Brooklyn · Block 2264 · Lot 5 · 11206

265 Lee Avenue

4 floors · 6 apartments · 7,880 sq ft · built 1931 · class C6 · owner of record: S&K Residence Llc

56open violations
$5,000ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 67 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 83 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 798 days
Next cycle year 2028

Open violations

ECB / OATH (2) · $5,000 owed
IssuedViolationHearingBalance
Mar 14, 2019Construction CLASS - 1
TAMPERED W/REMOVED OR DEFACED A WRITTEN POSTED STOP WORK ORDER. NOTED:AT TIME OF REINSPECTION,WHERE A WRITTEN & POSTED SWO W/VIOLATIONS POSTED AT GATE FOUND DOCUMENT & VIOLATION REMOVED FROM GATE UPON REINSPECT
#35407707X
Nov 19, 2019
IN VIOLATION
$2,500
Mar 14, 2019Construction CLASS - 1
WORK W/O A PERMIT. NOTED: AT TIME OF INSPECTION FOUND AT REAR OF PREMISES,ERECTED STEEL STRUCTURE CONSISTING OF 4X4 STEEL POST X6 W/NEWLY POURED CONCRETE FOOTINGS BOLTED TO SLAB,W/STEEL I-BEAMS HORIZONTALLY INS
#35407702R
Nov 18, 2019
IN VIOLATION
$2,500
DOB (2)
IssuedViolationStatus
Mar 14, 2019CONSTRUCTION
4 STORY BUILDING WITH 4 APARTMENTS. 1 APT. ON 2ND FLOOR. 1 APT. ON 3RD FLOOR AND 2 APTS ON 4TH FLOOR HAVE BEEN ALTERED AND THE FIRE ESCAPE HAS BEEN REMOVED FOR THE RESIDENTS ON ALL LEVELS
#CER01RJ
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#24146
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (54) · C 2 · B 38 · A 14
IssuedClassViolationCorrect by
May 27, 2008BD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES WALLS & CEILING 2 STYPUBLIC HALL.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE PLUMBING MATERIAL & JUNK CELLAR THRU OUT.Jul 1, 2008
May 27, 2008AD26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLE CHAIRS & HOUSEHOLD ARTICLES AT SCUTTLE LADDER 4 STY PUBLIC HALL.Aug 30, 2008
May 27, 2008ASECTION 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER FRONT FIRE ESCAPE.Aug 30, 2008
May 27, 2008BD26-10.01 ADM CODE PROPERLY SECURE THE LOOSE CLG LIGHT FIXTURE 1 STY PUB HALL.Jul 1, 2008
May 27, 2008AD26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALL & CLGS ALL STYS PUB HALL.Aug 30, 2008
May 27, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC WALL TILES 1 STY PUB HALL.Jul 1, 2008
May 27, 2008ASECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING FRAME.Aug 30, 2008
May 27, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTERBOARD CLG CELLAR REAR.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CLG BOILER ROOM CELLAR.Jul 1, 2008
May 27, 2008BD26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS BOILER ROOM CELLAR.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE MISSING FLAP DOOR CELLAR REAR.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE MISSING SHINGLES ASPHALT EXTERIOR NORTH AND WEST WALLS ALL STYS.Jul 1, 2008
May 27, 2008CD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUB HALL.Jun 2, 2008
May 27, 2008AD26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING.Aug 30, 2008
May 27, 2008BApt 4 · D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE PUTTY WINDOW SASHES NORTH EAST ROOM 4 STY EAST APT 4. LOCATED AT APT 4Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS ALL STYS PUB HALL.Jul 1, 2008
May 27, 2008AD26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG VESTIBULE 1 STY PUB HALL.Aug 30, 2008
May 27, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SIDING 1 STY LEVEL NORTH EXTERIOR WALL.Jul 1, 2008
May 27, 2008AD26-12.03 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT FRONT FIRE ESCAPE ALL STYS.Aug 30, 2008
May 27, 2008BD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED WIRING CLG LIGHT 2 STY PUB HALL.Jul 1, 2008
May 27, 2008AD26-10.01 ADM CODE PROPERLY SECURE THE LOOSE CLG LIGHT FIXTURE 2ND STY PUB HALL.Aug 30, 2008
May 27, 2008AD26-10.01 ADM CODE REPLACE WITH NEW THE MISSING SIDING AT 2ND STY LEVEL WEST WALL OF BLDG.Aug 30, 2008
May 27, 2008ASECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD EXTENSION ERECTED ON ROOF OF GARAGE 2ND STY LEVEL BLDG REAR.Aug 30, 2008
May 27, 2008BSECTION 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION OPENING CREATED AT REAR OF 2ND STY NORTH APT TO 2ND STY SOUTH APT COMBINING 2 APTS INTO ONE.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC TILE VESTIBULE FLOOR 1 STY PUB HALL.Jul 1, 2008
May 27, 2008BD26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CELLAR THRU OUT.Jul 1, 2008
May 27, 2008AApt 4E · D26-10.01,20.07 ADM CODE PROVIDE APPROVED ONE-HOUR FIRE RESISTANCE RATED SELF-CLOSING DOOR WITH KEY-OPERATED DEAD BOLT & LATCH SET, PEEP HOLE & CHAIN GUARD AT MAIN ENTRANCE TO 4 STY EAST APT 4E. LOCATED AT APT 4EAug 30, 2008
May 27, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT PLASTER CEILING 1 STY VESTIBULE.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE CEILING 1 STY VESTIBULE PUBLIC HALL.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAILBOXES 1 STY PUBLIC HALL.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR 2 STY RIGHT APT FOYER & KITCHEN.Jul 1, 2008
May 27, 2008BD26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BUILDING MATERIALS ETC 4 STY PUBLIC HALL.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CEILING BOILER ENCLOSURE CELLAR AT CENTER.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILING CELLAR THRU OUT.Jul 1, 2008
May 27, 2008BD26-19.01 ADM CODE PROVIDE ADEQUATE LIGHTING CELLAR SOUTH & EAST.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH NORTH WINDOW 2 STY EAST APT KITCHEN.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE MISSING SASH CHAINS ALL WINDOWS 2 STY EAST APT THRU OUT.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE MISSING PUTTY ALL WINDOWS 2 STY EAST APT THRU OUT.Jul 1, 2008
May 27, 2008AD26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILING 2 STY EAST APT SOUTHEAST ROOM.Aug 30, 2008
May 27, 2008BD26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS NORTH ENTRANCE 2 STY EAST APT.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS LOWER SASH EAST WINDOW 4 STY EAST APT NORTHWEST ROOM.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILING 4 STY EAST APT EAST ROOM.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE PROPERLY SECURE THE LOOSE ON & OFF SWITCH NORTH WALL 4 STY EAST APT EAST ROOM.Jul 1, 2008
May 27, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE MISSING SWITCH PLATE NORTH WALL & WEST WALL 4 STY EAST APT EAST ROOM & FOYER.Jul 1, 2008
May 27, 2008AD26-10.01,20.07 ADM CODE PROVIDE APPROVED ONE-HOUR FIRE RESISTANCE RATED SELF-CLOSING DOOR WITH KEY-OPERATED DEAD BOLT & LATCH SET, PEEP HOLE & CHAIN GUARD AT MAIN ENTRANCE TO 4 STY WEST APT.Aug 30, 2008
May 27, 2008BSECTION 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION 2 STY NORTH APT CONNECTED 2 STY SOUTH APT INCREASING ROOMS NORTH APT & DECREASING ROOMS SOUTH APT.Jul 1, 2008
May 27, 2008BD26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS 2 STY PUBLIC HALL.Jul 1, 2008
May 27, 2008BD26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION 3 STY PUBLIC HALL.Jul 1, 2008
May 27, 2008AApt 4L · D26-10.01,20.07 ADM CODE PROVIDE APPROVED ONE-HOUR FIRE RESISTANCE RATED SELF-CLOSING DOOR WITH KEY-OPERATED DEAD BOLT & LATCH SET, PEEP HOLE & CHAIN GUARD AT MAIN ENTRANCE TO 4 STY WEST APT 4L. LOCATED AT APT 4LAug 30, 2008
May 27, 2008BApt 4L · D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASHBASIN 4 STY WEST APT 4L BATHROOM. LOCATED AT APT 4LJul 1, 2008
May 27, 2008BApt 4L · D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE 4 STY WEST APT 4L PRIVATE HALL. LOCATED AT APT 4LJul 1, 2008
May 27, 2008CApt 2L · D26-17.07 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2 STY EAST APT 2L KITCHEN & BATHROOM ER1. LOCATED AT APT 2LJun 2, 2008
Nov 28, 2005BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS LIGHTS NOT ONJan 7, 2006

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)