4 floors · 42,288 sq ft · built 1930 · class N2 · owner of record: Concourse House Hdfc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 42,288 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-10 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 21, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED VIOLATING CONDITION HAS BEEN CORRECTED. HOWEVER, NO CERTIFIC #39201407X | Oct 30, 2026 PENDING | $1,250 |
| Jan 3, 2024 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS#39085749K ISSUED ON 05/08/23 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01, COMPLY WITH COMMISS #39102659Z | Apr 19, 2024 IN VIOLATION | $0 |
| Sep 26, 2023 | Construction CLASS - 2 OBSERVED THROUGHOUT BUILDING NEWLY INSTALLED EXTENSION COUPLINGS FOR SPRINKLERS AND NEWLY INSTALLED SPRINKLER HEADS. NO PERMITS ON FILE AT THE DOB FOR THIS INSTALLATION., OBTAIN ALL PERMITS #39095784P | Jan 5, 2024 IN VIOLATION | $0 |
| Sep 26, 2023 | Construction CLASS - 2 EMERGENCY EXIT SELF-CLOSING DOORS DO NOT CLOSE PROPERLY AND OR LATCH COMPLETELY CLOSE, LOCATED AT ROOF LEVEL BULKHEAD(STAIRCASE A), 1 FLOOR UNIT BALCONY, (EXPOSURE 3), AND ALL 3 EMERGENCY EXIT DOORS, 1ST LEVEL #39095790L | Jan 5, 2024 IN VIOLATION | $0 |
| Sep 26, 2023 | Construction CLASS - 2 ILLEGAL CEILING PLASTIC ACCESS PANEL INSTALLED AND IMPROPER FIRE STOPPING LOCATED AT STAIRCASE B 4TH FLOOR., PROVIDE/MAINTAIN FIRE STOPPING #39095791N | Jan 5, 2024 IN VIOLATION | $0 |
| May 8, 2023 | Unknown CLASS - 1 I OBSERVED IN THE ELECTRICAL ROOM THE INSTALLATION OF DATA/NETWORK WIRING AND EQUIPMENT IN A BLACK CABINET. NO EQUIPMENT OTHER THAN ELECTRICAL DISTRIBUTION EQUIPMENT IS PERMITTED IN THE ELECTRICAL ROOMS/ CLOSET #39085749K | Jan 16, 2024 IN VIOLATION | $0 |
| May 8, 2023 | Unknown CLASS - 2 I OBSERVED IN THE BASEMENT ELECTRICAL ROOM , CONDUITS, JUNCTION BOXES, RECPTACLES TO SUPPLY POWER TO THE DATA/ NETWORK EQUIPMENT INSTALLED IN A BLACK CABINET. NO PERMITS ON FILE UN DOB RECORDS COVER THE AFOREME #39085754P | Jan 29, 2024 IN VIOLATION | $0 |
| May 8, 2023 | Unknown CLASS - 2 I OBSERVED ON THE 2ND FLOOR EMERGENCY EXIT BALCONY AND BASEMENT BOILER ROOM CONVENIENCE RECEPTACLES NOT OF THE GFCI TYPE NOR GFCI PROTECTED AS REQUIRED FOR OUTLETS INSTALLED OUTDOORS. PHOTOS TAKEN, INSTALL GFC1 #39085750H | Jan 29, 2024 IN VIOLATION | $0 |
| Jun 10, 2021 | Boilers CLASS - 2 EXPOSE ELECT. COND. RETURN TANK-SAFETY DISCH. NOT SUPPORTED-DRESSER COUPLING, PROHIB. FITTING STEAM PIPING-CONDENSATE, MAKE UP TANKS CORRO., LEAKING-BRAIDED CONNECT. OIL PUMP NOT CODE-BAROMETRIC DAMPER DEFECTIV #39042593N | Oct 8, 2021 IN VIOLATION | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 21, 2026 | ECB | Construction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED VIOLATING CONDITION HAS BEEN CORRECTED. HOWEVER, NO CERTIFIC | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 7:13 PM ET. BBL 2033150001.