Staten Island · Block 752 · Lot 7501 · 10314

267 Gower Street

1 floors · 8,335 sq ft · built 1950 · class R5 · owner of record: Gower Llc,

0open violations
$19,375ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1143dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029

Open violations

ECB / OATH (4) · $19,375 owed
IssuedViolationHearingBalance
Aug 1, 2024Construction CLASS - 1
FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE REMOVED CREATING AN UNSAFE CONSTRUCTION SITE ACCESSIBLE TO THE PUBLIC. NOTED
#39120623X
Feb 8, 2027
$12,500
Aug 29, 2023Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED 4 WORKERS FRAMING EXTERIOR WALLS. I ASKED COMP PERON TO PRODUCE ALL REQUIRED DOCUMENTATION FOR THE DAYS ACTIVITIES. NONE WAS PROVIDED,. MISSING DAILY LOG BOOK ENTRY,PRE - SHIFT ME
#39521151Y
Mar 4, 2025
IN VIOLATION
$1,250
May 22, 2023Construction CLASS - 1
MISSING GUARDRAIL SYSTEM. OBSERVED MISSING GUARDRAIL SYSTEM AROUND PERIMETER OF FOUNDATION WALL AT EXP#1, EXP#2 FRONT, AND EXP#4 FRONT. EXCAVATION IS APPROX. 10 FEET IN DEPTH WITH LOWEST POINT AT APPROX. 15 FEE
#39516921P
Jul 8, 2025
IN VIOLATION
$625
May 22, 2023Unknown CLASS - 1
AT TIME OF INSPECTION ACTIVE JOBSITE. UPON REQUEST FOR COMPETENT PERSON OR CONSTRUCTION SUPERINTENDENT, WORKERS STATED THEY ARE NOT ON SITE. UPON REVIEW OF SUPERINTENDENT LOGS IT WAS OBSERVED THAT SUPERINTENDEN
#39516923Z
Jul 8, 2025
IN VIOLATION
$5,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 9:10 AM ET. BBL 5007527501.

Look up another building