| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual boiler inspection (7 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-02-07 (Accepted). Agency page | Dec 31, 2026 in 44 days | 7 of 7 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 50,478 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 165 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 165 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 387). Agency page | Dec 31, 2027 in 409 days | Next due 2027 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 775 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 8, 2026 | Construction CLASS - 2 OBSERVED THROUGHOUT THE BUILDING NO TRAP WRAP INSULATION FOR TRAPS IN BATHROOMS. FOURTH FLOOR TWO SHOWERS NOT OPERATIONAL. BASEMENT SPRINKLER HEADS OBSTRUCTED. GAS DRYER LACKS A DEDICATED APPLIANCE SHUTOFF VALU #39173027Z | Feb 6, 2026 POP/IN-VIO | $0 |
| Apr 24, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN, AT TIME OF INSPECTION, I OBSERVED FIRE PUMP IN FUEL TANK ROOM, PROHIBITED BY NYC BC 913.2.1 SECTION 3., REPAIR AND/OR REPLACE #39146002Z | May 8, 2025 POP/IN-VIO | $0 |
| Dec 7, 2023 | Unknown CLASS - 2 I OBSERVED ON THE ROOFTOP THE RACEWAY AND JUNCTION BOXES SUPPLYING POWER TO VARIOUS EXHAUST FANS UNSUPPORTED AND LAYING ALONG THE ROOF AREA., SECURE/SUPPORT PER EC #39100935R | Jan 2, 2024 POP/IN-VIO | $0 |
| Dec 7, 2023 | Unknown CLASS - 2 I OBSERVED ON THE ROOF TOP LEVEL, A BX CABLE EXTENDED FROM THE WALL ABOVE THE EXIT DOOR NOT TERMINATED AS REQUIRED. ALL WIRING SHALL BE TERMINATED IN AN ACCEPTABLE JUNCTION BOX., COMPLY WITH EC #39100936Z | Jan 2, 2024 POP/IN-VIO | $0 |
| Dec 7, 2023 | Construction CLASS - 2 OBSERVED IN THE BASEMENT/CELLAR INADEQUATE VENTILATION IN THE GAS METER ROOM., REPAIR AND/OR REPLACE #39100961K | Jan 4, 2024 POP/IN-VIO | $0 |
| Dec 5, 2022 | Construction CLASS - 2 GAS METER ROOM NOT PROPERLY VENTED, AS PER APPENDIX E OF THE 2014 FGC AN OPENING TO THE OUTSIDE AIR IN THE WALL OF SUCH ROOM OR SPACE, PROVIDED THE FREE AREA OF THE OPENING IS NOT LESS THAN 30 SQUARE INCHES., R #39075078J | Dec 6, 2022 POP/IN-VIO | $0 |
| Dec 5, 2022 | Construction CLASS - 2 OBSERVED: AT ROOF LEVEL, WATERPROOFING MEMBRANE SHOWS DETACHMENT/HOLES AND OTHER FAILURES THAT ALLOW WATER PENETRATION INTO THE BUILDING., REPAIR AND/OR REPLACE #39075071R | Dec 6, 2022 POP/IN-VIO | $0 |
| Dec 5, 2022 | Construction CLASS - 2 OBSERVED: AT EXPOSURE # 2 & 3 FACADE, SEVERAL CRACKS IN DIFFERENT LOCATIONS. PREVIOUS VIOLATION # 39063664Y, MAINTAIN EXTERIOR BUILDING WALL #39075072Z | Dec 6, 2022 POP/IN-VIO | $0 |
| Dec 5, 2022 | Construction CLASS - 2 OBSERVED: AT ROOF LEVEL,BUCKHEAD, CEILING DAMAGES DUE WATER PENETRATION, ALSO, LOSS OF CORNERS OF THE EXTERIOR METAL COVERING (EXTERIOR SIDE) PREVIOUS VIOLATION # 39063665X., MAINTAIN EXTERIOR BUILDING WALL #39075073K | Dec 6, 2022 POP/IN-VIO | $0 |
| Jun 30, 2022 | Construction CLASS - 2 NO VENTILATION IN THE GAS METER ROOM. AS PER FGC GAS METER ROOMS SHALL BE PROPERLY VENTILATED., REPAIR AND/OR REPLACE #39065074N | Jul 8, 2022 PENDING | $1,562 |
| Jun 7, 2022 | Construction CLASS - 2 CRACKS IN FACADE ON EXP1(HAS SHED), EXP2, EXP3 REAR., MAINTAIN EXTERIOR BUILDING WALL #39063664Y | Jun 8, 2022 POP/IN-VIO | $0 |
| Jun 7, 2022 | Construction CLASS - 2 BULKHEAD AT ROOF LEVEL, PLASTER FALLING WATER IS COMING IN FROM ROOF. TEMPORARY BLUE NYLON TARP PLACE OVER FULL ROOF BEING HELD DOWN BY SAND BAGS THAT ARE ALL BROKEN NOW, TARP HAS BEEN RIPPED APART AND IS MOSTL #39063665X | Jun 8, 2022 POP/IN-VIO | $0 |
| May 31, 2022 | Unknown CLASS - 2 UNSAFE UNSUITABLE ELECTRICAL WIRING,EQUIPMENT IN USE.I OBSERVED AT THEROOF LEVEL OVER THE EXIT DOORS,ARMORED CABLE THATS POKING OUT AND SUBJECT TO ALL WEATHER ELEMENTS.ARMORED CABLE IS NOT INTENDED TO BE EXPOSE #35636546N | Sep 1, 2022 POP/IN-VIO | $0 |
| Sep 21, 2021 | Construction CLASS - 2 CRACKS IN FACADE ON EXP1(HAS SHED), EXP2, EXP3 REAR., MAINTAIN EXTERIOR BUILDING WALL #39047880Z | Oct 15, 2021 POP/IN-VIO | $0 |
| Sep 21, 2021 | Construction CLASS - 2 BULKHEAD AT ROOF LEVEL, PLASTER FALLING WATER IS COMING IN FROM ROOF. TEMPORARY BLUE NYLON TARP PLACE OVER FULL ROOF BEING HELD DOWN BY SAND BAGS THAT ARE ALL BROKEN NOW, TARP HAS BEEN RIPPED APART AND IS MOSTL #39047879L | Oct 15, 2021 POP/IN-VIO | $0 |
| Jun 30, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NO NATURAL OR MECHANICAL VENTILATION IN GAS METER ROOM AT CELLAR. REMEDY: MAINTAIN BUILDING AS PER CODE #35557795Z | Oct 7, 2021 POP/IN-VIO | $0 |
| Apr 1, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER - NO NATURAL ON MECHANICAL EXHAUST IN PLACE AT CELLAR GAS METER ROOM #35553961R | Jun 24, 2021 POP/IN-VIO | $0 |
| Feb 19, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER NOTE FAILURE TO PROVIDE FRESH AIR TO GAS METER RM@CELLAR LEVEL.PROVIDE FRESH AIR VENTILATION. #35546161N | May 20, 2021 POP/IN-VIO | $0 |
| Dec 15, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.FAILURE TO PROVIDE FRESH AIR TO GAS METER ROOM AT CELLAR LEVEL.PROVIDE FRESH AIR VENTILATION. #35542862H | Mar 11, 2021 POP/IN-VIO | $0 |
| Sep 25, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE AT CELLAR LEVEL IN GAS METER ROOM NO NATURAL FRESH AIR VENTILATION PROVIDED. REMEDY: REPAIR AND OR REPLACE PROVIDE FRESH AIR VENTILATION #35502897L | Jan 28, 2021 POP/IN-VIO | $0 |
| Feb 21, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED:AT TIME OF INSPECTION I OBSERVED AT CELLAR LEVEL AT GAS METER ROOM NO NATURAL OR MECHANICAL VENTILATION NEED TO PROVIDE PROPER VENTILATION IN GAS MET #35476083X | May 7, 2020 POP/IN-VIO | $0 |
| Jan 9, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER - NOTED AT CELLAR GAS METER ROOM NO NATURAL OR MECHANICAL VENTILATION. REMEDY: REPAIR/REPLACE #35467656J | Mar 26, 2020 POP/IN-VIO | $0 |
| Nov 23, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT CELLAR GAS METER ROOTS NOT NATURAL OR MECHANICAL VENTALATION.REM:COMPLY WITH CODE. #35461486Z | Feb 13, 2020 POP/IN-VIO | $0 |
| Oct 9, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE AT CELLAR LEVEL AT GAS METER ROOM NO VENTILATION FOR FRESH AIR AS PER CODE.REMEDYREPAIR AND/OR REPLACE(SUPPLY FRESH AIR VENTILATION). #35452412L | Dec 26, 2019 POP/IN-VIO | $0 |
| Sep 20, 2019 | Unknown CLASS - 2 I OBSERVED ON THE ROOFTOP UNSUPPORTED METAL RACEWAYS BOTH RIGID TYPE( INTERMEDIATE CONDUIT) AND FLEXIBLE TYPE(SEALTITE), COMPLY WITH EC #39009905Z | Oct 4, 2019 POP/IN-VIO | $0 |
| Sep 20, 2019 | Construction CLASS - 2 NOTED: OBSERVED AT EXPOSURE #1, HORIZONTAL CRACKS ALONG THE LENGTH OF THE RAMP, VERTICAL CRACKS AT EXPOSURE #2 FROM GRADE LEVEL UP TO THE SECOND STORY, VERTICAL CRACKS AT REAR EXPOSURE #3 NEXT TO ROOF'S DRAIN #39009830N | Oct 4, 2019 POP/IN-VIO | $0 |
| Sep 20, 2019 | Construction CLASS - 2 NO VENTILATION IN THE GAS METER ROOM. , REPAIR AND/OR REPLACE #39009835M | Oct 4, 2019 POP/IN-VIO | $0 |
| Jul 31, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED: AT CELLARGAS MOTOR ROOM HAS NO NATURAL OR MECHANICAL VENTILATION AS PER GAS FULL CODE APPENDIX E4. #35442483J | Oct 17, 2019 POP/IN-VIO | $0 |
| Jun 8, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE: AT BASEMENT LEVEL GAS METER ROOM NO FRESH AIR VENTILATION. OBSERVED. REMEDY: REPAIR AND REPLACE. #35434282N | Aug 15, 2019 POP/IN-VIO | $0 |
| May 18, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT TIME OF INSPECTION NOTED AT CELLAR GAS METER ROOM NO VENTIATION PROVIDED. RMDY: REPAIR/REPLACE. #35414912K | Jul 18, 2019 POP/IN-VIO | $0 |
| Apr 15, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: OBSERVED THROUGHOUT EXPOSURE #1 T VARIOUS LOCATIONS-CRACKS THROUGH BRICKS, BROKEN STONE NEAR ENTRANCE, CRACKS ALONG THE SIDE OF RAMP, CRACKED AND SP #35293804P | Apr 22, 2019 POP/IN-VIO | $0 |
| Apr 15, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVED SPALLLING PLASTER AT STAIR "A" BULKHEAD SOME PLASTER HAVE FALLEN ONTO THE LANDING, SPALLING PLASTER WITHIN SHOWER ROOMS ACROSS FROM UNIT 4- #35293805R | Apr 22, 2019 POP/IN-VIO | $0 |
| Apr 5, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED ON 4/5/19 AT ABOVE ADDRESS NO VENTILATION IN GAS METER ROOM LOCATED IN THE BASEMENT/CELLAR. REMEDY: REPAIR AND OR REPLACE #35415305N | Jun 13, 2019 POP/IN-VIO | $0 |
| Mar 23, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANER AT TIME OF INSPECTIONNOTED AT CELLAR GAS METER ROOM HAS NO VENTALATION FOR FRESH AIR.REM:COMPLY WITH CODE #35386112R | May 16, 2019 POP/IN-VIO | $0 |
| Jan 14, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION,I OBSERVED AT CELLAR LEVEL AT GAS METER ROOM HAS NO FRESH AIR VENTILATION NEED TO COMPLY W/SUMMONS & PROVIDE FRESH AIR VENTS. #35379854K | Mar 7, 2019 POP/IN-VIO | $0 |
| Dec 18, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION NOTED: CELLAR GAS METER ROOM DOES NOT HAVE NATURAL AND/OR MECHANICAL VENTILATION. REMEDY: COMPLY WITH CODE #35636127Z | Apr 14, 2022 POP/IN-VIO | $0 |
| Dec 3, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED: CELLAR LEVEL,GAS METER ROOM HAS NO FRESH AIR VENT. REMEDY: COMPLY WITH SUMMONS PROVIDE FRESH AIR VENTS. #35372689Y | Feb 14, 2019 POP/IN-VIO | $0 |
| Sep 27, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED ON 9/27/18 AT ABOVE ADDRESS NO FRESH AIR VENT IN GAS METER ROOM LOCATED IN THE BASEMENT. REMEDY: REPAIR AND OR REPLACE #35361832Y | Nov 29, 2018 POP/IN-VIO | $0 |
| Sep 27, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED:AT EXP#3 THERE ARE SEVERAL VERTICAL CRACKS AT BUILDING WALL. CRACKS ARE FROM CELLAR UP TO 2ND STORY IN VARIOUS LOCATIONS. RMDY: MAINTAIN EXTERIOR #35361388R | Nov 29, 2018 POP/IN-VIO | $0 |
| Mar 8, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.OBSERVED IN CELLAR NO VENTILATION IN THE GAS METER ROOM AS IS REQUIRED SEE:FGV (APPROX) (&) SECTION 4.REM:REPAIR &/OR REPLACE.PHOTOS TAKEN. #35325201J | May 17, 2018 POP/IN-VIO | $0 |
| Sep 22, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.DEFECT NOTED:PREMISES EXTERIOR BRICK WALL AT EXP3 (REAR) HAS APPROX 2"WIDE VERTICAL/STEP CRACKS AT VARIOUS LOCATION FROM CELLAR (GROUND) LEVEL TO 2ND FLOOR LVL #35207843Y | Nov 17, 2016 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
None open.