Manhattan · Block 837 · Lot 62 · 10018

28 West 36 Street

12 floors · 58,186 sq ft · built 1911 · class O6 · owner of record: 28 West 36th Holdings Llc

26open violations
$12,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-08-19 (Accepted). Agency page

Dec 31, 2026
in 47 days
1 of 1 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 58,186 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 837). Agency page

Dec 31, 2027
in 412 days
Next due 2027
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $629,790 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2028
in 464 days
No Cycle 10 report on record yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029

Open violations

ECB / OATH (11) · $12,500 owed
IssuedViolationHearingBalance
Jun 17, 2024Construction CLASS - 2
A. C. 27-929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BUILDING 100 FEET OR MOR
#37028790Z
Jun 26, 2025
IN VIOLATION
$0
Dec 7, 2023Construction CLASS - 1
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. DOB VIOLATION #111723FA0501MH DATE 11-17-2023 TO RETAIN NYSPE AND LICENSED GC TO REPAIR FIRE ESCAPE UNDER FULL TIME NYSPE ONSITE SUPERVISION. AS TODAY 12-07-2023, WO
#35670942Y
Oct 10, 2024
DEFAULT
$12,500
Feb 28, 2023Construction CLASS - 2
27-929.1 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE FINAL SPRINKLER REPORT PREPARED BY REGISTERED DESIGNPROFESSIONAL IN OFFICE BLDG 100 FT OR MORE IN HEIGHT IN EXISTENCE ON
#37025267K
Jun 22, 2023
IN VIOLATION
$0
Nov 1, 2021Construction CLASS - 2
27-929.1 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE FINAL SPRINKLER REPORT PREPARED BY REGISTERED DESIGN PROFESSIONAL IN OFFICE BUILDING 100 FEET OR MORE IN HEIGHT IN EXIST
#37022692H
Jul 14, 2022
IN VIOLATION
$0
Jul 13, 2020Construction CLASS - 2
A.C. 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY JULY 1,2019 IN AN OFFICE BUILDING 10
#37019763Z
Mar 18, 2021
IN VIOLATION
$0
Nov 15, 2019Construction CLASS - 2
27-929.1 A.C. 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BUILDIN
#37016275X
Feb 13, 2020
STIPULATION/IN-VIO
$0
Jul 30, 2015Unknown CLASS - 2
ELECTRICAL WORK W/O A PERMIT ON 7/30/15 I OBSERVED: ELECTRICAL SIGN. ELECTRICAL SIGN HAD BEEN INSTALLED PRIOR TO INSPECTION. A ELECTRICAL PERMIT FOR SUCH SIGN WAS NOT OBTAIN. SIGN IS 1FT X 10FT W/LETTERING.
#35123491L
Dec 24, 2015
WRITTEN OFF
$0
Jul 30, 2015Unknown CLASS - 2
ELECTRICAL WORK W/O A PERMIT ON 7/30/15 @ 12:20PM I OBSERVED: NEW BRANCH CIRCUIT,FIXTURES,RECEPTACLES,SWITCHES 1ST FL STORE STYLE. AN APPLICATION FOR CERT OF ELECTRICAL INSPECTION IS NOT ON FILE. REMEDY: OBTAIN
#35159284N
Dec 24, 2015
WRITTEN OFF
$0
Jul 22, 2015Construction CLASS - 2
WORK W/O A PERMIT; INSTALLATION OF LAVATORY INSPECTION TIME: 1:20 ON 7-22-15, I OBSERVED IN COMMERCIAL SPACE ON GROUND LEVEL NAMED "IN STYLE NYC" A SMALL LAVATORY CONSISTING OF A WATER CLOSET AND BASIN.THERE
#35140764M
Sep 10, 2015
WRITTEN OFF
$0
Oct 10, 2012Plumbing CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FAILURE TO COMPLY WITH LAW FOR DRAINAGE SYSTEM PER PC702.1;27-911.OBSERVED A CRACKED 4" DRAINAGE PIPE IN BATHRM AT 8TH FLR RM800.RMDY:OBTAIN PERMIT FROM DO
#34932213P
Nov 29, 2012
IN VIOLATION
$0
Sep 4, 2008Construction CLASS - 3
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. NOTED: APPROX 84 SF6"X 6" X 3/8" WOOD FLOOR TILES ARE DISLODGED IN 2 AREAS OF THE FLOOR, ALSO THERE IS NO DOOR SADDLE. REMEDY: REPAIR/REPLACE MISSING TILES &
#34709005Z
Oct 30, 2008
WRITTEN OFF
$0
DOB (8)
IssuedViolationStatus
Nov 17, 2023CONSTRUCTION
EMERGENCY WORK ORDER DUE TO DETERIORATED FIRE ESCAPE LOCATED AT REAR FACADE SOUTH ELEVATION EXPOSURE#3 REMEDY: OWNER TO IMMEDIATELY RETAIN NYS PE+LIC GC TO REPAIR FIRE ESCAPE UNDER FULL TIME NYS PE ON SITE SUPERVISION .START WORK IMMEDIATELY AND CONTINUE DAILY UNTIL REPAIRS ARE COMPLETE.PROVIDE SAFE
#FA0501MH
DOB VIOLATION - ACTIVE
Aug 18, 2023HAZARDOUS CONDITION (FACADE)
CYCLE 9B UNSAFE REPORT FILED
#911227
DOB VIOLATION - ACTIVE
Sep 3, 2019SPRINKLER
FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019
#NRF00129
DOB VIOLATION - ACTIVE
Jun 30, 2015FACADE SAFETY PROGRAM

#HAZ85790
DOB VIOLATION - ACTIVE
Jun 30, 2015FACADE SAFETY PROGRAM

#HAZ75789
DOB VIOLATION - ACTIVE
Aug 1, 2014ELEVATOR

#9028/514899
DOB VIOLATION - ACTIVE
Aug 1, 2014ELEVATOR

#9028/514898
DOB VIOLATION - ACTIVE
Mar 13, 2003ELEVATOR
1P6073
#9013/170319
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 5)
Active
Aug 18, 2023Facades FISPHAZ
CYCLE 9B UNSAFE REPORT FILED
Active
Sep 3, 2019Sprinklers FTF-SP-FINAL
Active
Jun 30, 2015Facades FISP
CYCLE 7B UNSAFE REPORT FILED
Active
Jun 30, 2015Facades FISP
CYCLE 8B UNSAFE REPORT FILED
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 12:37 PM ET. BBL 1008370062.