5 floors · 10 apartments · 10,675 sq ft · built 1931 · class C6 · owner of record: 270 East 162 Street H
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 44 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-01 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 15, 2025 | B | Apt 6 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE FIRE ESCAPE WINDOW FRAME IN THE 1st ROOM FROM EAST LOCATED AT APT 6, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 20, 2025 |
| Sep 15, 2025 | B | Apt 6 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB [LOWER FAUCET] IN THE BATHROOM LOCATED AT APT 6, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 20, 2025 |
| Jan 31, 2025 | C | Apt 7 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 14, 2025 |
| Jan 31, 2025 | C | Apt 7 · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE DRAIN PIPE UNDER SINK IN THE KITCHEN LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2025 |
| Jan 31, 2025 | B | Apt 7 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL. IN THE BATHROOM LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Mar 7, 2025 |
| Jan 31, 2025 | B | Apt 7 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRRAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Mar 7, 2025 |
| Jan 31, 2025 | B | Apt 7 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH AND SOUTH WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Mar 7, 2025 |
| Jan 31, 2025 | C | Apt 7 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2025 |
| Jan 31, 2025 | C | Apt 7 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER TEMPERATURE EXCEEDING OVER 130 DEGREES AT BATHTUB AND WASH/BASIN IN THE BATHROOM LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2025 |
| Sep 21, 2020 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT LOBBY, 1st STORY | Dec 25, 2020 |
| Feb 24, 2020 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 16, 2020 |
| Sep 26, 2013 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING A MINIMUM OF 200 WATTS INCANDESCENT LIGHT REQUIRED. LIGHT FIXTURE PRESENT. | Oct 31, 2013 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 6:54 AM ET. BBL 2024210013.