Manhattan · Block 1721 · Lot 70 · 10027

276 Lenox Avenue

7 floors · 59,521 sq ft · built 1918 · class W1 · owner of record: Hva 124, Llc

25open violations
$10,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
183dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 59,521 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 183 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 183 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 793 days
Next cycle year 2028
Energy audit and retro-commissioning (2031) Likely applies
Local Law 87 · Calendar year 2031
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1721). Agency page

Dec 31, 2031
in 1888 days
Next due 2031
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $210,000 in late-filing or failure-to-file penalties. Agency page

On fileCycle 10 filing on record: SWARMP (2026-03-30)

Open violations

ECB / OATH (4) · $10,000 owed
IssuedViolationHearingBalance
Aug 24, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES. NOTE: OBSERVED AT TIME OF INSPECTION, AT EXPOSURE 4(WEST) CRACK VERTICAL ACROSS MULTIPLE BRICKS, AS WELL AS POINTING ABOVE MISSING AND STARTING TO
#35731030H
Oct 29, 2026
PENDING
$5,000
Nov 3, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION I OBSERVED EXP #1 NORTH-HAIRLINE CRACKS AT BANDING/CORNICE MULTI LOC.-EXP #3 SOUTH(1) CRACKED/SPALLING BRICK PARAPET LEVEL
#35718050Z
Jan 8, 2026
IN VIOLATION
$5,000
Jun 23, 2025Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR WALLS FACADE AND APPURTENANCES: OBSERVED AT EXPOSURE 1 NORTH ELEVATION DEFECT AT 6TH AND 7TH FLOOR CORNICE: CRACK SPALLING AND DAMAGE METAL TRIM. CRACK AT 1ST FLOOR AND DEFECTED STU
#35718105R
Aug 28, 2025
IN VIOLATION
$0
Apr 8, 2025Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #906154. REMEDY: SUBMIT ACCEPTABLE REQU
#37034680Z
Aug 7, 2025
IN VIOLATION
$0
DOB (7)
IssuedViolationStatus
Jun 23, 2024FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023)
#00107
DOB VIOLATION - ACTIVE
Feb 22, 2024NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
#00363
DOB VIOLATION - ACTIVE
Aug 21, 2022FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2021
#10156
DOB VIOLATION - ACTIVE
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2001219
DOB VIOLATION - ACTIVE
Nov 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00189
DOB VIOLATION - ACTIVE
Aug 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00373
DOB VIOLATION - ACTIVE
May 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00373
DOB VIOLATION - ACTIVE
DOB NOW Safety (14)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Jun 23, 2024Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Feb 22, 2024Facades FISPNRF
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Report
Active
Aug 21, 2022Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Nov 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
May 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Aug 24, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES. NOTE: OBSERVED AT TIME OF INSPECTION, AT EXPOSURE 4(WEST) CRACK VERTICAL ACROSS MULTIPLE BRICKS, AS WELL AS POINTING ABOVE MISSING AND STARTING TOOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 4:59 AM ET. BBL 1017210070.