Manhattan · Block 877 · Lot 1 · 10010

277 Park Avenue South

1 floors · 42,944 sq ft · built 1890 · class M1 · owner of record: Calvary Prot Epis Chu

14open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
42dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 42 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 42 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 42,944 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 163 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 163 days
Annual filing
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-17 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Dec 15, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING FACADE WALL"S" AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION I OBSERVED AT EX #1, SOUTH ELEVATION, CRACKED/BROKEN GLASS WINDOW AT 7TH FLOOR. CONCRETE AT 1ST FLOOR ABOVE MAIN DO
#35726330N
Feb 19, 2026
DEFAULT
$0
DOB (4)
IssuedViolationStatus
Aug 1, 2024FAILURE TO CORRECT SWARMP CONDITIONS (FACADE)
FAILURE TO CORRECT SWARMP CONDITIONS
#00063
DOB VIOLATION - ACTIVE
May 2, 2024FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00169
DOB VIOLATION - ACTIVE
Feb 19, 2024HAZARDOUS CONDITION (FACADE)
CYCLE 9B UNSAFE REPORT FILED
#911500
DOB VIOLATION - ACTIVE
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#00243
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
Aug 1, 2024Facades FISPFCS
FAILURE TO CORRECT SWARMP CONDITIONS
Active
May 2, 2024Benchmarking - LL84 FTF-EN-BENCH
Active
Feb 19, 2024Facades FISPHAZ
CYCLE 9B UNSAFE REPORT FILED
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
HPD (4) · C 1 · B 3 · A 0
IssuedClassViolationCorrect by
Mar 6, 2014CSECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES AT COMMUNITY KITCHEN, 3rd STORYMar 6, 2014
Mar 6, 2014BSECTION 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES ... AT 1st COMMUNITY BATHROOM FROM NORTH, 4th STORYApr 10, 2014
Jul 7, 2008BD26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS 4TH STY EAST WING EAST ROOM.Aug 11, 2008
Jul 7, 2008BD26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS 3RD STY WEST WING SOUTH WEST ROOM.Aug 11, 2008

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 19, 2026, 8:17 AM ET. BBL 1008770001.