17 floors · 733,250 sq ft · built 2025 · class Y3 · owner of record: Nyc Department Of Corrections
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $190,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 114 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 733,250 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 183 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 183 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1158 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 175). Agency page | Dec 31, 2035 in 3349 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 7, 2026 | Unknown CLASS - 2 3301.6 MANUFACTURER SPECIFICATIONS, DESIGN, AND CAPACITY. ATOI IN RESPONSE TO INCIDENT WHERE ELECTRICIAN INJURED HIS HAND DURING AN ELECTRICAL PULL BOX LIFTING OPERATION, NO DESIGN DRAWINGS, MANUFACTURER SPECS #39560312H | Dec 16, 2026 PENDING | $2,500 |
| Oct 7, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION WHEN RESEARCHING PRESHIFT MEETING TO DETERMINE THE SCOPE OF WORK THAT LEAD TO WORKER INJURING HIS HAND OBSERVED NO MENTION OF PULLEY SYSTEM OR USE OF PULLEY SYSTEM OR IDENTIFIED HAZARDS FO #39560313J | Dec 16, 2026 PENDING | $5,000 |
| Sep 26, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION OBSERVED: VERTICAL NETTING NOT MAINTAINED AS PER BC 3308.5 EXPOSURE# 4 AT 12, 13 AND 14 FL. CREATING A POTENTIAL SAFETY HAZARDOUS CONDITION FOR PUBLIC AND PROPERTY. MATERIALS, TOOLS, AND D #39559776H | Dec 2, 2026 PENDING | $5,000 |
| Aug 25, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED MONOKOTE FIREPROOFING DEBRIS ON THE ROOF AND 2ND-FLOOR PATIO OF ADJACENT PROPERTY AT 53 BOERUM PLACE. DEBRIS ORIGINATING FROM THE CONSTRUCTION SITE MIGRATED BEYOND THE SITE DUE T #39558402Z | Nov 4, 2026 PENDING | $25,000 |
| Aug 4, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, MAKESHIFT TEMPORARY PLATFORMS WERE OBSERVED ON STAIRCASES AT THE 17TH FLOOR. UPON REQUEST FOR DESIGN DRAWINGS, NONE WERE PROVIDED, CONTRARY TO BC 3301.6.5. STOP USE OF THE TEMPORARY PLATF #39557493Z | May 18, 2027 PENDING | $5,000 |
| Aug 4, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, WHILE RESPONDING TO AN INCIDENT INVOLVING A WORKER WHO SLIPPED AND FELL DURING STRIPPING OPERATIONS AT THE ELEVATOR SHAFT ON THE 14TH FLOOR, SCAFFOLD PLATFORMS WERE NOT FULLY PLANKED, NO #39557492R | May 18, 2027 PENDING | $10,000 |
| Jul 22, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, MONOKOTE FIREPROOFING SPRAY OPERATIONS WERE CONDUCTED WITHOUT ADEQUATE CONTAINMENT. MONOKOTE DEBRIS ORIGINATING FROM THE SITE WAS OBSERVED AT 53 BOERUM PLACE. FAILURE TO CONTAIN AIRBORNE #39556934K | Apr 9, 2027 PENDING | $10,000 |
| Jul 1, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED POWDER-ACTUATED FASTENER PINS AND SPENT POWDER-ACTUATED CARTRIDGE CASINGS ON THE NEIGHBORING PROPERTY, INDICATING CONSTRUCTION DEBRIS WAS NOT CONTAINED, CREATING A HAZARDOUS COND #39556045K | Apr 9, 2027 PENDING | $10,000 |
| Jun 25, 2026 | Unknown CLASS - 1 WORKER CUT HAND WHILE USING REBAR BENDING MACHINE FOR REBAR OPERATION, ON A 17 STORY NB SITE. PERMIT HOLDER JOB# B00939362-I1-GC, FAILED TO SUBMIT REPORT WITHIN 3 BUSINESS DAYS OF REQUIRED 16 ITEMS TO CODE 28-1 #39555895M | May 14, 2027 PENDING | $10,000 |
| Jun 17, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, MONOKOTE FIREPROOFING SPRAY OPERATIONS WERE CONDUCTED WITHOUT ADEQUATE CONTAINMENT. MONOKOTE DEBRIS ORIGINATING FROM THE SITE WAS OBSERVED AT 53 BOERUM PLACE AND 321 ATLANTIC AVENUE. FAIL #39555646L | May 13, 2027 PENDING | $10,000 |
| May 21, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED DEBRIS INCLUDING BUCKETS AND OTHER CONSTRUCTION MATERIAL FROM 275 ATLANTIC AVENUE HAD FALLEN ONTO THE ROOF AND ACCESSIBLE PATIO AREA OF 53 BOERUM PLACE, CREATING A STRUCK-BY HAZA #39554499X | Mar 1, 2027 PENDING | $10,000 |
| May 21, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED GENERAL CONTRACTOR FAILED TO IMMEDIATELY NOTIFY THE DEPARTMENT AFTER BEING INFORMED CONSTRUCTION DEBRIS FROM 275 ATLANTIC AVENUE IMPACTED THE ROOF AND ACCESSIBLE PATIO OF NEIGHBO #39554498Y | Mar 1, 2027 PENDING | $5,000 |
| May 21, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED EXCESSIVE CONSTRUCTION DEBRIS, INCLUDING SPRAY FOAM AND MISCELLANEOUS MATERIAL, ACCUMULATED OUTSIDE VERTICAL SAFETY NETTING SYSTEMS AND ALONG PERIMETER EDGES, CONTRARY TO HOUSEKE #39554500Y | Mar 1, 2027 PENDING | $2,500 |
| May 21, 2026 | Site Safety CLASS - 1 AT TIME OF INSPECTION, OBSERVED FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS REQUIRING ALL LOOSE DEBRIS AND CONSTRUCTION MATERIALS BE SECURED DUE TO FORECASTED SEVERE WEATHER AND HIGH WINDS WITH GUSTS UP TO 60 #39554502H | Mar 1, 2027 PENDING | $10,000 |
| May 21, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, OBSERVED HORIZONTAL SAFETY NETTING SYSTEMS AND AREAS NEAR UNENCLOSED PERIMETERS WERE NOT MAINTAINED FREE OF DEBRIS THROUGHOUT THE WORKDAY, WITH PLASTIC BUCKET, SPRAY FOAM MATERIAL, AND MI #39554501X | Mar 1, 2027 PENDING | $5,000 |
| May 21, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED SITE SAFETY MANAGER WAS MADE AWARE CONSTRUCTION DEBRIS FROM 275 ATLANTIC AVENUE IMPACTED NEIGHBORING PROPERTY AT 53 BOERUM PLACE, CREATING A HAZARDOUS CONDITION TO OCCUPANTS AND #39554497M | Mar 1, 2027 PENDING | $2,500 |
| May 18, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OF A PROPOSED 22-STORY NEW BUILDING, I OBSERVED SPRAY FIREPROOFING MATERIALS PARTICLES/DEBRIS FROM CONSTRUCTION SITE ON ADJOINING STREETS AND NEIGHBORHOOD. THIS IS A RE-OCCURRING VIOLA #39554248L | Jan 22, 2027 PENDING | $5,000 |
| Issued | Violation | Status |
|---|---|---|
| Mar 19, 2014 | ELEVATOR NYC DEPARTMENT OF CORRECTIONS #9027/503742 | DOB VIOLATION - ACTIVE |
| Mar 29, 2011 | ELEVATOR #9028/373779 | DOB VIOLATION - ACTIVE |
| Apr 26, 2010 | ELEVATOR #9027/331824 | DOB VIOLATION - ACTIVE |
| Feb 9, 2009 | ELEVATOR #9011/295354 | DOB VIOLATION - ACTIVE |
| Sep 24, 2008 | ELEVATOR #9011/279058 | DOB VIOLATION - ACTIVE |
| Jul 9, 1998 | CONSTRUCTION HAZARDOUS #05H02 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #02449 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 29, 2017 | Facades FISP CYCLE 8A UNSAFE REPORT FILED | Active |
| Feb 21, 2012 | Facades LL11/98 UNSAFE LOCAL LAW REPORT FILED | Active |
| May 23, 2008 | Facades LL11/98 CYCLE 6 UNSAFE REPORT FILED | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 7, 2026 | ECB | Unknown: 3301.6 MANUFACTURER SPECIFICATIONS, DESIGN, AND CAPACITY. ATOI IN RESPONSE TO INCIDENT WHERE ELECTRICIAN INJURED HIS HAND DURING AN ELECTRICAL PULL BOX LIFTING OPERATION, NO DESIGN DRAWINGS, MANUFACTURER SPECS | Open |
| Oct 7, 2026 | ECB | Unknown: AT TIME OF INSPECTION WHEN RESEARCHING PRESHIFT MEETING TO DETERMINE THE SCOPE OF WORK THAT LEAD TO WORKER INJURING HIS HAND OBSERVED NO MENTION OF PULLEY SYSTEM OR USE OF PULLEY SYSTEM OR IDENTIFIED HAZARDS FO | Open |
| Sep 26, 2026 | ECB | Unknown: AT TIME OF INSPECTION OBSERVED: VERTICAL NETTING NOT MAINTAINED AS PER BC 3308.5 EXPOSURE# 4 AT 12, 13 AND 14 FL. CREATING A POTENTIAL SAFETY HAZARDOUS CONDITION FOR PUBLIC AND PROPERTY. MATERIALS, TOOLS, AND D | Open |
| Sep 15, 2026 | ECB | Unknown: AT TIME OF INSPECTION OF A 22 STORY BUILDING OBSERVED WORKER STANDING ON A MAKESHIFT PLATFORM ON THE GUARDRAILS OF A JLG 1930ES SCISSOR LIFT AT 4TH FLOOR LEVEL. WORKER WAS SEEN ABOVE THE GUARDRAIL AND NOT TIED | Closed |
| Aug 25, 2026 | ECB | Construction: AT TIME OF INSPECTION, OBSERVED MONOKOTE FIREPROOFING DEBRIS ON THE ROOF AND 2ND-FLOOR PATIO OF ADJACENT PROPERTY AT 53 BOERUM PLACE. DEBRIS ORIGINATING FROM THE CONSTRUCTION SITE MIGRATED BEYOND THE SITE DUE T | Open |
| Aug 4, 2026 | ECB | Unknown: AT TIME OF INSPECTION, MAKESHIFT TEMPORARY PLATFORMS WERE OBSERVED ON STAIRCASES AT THE 17TH FLOOR. UPON REQUEST FOR DESIGN DRAWINGS, NONE WERE PROVIDED, CONTRARY TO BC 3301.6.5. STOP USE OF THE TEMPORARY PLATF | Open |
| Aug 4, 2026 | ECB | Construction: AT TIME OF INSPECTION, WHILE RESPONDING TO AN INCIDENT INVOLVING A WORKER WHO SLIPPED AND FELL DURING STRIPPING OPERATIONS AT THE ELEVATOR SHAFT ON THE 14TH FLOOR, SCAFFOLD PLATFORMS WERE NOT FULLY PLANKED, NO | Open |
| Jul 22, 2026 | ECB | Construction: AT TIME OF INSPECTION, MONOKOTE FIREPROOFING SPRAY OPERATIONS WERE CONDUCTED WITHOUT ADEQUATE CONTAINMENT. MONOKOTE DEBRIS ORIGINATING FROM THE SITE WAS OBSERVED AT 53 BOERUM PLACE. FAILURE TO CONTAIN AIRBORNE | Open |
| Jul 6, 2026 | ECB | Construction: RESPONDING TO AN INCIDENT THAT YODOCK BARRIERS WITH CHAIN LINK FENCE ON TOP COLLAPSE AT EXPOSURE #2 ON TO THE STREET, INVESTIGATION REVEAL THAT YODOCK BARRIERS WERE NOT FULL AND CHAIN LINK FENCE WERE MISSING CL | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)