12 floors · 97 apartments · 153,653 sq ft · built 1911 · class D3 · owner of record: Weinreb, Jacob As Co-Trustee
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 69 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 85 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 153,653 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 190 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 190 days | Annual filing |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $6,585,750 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2028 in 486 days | No Cycle 10 report on record yet |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1888). Agency page | Dec 31, 2028 in 800 days | Next due 2028 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1165 days | Next cycle year 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-15 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 7, 2026 | Construction CLASS - 2 DEPARTMENT OF BUILDINGS WEATHER ADVISORY ISSUED 06/05/2026 FOR FORECASTED HIGH WINDS. A PORTION OF THE SIDEWALK SHED AT EXPOSURE #1 BECAME DISLODGED AND FELL INTO THE STREET, CAUSING DAMAGE TO VEHICLE(S). SITE #39555132Y | Mar 15, 2027 PENDING | $5,000 |
| Jun 7, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, AN INCIDENT INVOLVING A DISLODGED PORTION OF A SIDEWALK SHED OCCURRED AT THE CONSTRUCTION SITE, RESULTING IN DAMAGE TO VEHICLE(S) AND REQUIRING RESPONSE BY NYPD AND EMERGENCY RESPONSE PER #39555133X | Mar 15, 2027 | $5,000 |
| Jun 6, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN. DURING HIGH WIND EVENT SIDEWALK SHED PARTIALLY COLLAPSED, DROPPING WOODEN PANELS AND METAL SHEATHING TO GROUND DAMAGINGMULTIPLE VEHICLES. REMEDY: REPAIR AND/OR REPLACE. #35721753M | Mar 11, 2027 PENDING | $12,500 |
| Apr 20, 2026 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7B, 8B, AND 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #906584. AGG1: PRIOR NOV 37026272J #37036513K | Feb 25, 2027 PENDING | $3,125 |
| Jan 16, 2024 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7B AND 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #806584. REMEDY: FILE ACCEPTABLE REPORT. #37026272J | May 23, 2024 IN VIOLATION | $0 |
| Jul 2, 2021 | Construction CLASS - 1 BC3307649-AVOID INTERFERENCE.NOTE:AT TIME OF INSPECTION AT 12 STORY FULLY OCCUPIED BUILDING I OBSERVED SIDEWALK SHED ERECTED AND CROSSWALK/CORNER DID NOT HAVE REQUIRED 5 FOOT CLEARANCE.CLEARANCE AT SITE WAS 3 F #35575041L | Jan 20, 2022 IN VIOLATION | $625 |
| Nov 6, 2019 | Construction CLASS - 3 FENCE EXCEEDS PERMITTED HEIGHT. NOTED, AT THE TIME OF INSPECTION OBSERVED THE SIDE AND BACKYARD FENCES HIGHER THAN 6FT (AROUND 12 FT CHAIN LINK FENCE) HAS BARBED WIRE ON THE END., CONFORM FENCE TO HEIGHT REQUIR #39012395P | Jun 3, 2021 IN VIOLATION | $0 |
| Aug 1, 2018 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#806584/REM:FILE ACCEPTABLE REPORT. #37012243N | Jun 27, 2019 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #01708 | DOB VIOLATION - ACTIVE |
| Jan 23, 2023 | HAZARDOUS CONDITION (FACADE) CYCLE 9B UNSAFE REPORT FILED #910658 | DOB VIOLATION - ACTIVE |
| Aug 21, 2020 | ELEVATOR #9028/680770 | DOB VIOLATION - ACTIVE |
| Aug 21, 2020 | ELEVATOR #9028/680771 | DOB VIOLATION - ACTIVE |
| Jul 3, 2019 | ELEVATOR #9028/657236 | DOB VIOLATION - ACTIVE |
| Jul 3, 2019 | ELEVATOR #9028/657237 | DOB VIOLATION - ACTIVE |
| Jun 25, 2015 | FACADE SAFETY PROGRAM #HAZ75641 | DOB VIOLATION - ACTIVE |
| Jun 25, 2015 | FACADE SAFETY PROGRAM #HAZ85642 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2023 | Facades FISPNRF CYCLE 9B NO REPORT FILED | Active |
| Jan 23, 2023 | Facades FISPHAZ CYCLE 9B UNSAFE REPORT FILED | Active |
| Jun 25, 2015 | Facades FISP CYCLE 8B UNSAFE REPORT FILED | Active |
| Jun 25, 2015 | Facades FISP CYCLE 7B UNSAFE REPORT FILED | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 31, 2026 | B | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT 1ST STACK AT EAST EXTERIOR WALL AT FIRE ESCAPE | Oct 5, 2026 |
| Aug 31, 2026 | A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Dec 4, 2026 |
| Aug 31, 2026 | B | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. | Oct 5, 2026 |
| Jul 2, 2026 | C | Apt 3A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 28, 2026 |
| Sep 25, 2023 | C | Apt 1H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1H, 1st BSMT-APT FROM WEST AT NORTH | Oct 21, 2023 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 31, 2026 | HPD B | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT 1ST STACK AT EAST EXTERIOR WALL AT FIRE ESCAPE | Open |
| Aug 31, 2026 | HPD A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Open |
| Aug 31, 2026 | HPD B | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 2, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Closed |
| Jul 2, 2026 | HPD B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE EAST YARD | Closed |
| Jul 2, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FEET AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Closed |
| Jul 2, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Jul 2, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Closed |
| Jul 2, 2026 | HPD B | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)