Queens · Block 839 · Lot 1 · 11102

28-31 Astoria Boulevard

15 floors · 184 apartments · 178,312 sq ft · built 2007 · class D9 · owner of record: George T. Douris Housing Development

21open violations
$1,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
56dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 56 days
Annual
Annual boiler inspection (5 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-04-17 (Accepted). Agency page

Dec 31, 2026
in 56 days
5 of 5 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 72 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $346,230 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 108 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 178,312 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 177 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 177 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 300 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 787 days
Next cycle year 2028
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 839). Agency page

Dec 31, 2029
in 1152 days
Next due 2029

Open violations

ECB / OATH (3) · $1,250 owed
IssuedViolationHearingBalance
Aug 27, 2026Construction CLASS - 2
ATOI OF A SIDEWALK SHED AT EXP 1 OF A 15 STORY RESIDENTIAL BUILDING OBSERVED MISSING PARAPET JOB INFO PANEL AS REQUIRED IN 3301.9.2 (SIDEWALK SHED PARAPET INFO PANEL) W/ THE CONTENTS REQUIRED IN 3301.9.2.1 (SWS
#39558453Z
Nov 10, 2026
$1,250
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#914787.REM:FILE ACCEPTABLE REPORT.
#37026602N
Apr 23, 2024
IN VIOLATION
$0
Apr 4, 2022Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BLDG MASONRY FACADE & APPURTENANCES.NOTE:AT THE TIME OF INSPECTION FACADE NOTED MULTIPLE DEFECTS FOR IT'S MULTIPLES EXPOSURES,SUCH AS.-(1)EXP.#1 NORTH ELEVATION(FACING HOYT AVE S.)
#35548709Z
Aug 2, 2022
IN VIOLATION
$0
DOB (2)
IssuedViolationStatus
Oct 7, 2026CONSTRUCTION
FAILURE TO MAINTAIN BLDG. OBSERVD ON THE NORTH WEST CORNER OF EXPOSURE 1 & 4 ON THE 7TH AND 11TH FLOOR MISSING MORTAR JOINTS & LOOSE BRICKS ON EXPOSURE 2 EAST ELEV: MISSING, DAMAGED MORTAR JOINTS. ROOF: MINOR CRACKS IN MORTAR JOINTS ON BULKHEAD. REMEDY: REPAIR AND/OR REPLACE DAMAGED MASONRY ON EXPOS
#SR0101RF
DOB VIOLATION - ACTIVE
Sep 13, 2022HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#910476
DOB VIOLATION - ACTIVE
DOB NOW Safety (17)
IssuedViolationStatus
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Sep 13, 2022Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 7, 2026DOBCONSTRUCTION: FAILURE TO MAINTAIN BLDG. OBSERVD ON THE NORTH WEST CORNER OF EXPOSURE 1 & 4 ON THE 7TH AND 11TH FLOOR MISSING MORTAR JOINTS & LOOSE BRICKS ON EXPOSURE 2 EAST ELEV: MISSING, DAMAGED MORTAR JOINTS. ROOF: MINOR CRACKS IN MORTAR JOINTS ON BULKHEAD. REMEDY: REPAIR AND/OR REPLACE DAMAGED MASONRY ON EXPOSOpen
Aug 27, 2026ECBConstruction: ATOI OF A SIDEWALK SHED AT EXP 1 OF A 15 STORY RESIDENTIAL BUILDING OBSERVED MISSING PARAPET JOB INFO PANEL AS REQUIRED IN 3301.9.2 (SIDEWALK SHED PARAPET INFO PANEL) W/ THE CONTENTS REQUIRED IN 3301.9.2.1 (SWSClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 5, 2026, 5:57 PM ET. BBL 4008390001.