Apr 5, 2023 DEFAULT | $3,125 |
| Dec 20, 2022 | Construction CLASS - 2 AT TIME OF INSPECTION OF CLASS 1 VIOLATION #39506512P ISSUED ON 09/20/2022 FOR CONSTRUCTION FENCE LEANING NOT MAINTAINED WITH LARGE GAPS AT EXP. #1. OBSERVED UNSAFE/VIOLATING CONDITION HAS NOT BEEN CORRECTED. U #39510587L | Mar 1, 2023 DEFAULT | $3,125 |
| Dec 9, 2022 | Construction CLASS - 2 AT TIME OF INSPECTION FOR CLASS1 VIO#39503231P ISSUED ON 07-08-22 FOR FAILURE TO PLACE A SITE SPECIFIC SAFETY MONITORING PLAN AND MAINTAIN THE SITE PER CODE, OBSERVED SITE IS CLOSED. UNABLE TO CONFIRM COMPLIANC #39510221R | Feb 15, 2023 DEFAULT | $3,125 |
| Dec 5, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION ON A NON ACTIVE JOB SITE , I OBSERVED THAT PROJECT INFORMATION PANEL WITH GENERAL CONTRACTORS INFO AND OTHER INQUIRIES WAS NOT POSTED ON FENCE JOB PERMIT # 320908336 WAS EXPIRED SINCE #39510005M | Feb 15, 2023 DEFAULT | $3,125 |
| Dec 5, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION ON A NON ACTIVE JOB SITE, I OBSERVED CONSTRUCTION FENCE AT PREMISES NOT AT ADEQUATE HEIGHT OF 8 FEET & MISSING PANELS AT EXPOSURE 4,VIEWING PANEL NOT COVER WITH PLEXI OR SIMILAR MATER #39510002R | Feb 15, 2023 DEFAULT | $2,500 |
| Dec 5, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION ON A NON ACTIVE JOB SITE , I OBSERVED A CONSTRUCTION FENCE AT PREMISES UPON MY REVIEW THROUGH BIS FENCE PERMIT # 320908336-01-EQ-FN WAS EXPIRED SINCE 06-12-2022 AND NO NEW PERMIT WAS #39510006Y | Feb 15, 2023 DEFAULT | $3,125 |
| Sep 20, 2022 | Construction CLASS - 1 CONSTRUCTION FENCE LEANING NOT MAINTAINED WITH LARGE GAPS & OBSERVED LARGE PILE OF DEBRIS AT EXPO# 1MAINTAIN THE CONSTRUCTION FENCE & HOUSEKEEPING AT EXPO #1 #39506512P | Jan 25, 2023 DEFAULT | $6,250 |
| Sep 9, 2022 | Construction CLASS - 2 ATOI, I OBSERVED THAT THE PERMIT FOR THE CONSTRUCTION FENCE PERMIT # 320908336 HAD EXPIRED ON 06-12-19. THE FENCE IS CONCAVING TOWARD PUBLIC WALKWAY AT EXP#1. SECTION OF PANELS ARE MISSING AT EXP# 4 AT FRONT YA #39069714K | Jan 11, 2023 DEFAULT | $3,125 |
| Jul 8, 2022 | Construction CLASS - 1 DURING INSPECTION OF A SITE THAT HAS BEEN ON A STOP WORK ORDER SINCE 2019, I OBSERVED THAT THE GRASS WAS OVER GROWN, THE FENCE WAS NOT MAINTAINED, DISLODGED AND LEANING, WITH GARBAGE PILED UP IN FRONT. THERE AP #39503231P | Nov 15, 2022 DEFAULT | $6,250 |
| Jul 8, 2022 | Construction CLASS - 2 DURING INSPECTION I OBSERVED THAT THE CONSTRUCTION FENCE WAS LEANING INTO THE PEDESTRIAN WALKWAY AT EXPOSURE #1, #2 AND THE FENCE PANELS AT THE EXPOSURE #4 HAD COLLAPSED NEXT TO THE ADJACENT DRIVEWAY, GIVING E #39503229X | Nov 15, 2022 DEFAULT | $2,500 |
| Jul 8, 2022 | Construction CLASS - 2 DURING INSPECTION I OBSERVED IN THE DOB RECORDS THAT THE FENCE PERMIT HAD EXPIRED ON 06/12/2019 WITH NO RENEWAL IN PROGRESS. AS PER DOB, A PERMIT MUST BE MAINTAINED AT ALL TIMES FOR TEMPORARY EQUIPMENT THAT IS #39503230N | Nov 15, 2022 DEFAULT | $3,125 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 17) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 3:53 AM ET. BBL 3048680027.