Bronx · Block 4514 · Lot 26 · 10467

2770 Matthews Avenue

4 floors · 7 apartments · 5,073 sq ft · built 1931 · class C1 · owner of record: Mat 2770 Llc

5open violations
$25,000ECB/OATH penalties owed
1HPD class C (immediately hazardous)
60dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 60 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 76 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 304 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 425 days
Next cycle year 2027

Open violations

ECB / OATH (8) · $25,000 owed
IssuedViolationHearingBalance
Oct 24, 2022Site Safety CLASS - 1
AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE #1 WITH PUMP JACK INSTALLED ON TOP WITH WORKERS PERFORMING CONSTRUCTION OPERATIONS ON PUMP JACK. UPON REQUEST OF LOAD IMPOSE LETTER FOR SIDEWA
#39508130Z
Jan 6, 2023
IN VIOLATION
$625
Oct 24, 2022Construction CLASS - 1
OBSERVED THAT COMPETENT PERSON ONSITE WAS CONDUCTING DAILY SUPPORTED SCAFFOLD INSPECTIONS WITHOUT 32 HOUR ERECTOR OSHA TRAINING CERTIFICATE. STOP ALL USE OF SUPPORTED SCAFFOLD
#39508126X
Sep 21, 2023
IN VIOLATION
$5,000
Aug 4, 2022Construction CLASS - 1
OBSERVED CONSTRUCTION SUPER LOG BOOK PROVIDED BY CONSTRUCTION MANAGER A.DAVIDOV, CONST.SUPER ON PERMIT J.MENDEL LAST SIGNED BOOK 7/1/22, LOG BOOK THEN SIGNED BY CONST.SUPER M.HALIM AND S.PATHIER WITH NOTE AT BE
#39504622R
Sep 30, 2022
IN VIOLATION
$625
Jul 6, 2022Construction CLASS - 1
NOTE: OBSERVED UNSAFE SUPPORTED SCAFFOLD HAVE LOOSE PLANK, NOT TIEDOWN, NO GUARD RAILS, NOT FULLY PLANKED AT EXP1, 4, CREATING PLANK ITSELF FALL HAZARD TO STREET.STOP ALL USE OF SUPPORTED SCAFFOLD, PROVIDE SAFE
#39503147M
Dec 9, 2022
IN VIOLATION
$1,250
Jul 6, 2022Construction CLASS - 1
NOTE: UNSAFE WORKING PLATFORM BUILT AT 1ST FLOOR OPENING USING SCAFFOLD FRAME & PLANK, HANGING WITH WALL USING U-CLAMP ABOUT 10FT ABOVE FROM CELLAR FLOOR, NO DESIGN DRAWING(BC3301.6) CREATING COLLAPSED HAZARD.S
#39503139M
Dec 9, 2022
IN VIOLATION
$2,500
Jun 6, 2022Construction CLASS - 1
OBSERVED AT EXP1, PIPE SCAFFOLDING ERECTED ALMOST ATTACHED OR ATTACHED WITH HIGH VOLTAGE ELECTRICAL LINE ON A 4STY BUILDING UNDER CONSTRUCTION. CREATING ELECTROCUTION HAZARD WHOLE SCAFFOLDING, SIDEWALK SHED, BU
#39501938J
Oct 12, 2022
IN VIOLATION
$10,000
Apr 8, 2022Construction CLASS - 1
I OBSERVED ACTIVE WORKSITE AT SUPERSTRUCTURE PHASE CURRENTLY AT THE ROOF LEVEL. NO GUARDRAILS IN PLACE ON THE WORKING DECK(ROOF)NO CAZ. ONLY 1 WORKER OUT OF 3 WAS WEARING P.F.A.S. HAZARD OF FALLING AND SERIOUS
#39500422Y
Jun 3, 2022
IN VIOLATION
$2,500
Apr 8, 2022Construction CLASS - 1
SUPPORTED SCAFFOLD(SF) NEAR POWERLINESI OBSERVED SF AT EXP 1, 2 AND 4. SF WITHIN 10F-OSHA-1926.541(F)(6)- FROM POWERLINES THAT ARE NOT PROTECTED(PLASTIC YELLOW COVER). HAZARD OF ELECTROCUTION EXISTS FOR WORKER
#39500423X
Jun 3, 2022
IN VIOLATION
$2,500
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (5) · C 1 · B 0 · A 4
IssuedClassViolationCorrect by
Jun 30, 2026A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME READILY ACCESSIBLE FOR SIGNATURE, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT THAT MISSING AT PUBLIC HALL, 1st STORYOct 3, 2026
Feb 19, 2025C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN PRESENT, MISSING INFORMATION IS IN BLANK AT PUBLIC HALL, 1st STORYFeb 25, 2025
Feb 19, 2025A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORYMay 25, 2025
Feb 19, 2025A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYMay 25, 2025
Feb 19, 2025A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYMay 25, 2025

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 1, 2026, 11:27 AM ET. BBL 2045140026.