Bronx · Block 3248 · Lot 49 · 10468

2685 University Avenue

6 floors · 180 apartments · 200,000 sq ft · built 1926 · class D7 · owner of record: Ardowork Corporation

156open violations
$69,990ECB/OATH penalties owed
34HPD class C (immediately hazardous)
46dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 46 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 46 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 62 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 200,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 167 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 167 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 290 days
Registered through 2027-09-01
Energy audit and retro-commissioning (2028) Likely applies
Local Law 87 · Calendar year 2028
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3248). Agency page

Dec 31, 2028
in 777 days
Next due 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-30 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (20) · $69,990 owed
IssuedViolationHearingBalance
Jul 29, 2026Unknown CLASS - 2
EXPIRED SIDEWALK SHED PERMIT. NOTED AT THE TIME OF INSPECTION I OBSERVED THAT PERMIT FOR SIDEWALK SHED HAD EXPIRED. I CHECKED ON THE SITE AND FOUND THAT NO PERMIT WAS DISPLAYED AT PREMISES. I THEN CHECH THE BIS
#35729923M
Oct 2, 2026
DEFAULT
$1,280
Jul 29, 2026Construction CLASS - 2
PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTED AT THE TIME OF INSPECTION I OBSERVED DEFECTIVE/INADEQUATE SHED CONDITIONS I. E. DAMAGED/ROTTED MUDSILLS ON MULTIPLE LOCATIONS WHICH IS NOT IN COMPL
#35729924Y
Oct 2, 2026
DEFAULT
$2,430
Jul 24, 2026Elevators CLASS - 1
RTS CLASS 1: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND OUT OF SERVICE, CREATING AN HAZARDOUS CONDITION FOR
#39198669L
Oct 16, 2026
DEFAULT
$1,280
May 20, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED ERECTED EXP#1-2-4 NOT COMPLYING TO CODE, ROTTER MUDSILLS UNSTABLE STANDING, SHARP EDGES CREATING CUTTING HAZARDS AND OPENING GAPS NOT PROTECTED FOR FALLING
#39554332Y
Jul 31, 2026
DEFAULT
$10,000
Mar 31, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED ERECTED AROUND A 6-STORY OCCUPIED BUILDING. REVIEW OF DOB NOW AND BIS RECORDS INDICATES SIDEWALK SHED PERMIT #X00830078-I1-SH EXPIRED ON 03/04/2026 AND HAS
#39552442X
Jun 5, 2026
DEFAULT
$6,250
Jan 21, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AS NOTED: AT TIME OF INSPECTION OBSERVED RETAINING WALL(RW) ALONG EXPOSURE #3, #2(NORTH AND WEST ELEVATION). THE RW WAS OBSERVED AND MEASURED TO 10 FEET HE
#35718088Y
Apr 17, 2026
DEFAULT
$12,500
Oct 2, 2025Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:AT EXP 2(S.ELEV)FIRE ESCAPE LADDER IS BLOCKED BY STORE FRONT SIGN LEADING TO WEST KINGSBRIDGE ROAD.REM:REMOVE OBSTRUCTION.
#35717709N
Apr 19, 2027
PENDING
$1,250
Oct 2, 2025Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTED:OBSERVED AT EXP 1(E.ELEV)DETERIORATED DECORATIVE STONE DETERIORATED BALCONY SLABS,AND CRACKED MASONRY AT MULTIPLE AT EXP.2(S.ELEV)BROKEN WIND
#35717710K
Apr 19, 2027
PENDING
$5,000
May 13, 2025Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE:-AT THE TIME OF INSPECTION OBSERVED, FIRE ESCAPE EGRESS ARE BLOCKING BY PLANT POT, BUCKET, ETC. AT MULTIPLE LOCATIONS OF FIRE ESCAPE LANDING AT EXPO #4 NORT
#35717050Y
Oct 31, 2025
IN VIOLATION
$1,250
Mar 8, 2025Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAYS. NOTE: AT TIME OF INSPECTION, I OBSERVED OBJECTS ON FIRE ESCAPES AT EXP #2 SOUTH, #3 WEST.-EXP #2 SOUTH, #3 WEST.-EXP #2 SOUTH HAS A LARGE AC UNIT BLOCKING FE PA
#35716759R
Feb 5, 2026
IN VIOLATION
$1,250
Apr 11, 2024Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7B, 8B, AND 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #915004. REMEDY: SUBMIT ACC
#37027965R
Aug 10, 2026
IN VIOLATION
$1,250
Dec 19, 2023Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR COMPLIANT, UPON INSPECTION, CLASS 1 RECURRING NO DLM. DOOR LACK MONITORING SYSTEM INSTALLED IN CONTROLLER, REMEDY; FILE APPLICATION THEN INSTALL DLM THEN FILE TEST WITH THE NYCDOB,
#39101810H
Aug 2, 2027
DEFAULT
$12,500
Apr 12, 2023Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS & APPURTENANCES.AS NOTED:AT TIME OF INSPECTION OBSERVED ON EXP #1 #2 #4 SEVERAL CORRODED METAL LINTELS AT 7TH FL & SEVERAL OTHER FLS,CORROSION CAUSE LINTELS TO SAGG C
#35670649P
Oct 11, 2024
IN VIOLATION
$1,250
Feb 13, 2023Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE & APPURTENANCES.NOTE:AT TIME OF INSPECTION OBSERVED BROKEN GLASS WINDOWS AT EXP #1 & #3 AT DIFFERENT LOCATIONS, CRACKED BRICKS/MORTAR JOINTS AT DIFFERENT LOCATIONS
#35670289K
Sep 8, 2023
IN VIOLATION
$6,250
Dec 9, 2022Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING FACADE & APPURTENANCES.NOTE:AT TIME OF INSPECTION OBSERVED EXP #1 EAST ELEVATION & EXP #3 WEST ELEVATION BROKEN WINDOW GLASS AT SEVERAL LOCATION DAMAGE WINDOW SILLS.EXP #1 EAST ELEV
#35669559N
Jul 14, 2023
IN VIOLATION
$2,500
Nov 30, 2022Elevators CLASS - 1
NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED IN APPENDIX K OF THE 2014 BUILDING CODES; REMEDY INSTALL DLM . FILE AND PERFORM TEST WITH NYC DOB; EMERGENCY COMMUNICATION IN ELEVATOR NOT WORKING; RE
#39074807X
Apr 26, 2024
IN VIOLATION
$625
Jun 9, 2022Elevators CLASS - 2
PHONE NOT WORKING, PROVIDE KEYS FOR MOTOR ROOM
#39063816Y
Oct 24, 2023
IN VIOLATION
$625
Dec 6, 2021Elevators CLASS - 1
CLASS 1 VIOLATION ISSUED DLM NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. FILE APPLICATION INSTALL DLM AND PERFORM AND FILE TEST. CLASS 2 VIOLATI
#39052296X
Oct 24, 2023
IN VIOLATION
$1,250
Nov 6, 2021Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES AT TIMEOF INSPECTION OBSERVED AT EXPOSURE#1(UNIVERSITY AVE)DEGRADED MORTAR JOINT BRICK AND TERRA COTTA AT VARIOUS LOCATION.ALSO CRACK AT MULTIPLE L
#35635277J
Jul 22, 2022
IN VIOLATION
$1,250
Sep 10, 2019Elevators CLASS - 2
(70O2,56Y13,59B1,11B10)70O#CLEAN HOISTWAY PIT.56Y#SEAL HOIST MOTOR FROM LEAK,59B#REPLACE WITH PERMANENT MARK ON TAG,11B#NUMBER 2 FLOOR BUTTON MISSING FROM STATION PROVIDE AND INSTALL.
#38271538N
Oct 22, 2021
IN VIOLATION
$0
DOB (11)
IssuedViolationStatus
Jul 29, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED AT THE TIME OF INSPECTION, OBSERVED STEP CRACK, DAMAGED/LOOSE/OPEN MORTAR JOINTS, DAMAGED WIINDOW LINTELS, SPALLING STONE ON ALL EXPOSURE. STEP CRACK ON BRICK MASONRY AND MOVEMENT OF WALL OBSERVED AT EXPOSURE 2 REMEDY: REPAIR AND/OR REPA
#SR20801JR
DOB VIOLATION - ACTIVE
Jul 29, 2026CONSTRUCTION
EWO. OBSRVD CRACKD/DISPLACD/BULGING BRICKS MASONRY @ THE FACDE, LINTEL & WINDOWSILLS. REMDY:IMMEDLY RETAIN A NYS RDP TO DIRECT & SUPERVSE WRK IN CONNECTN W/ REMOVAL & STABILIZTNOF CRACKD/DISPLACD/BULGING BRICK MASONRY @ THE FACDE, LINTEL & WINDOWSILLS. RDP MUST BE ONSITE F/T WHIL -E WRK TKING PLACE
#SR20809JR
DOB VIOLATION - ACTIVE
Jul 29, 2026CONSTRUCTION
FTM. OBSRVD LOOSE BRICKS, LOOSE WINDOWSILL, CRACKING/BULGING SPANDREL WALLS OPEN MORTAR JOINTS, CRACKING/BULGING LINTEL BRICKS @ EXP2 S.ELEV OF MULTI LOCATNS. REMDY:IMMEDLY RETAIN ANYS RDP W/ QEWI CERTI W/ MASO NRY FACDE EXPERCE TO INSPCT/EVALUTEENTIRE MASONRY FACDE. PROVDE ADEQT SFTY MEAS & FILE UN
#SR20810JR
DOB VIOLATION - ACTIVE
Dec 11, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00417
DOB VIOLATION - ACTIVE
Aug 2, 2024FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00289
DOB VIOLATION - ACTIVE
May 2, 2024FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00565
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01198
DOB VIOLATION - ACTIVE
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#00937
DOB VIOLATION - ACTIVE
Feb 13, 2023CONSTRUCTION
EMERGENCY WORK ORDER DUE TO OBSERVING SERIOUS CONDITIONS AT ALL 4 EXPOSURES SUCH AS BROKEN GLASS,WINDOW PANELS AT SEVERAL LOCATIONS, CRACKED,DAMAGED,SPALLING MORTAR JOINTS,BRICK WORK,STONES AT DIFFERENT LOCATIONS AT ALL EXPOSURES. REMEDY: PROVIDE PUBLIC SAFETY MEASURES SUCH AS SIDEWALK SHED AT ALL 4
#LLFA001BA
DOB VIOLATION - ACTIVE
Mar 16, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00155
DOB VIOLATION - ACTIVE
Jan 2, 1992ELEVATOR

#1450C2
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (51)
IssuedViolationStatus
Oct 7, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 7, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Dec 11, 2024AEUHAZ FTC-AEU-HAZ
Active
Dec 2, 2024Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Aug 2, 2024Benchmarking - LL84 FTF-EN-BENCH
Active
May 2, 2024Benchmarking - LL84 FTF-EN-BENCH
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
Mar 16, 2022AEUHAZ FTC-AEU-HAZ
Active
HPD (76) · C 34 · B 20 · A 22
IssuedClassViolationCorrect by
Oct 7, 2026BApt 35D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THANT 10 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 35D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18996153 ISSUED 04-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE Nov 11, 2026
Sep 29, 2026CApt 30D · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 30D, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''D'', AT NORTHOct 5, 2026
Sep 29, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT 1ST FIRE DOOR FROM NORTH AT PUBLIC HALL, 3rd STORY, SECTION ''D''Oct 13, 2026
Aug 26, 2026BApt 40D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT NORTH WALL IN THE KITCHEN LOCATED AT APT 40D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18818290 ISSUED 27-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODESep 30, 2026
Jul 27, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT FIRST DOOR LEADING FROM PUBLUC HALL TO SOUTH YARD AT PUBLIC HALL, 1st STORY, SECTION ''B''Aug 10, 2026
Jul 27, 2026C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF OWNING IMPEEDING DROP LADDER FROM DECENDING AT 2ND FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL AT FIRE ESCAPEAug 2, 2026
Jul 27, 2026C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING , 1st STORYAug 2, 2026
Jul 27, 2026A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING., 1st STORYOct 30, 2026
Jul 27, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLY AT FIRST DOOR LEADING FROM PUBLUC HALL TO SOUTH YARD AT PUBLIC HALL, 1st STORY, SECTION ''B''Aug 31, 2026
Jun 22, 2026CApt 12A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES NO COOKING TO RANGE IN THE KITCHEN LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTHJun 28, 2026
Jun 22, 2026AApt 12A · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING KNOB ON DOOR IN THE BATHROOM LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTHSep 25, 2026
Jun 22, 2026BApt 12A · § 27-2005 HMC: REFIT WINDOW SASHES ON EAST WALL IN THE KITCHEN LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTHJul 27, 2026
Jun 22, 2026AApt 12A · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTHSep 25, 2026
Jun 22, 2026AApt 12A · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION STEAM RISER ON SOUTH WALL IN THE KITCHEN LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTHSep 25, 2026
Jun 22, 2026BApt 12A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WOOD BASE CABINET ON WEST WALL IN THE KITCHEN LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTHJul 27, 2026
Jun 22, 2026AApt 12A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILINGS AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTHSep 25, 2026
Jun 22, 2026BApt 12A · § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WASHBASIN IN THE BATHROOM LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTHJul 27, 2026
Jun 9, 2026BApt 35D · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 35D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTHJul 14, 2026
Jun 9, 2026CApt 40D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE ON THE LOWER WINDOW SASH AT 1ST FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 40D, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 15, 2026
Jun 9, 2026BApt 35D · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 35D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTHJul 14, 2026
Jun 9, 2026CApt 40D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE ON THE UPPER WINDOW SASH AT EAST IN THE BATHROOM LOCATED AT APT 40D, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 15, 2026
Jun 8, 2026A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALLSep 11, 2026
Jun 8, 2026CApt 65E · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES NO COOKING GAS AT RANGE IN THE KITCHEN LOCATED AT APT 65E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''E''Jun 14, 2026
Jun 8, 2026C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALLJun 14, 2026
Jun 8, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMASep 11, 2026
May 15, 2026AApt 40D · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT INSIDE UPPER NORTH WALL CABINET IN THE KITCHEN LOCATED AT APT 40D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''D''Aug 18, 2026
May 15, 2026BApt 40D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT UPPER WINDOW SASH IN THE BATHROOM LOCATED AT APT 40D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''D''Jun 19, 2026
May 15, 2026AApt 40D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE KITCHEN LOCATED AT APT 40D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''D''Aug 18, 2026
May 13, 2026CApt 40A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 40A, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 8, 2026
May 13, 2026CApt 40A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 40A, 4th STORY, 1st APARTMENT FROM WEST AT NORTHMay 19, 2026
May 12, 2026CApt 41A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 41A, 4th STORY, 1st APARTMENT FROM NORTH AT EASTMay 18, 2026
May 1, 2026BApt 40A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 40A, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 5, 2026
May 1, 2026BApt 40A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES TO RANGE IN THE KITCHEN LOCATED AT APT 40A, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 5, 2026
May 1, 2026CApt 40A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 4th ROOM FROM EAST LOCATED AT APT 40A, 4th STORY, 1st APARTMENT FROM WEST AT NORTHMay 7, 2026
Apr 30, 2026BApt 40A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL AND NORTH WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 40A, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 4, 2026
Apr 30, 2026AApt 40A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 40A, 4th STORY, 1st APARTMENT FROM WEST AT NORTHAug 3, 2026
Apr 30, 2026BApt 40A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE FOYER LOCATED AT APT 40A, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 4, 2026
Apr 30, 2026AApt 40A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 40A, 4th STORY, 1st APARTMENT FROM WEST AT NORTHAug 3, 2026
Apr 30, 2026BApt 40A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 40A, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 4, 2026
Apr 29, 2026AApt 40D · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION RISER IN THE BATHROOM LOCATED AT APT 40D, 4th STORY, 1st APARTMENT FROM WEST AT NORTHAug 2, 2026
Apr 28, 2026AApt 40D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR AND SUBFLOOR IN THE KITCHEN LOCATED AT APT 40D, 4th STORY, 1st APARTMENT FROM WEST AT NORTHAug 1, 2026
Apr 28, 2026AApt 40D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE KITCHEN LOCATED AT APT 40D, 4th STORY, 1st APARTMENT FROM WEST AT NORTHAug 1, 2026
Mar 30, 2026CApt 11E · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 11E, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''E''Apr 5, 2026
Feb 17, 2026CApt 44A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 44A, 4th STORY, 2nd APARTMENT FROM SOUTH AT WESTMar 15, 2026
Feb 17, 2026CApt 35D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 35D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTHMar 15, 2026
Feb 17, 2026CApt 35D · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 35D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTHFeb 23, 2026
Feb 12, 2026CApt 44A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 44A, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''North'', 1st FROM WEST AT NORTHFeb 18, 2026
Feb 12, 2026CApt 44A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HARD TO OPEN/STUCK (LOWER SASH) AT FIRE ESCAPE WINDOW IN THE 3rd ROOM FROM EAST LOCATED AT APT 44A, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''North'', 1st FROM WEST AT NORTHFeb 18, 2026
Jan 9, 2026CApt 10B · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 10B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 15, 2026
Dec 5, 2025CApt 11A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER AND LOWER SASH AT 2ND WINDOW FROM NORTH AT EAST IN THE 1st ROOM FROM NORTH LOCATED AT APT 11A, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTDec 11, 2025
Sep 3, 2025CApt 12A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 12A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHSep 9, 2025
Jul 25, 2025CApt 11A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 11A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''''A''''Jul 31, 2025
Jun 2, 2025CApt 23A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE ENTIRE APARTMENT LOCATED AT APT 23A, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTJun 8, 2025
May 22, 2025CApt 11A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 11A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''A''May 28, 2025
May 7, 2025CApt 11A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 11A, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTMay 13, 2025
May 1, 2025CApt 11A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 11A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''A''May 7, 2025
Apr 11, 2025BApt 11A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES STOVE IN THE KITCHEN LOCATED AT APT 11A, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTMay 16, 2025
Feb 6, 2025AApt 22C · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION STEAM RISER IN THE BATHROOM LOCATED AT APT 22C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''C''May 12, 2025
Feb 6, 2025BApt 22C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10SQ FT AT CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 22C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''C''Mar 13, 2025
Feb 6, 2025AApt 22C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN THE 4th ROOM FROM NORTH LOCATED AT APT 22C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''C''May 12, 2025

Showing 60 of 76. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Oct 7, 2026DOB SafetyAEUHAZ: Open
Oct 7, 2026DOB SafetyAEUHAZ: Open
Oct 7, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THANT 10 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 35D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18996153 ISSUED 04-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE Open
Sep 29, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 30D, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''D'', AT NORTHOpen
Sep 29, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT 1ST FIRE DOOR FROM NORTH AT PUBLIC HALL, 3rd STORY, SECTION ''D''Open
Sep 16, 2026DOB SafetyFacades: Unsafe 10B report filedClosed
Aug 26, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT NORTH WALL IN THE KITCHEN LOCATED AT APT 40D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18818290 ISSUED 27-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODEOpen
Jul 29, 2026DOBCONSTRUCTION: FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED AT THE TIME OF INSPECTION, OBSERVED STEP CRACK, DAMAGED/LOOSE/OPEN MORTAR JOINTS, DAMAGED WIINDOW LINTELS, SPALLING STONE ON ALL EXPOSURE. STEP CRACK ON BRICK MASONRY AND MOVEMENT OF WALL OBSERVED AT EXPOSURE 2 REMEDY: REPAIR AND/OR REPAOpen
Jul 29, 2026DOBCONSTRUCTION: EWO. OBSRVD CRACKD/DISPLACD/BULGING BRICKS MASONRY @ THE FACDE, LINTEL & WINDOWSILLS. REMDY:IMMEDLY RETAIN A NYS RDP TO DIRECT & SUPERVSE WRK IN CONNECTN W/ REMOVAL & STABILIZTNOF CRACKD/DISPLACD/BULGING BRICK MASONRY @ THE FACDE, LINTEL & WINDOWSILLS. RDP MUST BE ONSITE F/T WHIL -E WRK TKING PLACE Open
Jul 29, 2026DOBCONSTRUCTION: FTM. OBSRVD LOOSE BRICKS, LOOSE WINDOWSILL, CRACKING/BULGING SPANDREL WALLS OPEN MORTAR JOINTS, CRACKING/BULGING LINTEL BRICKS @ EXP2 S.ELEV OF MULTI LOCATNS. REMDY:IMMEDLY RETAIN ANYS RDP W/ QEWI CERTI W/ MASO NRY FACDE EXPERCE TO INSPCT/EVALUTEENTIRE MASONRY FACDE. PROVDE ADEQT SFTY MEAS & FILE UNOpen
Jul 29, 2026ECBUnknown: EXPIRED SIDEWALK SHED PERMIT. NOTED AT THE TIME OF INSPECTION I OBSERVED THAT PERMIT FOR SIDEWALK SHED HAD EXPIRED. I CHECKED ON THE SITE AND FOUND THAT NO PERMIT WAS DISPLAYED AT PREMISES. I THEN CHECH THE BISOpen
Jul 29, 2026ECBConstruction: PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTED AT THE TIME OF INSPECTION I OBSERVED DEFECTIVE/INADEQUATE SHED CONDITIONS I. E. DAMAGED/ROTTED MUDSILLS ON MULTIPLE LOCATIONS WHICH IS NOT IN COMPLOpen
Jul 27, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT FIRST DOOR LEADING FROM PUBLUC HALL TO SOUTH YARD AT PUBLIC HALL, 1st STORY, SECTION ''B''Open
Jul 27, 2026HPD C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF OWNING IMPEEDING DROP LADDER FROM DECENDING AT 2ND FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL AT FIRE ESCAPEOpen
Jul 27, 2026HPD C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING , 1st STORYOpen
Jul 27, 2026HPD A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING., 1st STORYOpen
Jul 27, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLY AT FIRST DOOR LEADING FROM PUBLUC HALL TO SOUTH YARD AT PUBLIC HALL, 1st STORY, SECTION ''B''Open
Jul 24, 2026ECBElevators: RTS CLASS 1: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND OUT OF SERVICE, CREATING AN HAZARDOUS CONDITION FOROpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 2:56 AM ET. BBL 2032480049.

Look up another building