Brooklyn · Block 1885 · Lot 15 · 11205

28 Skillman Street

6 apartments · 16,052 sq ft · built 2025 · class D1 · owner of record: Lot 15 Llc

8open violations
$16,150ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 800 days
Next cycle year 2028

Open violations

ECB / OATH (8) · $16,150 owed
IssuedViolationHearingBalance
Sep 27, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION I OBSERVED NO CONSTRUCTION ACTIVITY. JERSEY BARRIERS AT EXP 1 NOT INTERLOCKED NOR FILLED WITH WATER OR SAND AS PER MANUFACTURER SPECIFICATIONS CREATING A HAZARD TO THE PUBLIC AND PROPE
#39559809P
Dec 2, 2026
PENDING
$1,250
Sep 3, 2026Construction CLASS - 2
UPON INSPECTION OF AN ACTIVE 7 STORY NB CONSTRUCTION SITE I OBSERVED SAFETY ANCHOR STRAPS INSTALLED AT MULTIPLE LOCATIONS ON ALL FLOORS. UPON REQUEST TO SEE THE LOGBOOK AND INSTALL LOCATION PHOTOS FOR THE ANCHO
#39558746M
Nov 18, 2026
PENDING
$1,250
Sep 3, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1 NOT MAINTAINED IN SAFE CONDITION CONTRARY TO CODE 3307.6.5.1 SAFE CONDITION. I OBSERVED MULTIPLE LARGE HOLES IN THE DECK OF THE SIDEWALK SHED CREA
#39558773H
Nov 18, 2026
PENDING
$2,400
Sep 3, 2026Unknown CLASS - 1
UPON INSPECTION OF AN ACTIVE 7 STORY NB CONSTRUCTION SITE I OBSERVED FIRE EXTINGUISHERS SITTING ON THE FLOOR AND NOT PROPERLY INSTALLED/LOCATED ACCORDING TO THE PROVISIONS OF THE NYC FIRE CODE ON ALL FLOORS CON
#39558765H
Nov 18, 2026
PENDING
$1,250
Sep 3, 2026Construction CLASS - 1
UPON INSPECTION OF AN ACTIVE 7 STORY NB I OBSERVED MISSING TOE BOARDS AT MULTIPLE LOCATIONS ON THE ROOF, 7TH FLR, 5TH FLR, 4TH FLR, 3RD FLR AND 1ST. MISSING TOE BOARDS IS AN OVERHEAD HAZARD. NO PROTECTION TO ST
#39558772X
Nov 18, 2026
PENDING
$5,000
Sep 3, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1 WITH NOT FENCE PROJECT INFO PANEL INSTALLED FOR 28 SKILLMAN ST CONTRARY TO CODE 3301.9.1 FENCE PROJECT INFO PANEL. WHERE A SITE IS ENCLOSED WITH A FENCE I
#39558766J
Nov 18, 2026
PENDING
$1,250
Sep 3, 2026Unknown CLASS - 2
UPON INSPECTION OF AN ACTIVE 7 STORY NB CONSTRUCTION SITE I OBSERVED STANDING WATER IN THE CELLAR FLOOR OF THE STRUCTURE AT A DEPTH MORE THAN 3FT CONTRARY TO CODE 3303.14 WATER CONDITIONS. REMOVE STANDING WATER
#39558760Z
Nov 18, 2026
PENDING
$2,500
Sep 3, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1 CONTRARY TO THE APPROVED DRAWINGS. APPROX. 17FT OPEN SPAN WAS NOT ON THE APPROVED DRAWINGS. MISSING 8FT AND 10FT BAYS. HORIZONTAL PIPES AND CROSS
#39558775L
Nov 18, 2026
PENDING
$1,250
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 27, 2026ECBConstruction: AT THE TIME OF INSPECTION I OBSERVED NO CONSTRUCTION ACTIVITY. JERSEY BARRIERS AT EXP 1 NOT INTERLOCKED NOR FILLED WITH WATER OR SAND AS PER MANUFACTURER SPECIFICATIONS CREATING A HAZARD TO THE PUBLIC AND PROPEOpen
Sep 3, 2026ECBConstruction: UPON INSPECTION OF AN ACTIVE 7 STORY NB CONSTRUCTION SITE I OBSERVED SAFETY ANCHOR STRAPS INSTALLED AT MULTIPLE LOCATIONS ON ALL FLOORS. UPON REQUEST TO SEE THE LOGBOOK AND INSTALL LOCATION PHOTOS FOR THE ANCHOOpen
Sep 3, 2026ECBConstruction: UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1 NOT MAINTAINED IN SAFE CONDITION CONTRARY TO CODE 3307.6.5.1 SAFE CONDITION. I OBSERVED MULTIPLE LARGE HOLES IN THE DECK OF THE SIDEWALK SHED CREAOpen
Sep 3, 2026ECBUnknown: UPON INSPECTION OF AN ACTIVE 7 STORY NB CONSTRUCTION SITE I OBSERVED FIRE EXTINGUISHERS SITTING ON THE FLOOR AND NOT PROPERLY INSTALLED/LOCATED ACCORDING TO THE PROVISIONS OF THE NYC FIRE CODE ON ALL FLOORS CONOpen
Sep 3, 2026ECBConstruction: UPON INSPECTION OF AN ACTIVE 7 STORY NB I OBSERVED MISSING TOE BOARDS AT MULTIPLE LOCATIONS ON THE ROOF, 7TH FLR, 5TH FLR, 4TH FLR, 3RD FLR AND 1ST. MISSING TOE BOARDS IS AN OVERHEAD HAZARD. NO PROTECTION TO STOpen
Sep 3, 2026ECBConstruction: UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1 WITH NOT FENCE PROJECT INFO PANEL INSTALLED FOR 28 SKILLMAN ST CONTRARY TO CODE 3301.9.1 FENCE PROJECT INFO PANEL. WHERE A SITE IS ENCLOSED WITH A FENCE IOpen
Sep 3, 2026ECBUnknown: UPON INSPECTION OF AN ACTIVE 7 STORY NB CONSTRUCTION SITE I OBSERVED STANDING WATER IN THE CELLAR FLOOR OF THE STRUCTURE AT A DEPTH MORE THAN 3FT CONTRARY TO CODE 3303.14 WATER CONDITIONS. REMOVE STANDING WATEROpen
Sep 3, 2026ECBConstruction: UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1 CONTRARY TO THE APPROVED DRAWINGS. APPROX. 17FT OPEN SPAN WAS NOT ON THE APPROVED DRAWINGS. MISSING 8FT AND 10FT BAYS. HORIZONTAL PIPES AND CROSSOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)