Brooklyn · Block 1781 · Lot 58 · 11221

279 Kosciuszko Street

4 floors · 20 apartments · 18,300 sq ft · built 1931 · class C1 · owner of record: Wilson Mer Associates

25open violations
$1,562ECB/OATH penalties owed
5HPD class C (immediately hazardous)
46dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 46 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2017-08-30 (Accepted). Agency page

Dec 31, 2026
in 46 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 62 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 290 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 777 days
Next cycle year 2028

Open violations

ECB / OATH (1) · $1,562 owed
IssuedViolationHearingBalance
Oct 24, 2023Boilers CLASS - 2
SLANTFIN BOILER ROLL OUT SWITCH DEFECTIVE/FRONT BOILER JACKET NOT IN PLACE/DEBRIS IN BOILER ROOM/REMOTE SWITCH DEFECTIVE/HWH'S MISSING FLAME COVERS/STORAGE AT GAS METERS, MAINTAIN BOILER; CORRECT VIOLATION AND
#39097744J
Jun 10, 2024
DEFAULT
$1,562
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (25) · C 5 · B 18 · A 2
IssuedClassViolationCorrect by
Jun 9, 2026BApt 102 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT THE WEST WALL IN THE BATHROOM LOCATED AT APT 102, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18627052 ISSUED 07-FEB-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 2Jul 14, 2026
Mar 28, 2025CApt 203 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEED THE MAXIMUM TEMPERATURE OF 130 DEGREES AT ALL HOT WATER FIXTURE BATHROOM AND KITCHEN SINK IN THE ENTIRE APARTMENT LOCATED AT APT 203, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTApr 3, 2025
Mar 5, 2019A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING ON WALL AT PUBLIC HALL, 1st STORYJun 8, 2019
Oct 11, 2016CApt 4D · SECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM WEST AT NORTHOct 19, 2016
Oct 11, 2016BApt 4D · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE EAST WINDOW COUNTER BALANCE UPPER AND LOWER SASH IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 15, 2016
Oct 11, 2016BApt 4D · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE EAST WINDOW COUNTER BALANCE UPPER AND LOWER SASH IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 15, 2016
Oct 11, 2016CApt 4D · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOMMUNICATION SYSTEM IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 19, 2016
Sep 12, 2016BApt 4D · SECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 17, 2016
Aug 4, 2016CApt 4B · SECTION 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ... IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTAug 12, 2016
Jun 20, 2016BApt 2C · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJul 25, 2016
Jun 20, 2016BApt 2C · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF INOPPERABLE LOWER SASH WINDOW (SEALED). IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJul 25, 2016
Jun 20, 2016BApt 2C · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE REFRIGERATOR DOOR RUBBER GASKET. IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJul 25, 2016
Jun 20, 2016BApt 2C · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJul 25, 2016
Jun 20, 2016BApt 2C · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJul 25, 2016
Jun 20, 2016BApt 2C · SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASHBASIN IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJul 25, 2016
Jun 17, 2016BApt 1E · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJul 22, 2016
Jun 17, 2016BApt 1E · SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WOOD CABINET ABOVE SINK AT NORTH WALL IN THE KITCHEN LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJul 22, 2016
Jun 17, 2016BApt 1E · SECTION 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJul 22, 2016
Jun 17, 2016BApt 1E · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJul 22, 2016
Jul 25, 2014BApt 1E · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTHAug 29, 2014
Jun 20, 2013BApt 1C · SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''1''Jul 25, 2013
Dec 1, 2004CApt 1C · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL, WEST WALL, 1st WINDOW FRAME FROM NORTH AT EASTDec 27, 2004
Aug 14, 2002AApt 3D · SECTION 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO HEAVY DUTY LATCH SET ; CHAIN DOOR GUARD; IN THE FOYER LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHNov 22, 2002
Jun 24, 2002BApt 1A · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE REGLAZE PORCELIAN IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTAug 3, 2002
Feb 6, 1990BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER CEILING CELLAR THRU OUT.Mar 26, 1990

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 9:25 AM ET. BBL 3017810058.

Look up another building