3 floors · 3,777 sq ft · built 1923 · class G2 · owner of record: 20-50 Powell Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 16 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 68 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 13, 2026 | Construction CLASS - 2 WORK WITHOUT PERMIT, I OBSERVED WORKERS DISCONNECTING GAS PIPING AND DISMOUNTING SPACE HEATER ON ARRIVAL. NEW SPACE HEATER ON SITE, ALL WORK BEING PERFORMED IN STEEL FRAME GARAGE. STOP ALL PLUMBING WORK THROUGH #39173614N | Apr 22, 2026 IN VIOLATION | $0 |
| Jan 9, 2026 | Construction CLASS - 2 WORK WITHOUT PERMIT, GAS PIPING AND HEATERS IN STEEL FRAME GARAGE WAS DONE WITH NO PERMITS FILED WITH DOB. GAS METER WAS SHUT AND LOCKED BY UTILITY PRIOR TO INSPECTION., OBTAIN ALL PERMITS #39173415K | Apr 22, 2026 IN VIOLATION | $0 |
| Jan 9, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN, USE OF PVC PIPE ON EXHAUST FOR GAS FIRED HVAC SYSTEM ON 1ST 2ND AND 3RD FLOOR. USE OF PVC AS VENT FOR EXHAUST IS PROHIBITED AS PER FGC 503.4.1., REPAIR AND/OR REPLACE #39173416M | Apr 22, 2026 IN VIOLATION | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 16) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 10:05 PM ET. BBL 3036770030.