Bronx · Block 3314 · Lot 32 · 10468

2702 Creston Avenue

12 floors · 73 apartments · 63,406 sq ft · built 2023 · class D3 · owner of record: Spaxel Cbre Creston Llc

5open violations
$36,705ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 118 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 63,406 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029
Energy audit and retro-commissioning (2034) Likely applies
Local Law 87 · Calendar year 2034
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3314). Agency page

Dec 31, 2034
in 2988 days
Next due 2034

Open violations

ECB / OATH (14) · $36,705 owed
IssuedViolationHearingBalance
Sep 24, 2026Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIP OR INSTALLATION ON-SITE PERMIT. AS NOTED:AT TIME OF INSPECTION CONSTRUCTION SITE OF A PROPOSED 12 STORY BUILDING WAS CLOSED. OBSERVED CONSTRUCTION PLYWOOD FENCE WAS IN PLACE BUT WIT
#35730812H
Dec 4, 2026
PENDING
$1,250
Aug 25, 2026Construction CLASS - 2
AT TIME OF INSPECTION 5:30 AM, OBSERVED DEFECTIVE LIGHTING AT SIDEWALK SHED EXPS.1 CREATING DARK CONDITION. HAZARDOUS TO TENANTS/PEDESTRIANS, RISK OF SLIP/TRIP/FALL AND CRIMINAL ACTIVITY. NO PREVENTIVE MEASURES
#39558312P
Oct 30, 2026
PENDING
$2,400
Jul 30, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION OF A 12-STORY NEW BUILDING, I OBSERVED SIDEWALK SHED IN PLACE EXPOSURE#1, I OBSERVED THE SIDEWALK SHED HAS NO BUILDING INFORMATION PANEL. THIS CREATE A HAZARDOUS SITUATION FOR FIRST RE
#39557271N
Nov 20, 2026
PENDING
$1,250
Feb 19, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION, I OBSERVED PLASTIC BARRIERS INSTALLED ON THE ROADWAY NOT IN ACCORDANCE WITH BC3301.1.3 MANUFACTURER SPECIFICATIONS. THE BARRIERS WERE NOT INTERLOCKING AND NOT FILLED WITH WATER OR SAN
#39550558Z
Nov 20, 2026
$1,250
Feb 19, 2026Plumbing CLASS - 1
AT TIME OF INSPECTION, I OBSERVED ACTIVE WORK IN PROGRESS AT A 12-STORY NEW BUILDING TOPPED OFF. I SEARCHED THE DOB SYSTEM AND DID NOT FIND AN ELECTRICAL PERMIT FOR THE STANDPIPE ALARM SYSTEM. FAILURE TO PROVID
#39550560H
Nov 20, 2026
$5,000
Feb 19, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION, I OBSERVED SIDEWALK SHED NOT INSTALLED IN ACCORDANCE WITH BC 3307.1. ROTTEN MUD SILLS CREATED UNSTABLE SUPPORT POSTS. UNCAPPED BOLTS WITH EXPOSED SHARP EDGES WERE OBSERVED, CREATING A
#39550559K
Nov 20, 2026
PENDING
$2,400
Sep 25, 2025Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED NEEDLE BEAMS INSTALLED AT EXP. 2 OVER ADJ. PROPERTY. UPON REVIEWING DRAWINGS NOTICE IT DOES NOT CONFORM. DRAWINGS SHOWS 4 SETS OF DOUBLE NEEDLE BEAMS ONLY 3 ARE INSTALLED. DRAWING
#39545338K
Jan 8, 2027
$2,500
Aug 29, 2025Construction CLASS - 2
12-STORY NEW BUILDING RESPONDING TO AN INCIDENT WHERE A WORKER GOT HURT WORKING IN ELEVATOR SHAFT PIT AT FIRST FLOOR LEVEL, DURING MY INSPECTION UPON REQUESTING COMPETENT PERSON ONSITE FOR ORIENTATION FOR WORKE
#39544273Y
Apr 10, 2026
IN VIOLATION
$5,000
Feb 27, 2025Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE. AT EXP. 3 OBSERVED SEVERAL WORKERS AND MATERIALS SPREAD ON ENTIRE YARD NO EGRESS PATH. AT 8 FLOOR OBSERVED MATERIAL AND DEBRIS ALSO BLOCKING EGRESS PATH. ALSO DURI
#39537438H
May 14, 2027
PENDING
$1,280
Feb 27, 2025Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION SITE. NOTICE A WELDER CONDUCTING HOT WORK OPERATION. UPON REQUESTING HOT WORK PERMIT IT WAS NOT PROVIDED. AS PER FIRE CODE 3503.3 HOT WORK PERMIT IS REQUIRE. U
#39537437X
Oct 9, 2026
IN VIOLATION
$1,250
Feb 27, 2025Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION ACTIVITIES. AT 9TH FLOOR OBSERVED UNENCLOSED PERIMETER WITH INADEQUATE GUARDRAIL SYSTEM THE ZERO CABLE IS APPROX. 6" FROM DECK. ALL CABLES HAVE ONLY ONE CLAMP
#39537441Z
Sep 11, 2026
IN VIOLATION
$5,000
Feb 27, 2025Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED ACTIVE CRANE OPERATION NOT CONFORMING TO DRAWINGS. AS PER DRAWINGS IT SHOWS CRANE FULLY SURROUNDED BY BARRICADES NOT INSTALLED. PEDESTRIANS PASSING CLOSE TO CRANE. NO FLAGMAN DURI
#39537423P
Oct 9, 2026
IN VIOLATION
$2,500
Feb 27, 2025Unknown CLASS - 2
AT TIME OF INSPECTION OBSERVED ACTIVE HOT WORK OPERATIONS. WELDER WAS WORKING BY HIMSELF NO ONE ELSE PRESENT ON THIS FLOOR. UPON INQUIRED ABOUT FIRE GUARD WELDER SAID WAS NOT PRESENT. CONDITION CONTRARY TO BUIL
#39537442K
Oct 9, 2026
IN VIOLATION
$2,500
Jan 3, 2025Construction CLASS - 2
OBSERVED SUPPORTED PIPE SCAFFOLD IN INSTALLATION PROCESS @ EXPO 1 APPROX. 70FT. UPON REVIEW OF PROVIDED APPROVED PLANS IT STATES ONLY 1 FULLY DECK PLATFORM TO BE PROVIDED. HOWEVER, THERE ARE CURRENTLY 7 FULLY P
#39535633Y
Sep 1, 2026
DEFAULT
$3,125
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 24, 2026ECBConstruction: TEMPORARY CONSTRUCTION EQUIP OR INSTALLATION ON-SITE PERMIT. AS NOTED:AT TIME OF INSPECTION CONSTRUCTION SITE OF A PROPOSED 12 STORY BUILDING WAS CLOSED. OBSERVED CONSTRUCTION PLYWOOD FENCE WAS IN PLACE BUT WITOpen
Aug 25, 2026ECBConstruction: AT TIME OF INSPECTION 5:30 AM, OBSERVED DEFECTIVE LIGHTING AT SIDEWALK SHED EXPS.1 CREATING DARK CONDITION. HAZARDOUS TO TENANTS/PEDESTRIANS, RISK OF SLIP/TRIP/FALL AND CRIMINAL ACTIVITY. NO PREVENTIVE MEASURESOpen
Jul 30, 2026ECBConstruction: AT THE TIME OF INSPECTION OF A 12-STORY NEW BUILDING, I OBSERVED SIDEWALK SHED IN PLACE EXPOSURE#1, I OBSERVED THE SIDEWALK SHED HAS NO BUILDING INFORMATION PANEL. THIS CREATE A HAZARDOUS SITUATION FOR FIRST REOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)