3 floors · 67,742 sq ft · built 1916 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 67,742 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3168). Agency page | Dec 31, 2028 in 798 days | Next due 2028 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-17 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 11, 2026 | Construction CLASS - 2 REISSUE ON ECB#39175676H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:ILLEGAL OFF STREET PARKING WITH CURB CUT WITH 18 CARS IN SCHOOLYARD ON CORNER OF CRESTON AVENUE AND KINGSBRIDGE AND 2 CARS ON #35734269N | Jul 17, 2026 POP/IN-VIO | $0 |
| Jun 11, 2026 | Construction CLASS - 2 REISSUE ON ECB#35721400R FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FIRE RATED CLASSROOMS AND SMOKE DOORS NOT SELF-CLOSING DUE TO BINDING,MISSING AND OR FAULTY HARDWARE ON CLASSROOMS 302,301 2 #35734265X | Jul 17, 2026 POP/IN-VIO | $0 |
| Jun 11, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:EMERGENCY EXIT DISCHARGE EXIT SIGN BOXES AND EXIT SIGNS NOT ILLUMINATE #35734270K | Jul 17, 2026 POP/IN-VIO | $0 |
| Jun 11, 2026 | Construction CLASS - 2 REISSUE ON ECB#35721401Z FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT CELLAR LEVEL INSIDE ELECTRICAL SWITCH GEAR ROOM FOUNDATION WALL HAS WATER PENETRATION THROUGH POUROUS FOUNDATION WALL OBSE #35734264Y | Jul 17, 2026 POP/IN-VIO | $0 |
| Jun 11, 2026 | Construction CLASS - 2 REISSUE ON ECB#35721402K,35720974L FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT EXPOSURE#2 OUTSIDE STEPS METER LOADING OUTFROM BOILER ROOM TO STREET LEVEL IS RUSTED,CORRODED AND IN DISREPAIR O #35734267J | Jul 17, 2026 POP/IN-VIO | $0 |
| Jun 11, 2026 | Construction CLASS - 2 REISSUE ON ECB#35582341Z FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:DOUBLE DOOR SMOKE DOORS OPEN AGAINST THE FLOOR EGRESS EMERGENCY EXIT PASSAGE WHICH REQUIRE AN OUTWARD SWING ON 1ST FLOOR CORR #35734216J | Jul 10, 2026 POP/IN-VIO | $0 |
| Jun 11, 2026 | Construction CLASS - 2 REISSUE#35473210X EXIT DOOR NOT SELF CLOSING.NOTED:EMERGENCY EXIT EXTERIOR DOOR NOT SELF-CLOSING DUE TO BINDING MISSING AND OR FAULTY HARDWARE ON EXTERIOR 1ST FL AUDITORIUM EMERGENCY EXIT,EXTERIOR FIRE ESCAPE D #35734268L | Jul 17, 2026 POP/IN-VIO | $0 |
| Jun 11, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT BOILER ROOM IN VARIOUS CONDITIONS HAS EXPOSED PLASTER CEILING BLOWOUTS WITH CORRODED WIRE LATHE AND BLACK IRON THAT SUPPORTS PLASTER INCLUDING A CO #35734266H | Jul 17, 2026 POP/IN-VIO | $0 |
| Feb 2, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLEGAL OFF-STREET PARKING W/ CURB CUT CREATED AND MAINTAINED WITHOUT DOB APPROVAL CONTRARY TO ZR 25-62, BC 3202.2.2.4 AND CITY RECORDS (COFO# 46670-71). O #39175676H | Feb 6, 2026 POP/IN-VIO | $0 |
| Jul 22, 2025 | Construction CLASS - 2 REISSUE: 35692305Z-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: 1ST FL. CORRIDOR DOORS NOT CLOSING PROPERLY. REMEDY: COMPLY WITH CODE. #35721400R | Aug 22, 2025 PENDING | $3,125 |
| Jul 22, 2025 | Construction CLASS - 2 REISSUE: 35692308Y-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. CELLAR LEVEL FOUNDATION WALLS HAVE BECOME POROUS ALLOWING WATER TOINFILTRATE INSIDE ELECTRICAL ROOM. REMEDY: COMPLY WITH CODE. #35721401Z | Aug 22, 2025 PENDING | $3,125 |
| Jul 22, 2025 | Construction CLASS - 2 REISSUE: 35676430H-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: METAL STAIRCASE BY GAS ROOM IS RUSTED, ALSO NOTED: BROKEN STEP LEADING TO BOILER ROOM. REMEDY: COMPLY WITH CODE. #35721402K | Aug 22, 2025 PENDING | $3,125 |
| Jul 22, 2025 | Construction CLASS - 2 REISSUE: 3569230X-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: OUTSIDE BOILER ROOM, ADJACENT TO GAS-METER HAS CORRODED METAL. REMEDY: COMPLY WITH CODE. #35720974L | Aug 22, 2025 PENDING | $3,125 |
| Oct 8, 2024 | Construction CLASS - 2 REISSUE#35676425N FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED INTERIOR FPSC DOORS NOT CLOSING PROPERLY 3RD FL RM 307,304,303CORRIDOR SMOKE DOORS BY ROOM 304 & 303,2ND FL RM 206 1ST FL CORRIDOR S #35692305Z | Dec 20, 2024 POP/IN-VIO | $0 |
| Oct 8, 2024 | Construction CLASS - 2 REISSUE#35676429K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT CELLAR LEVEL FOUNDATION WALLS HAVE BECOME POROUS ALLOWING WATER TO INFILTINATE INSIDE ELECTRICAL ROOM,BOILER ROOM & ALONG CRAWL S #35692308Y | Dec 20, 2024 POP/IN-VIO | $0 |
| Oct 8, 2024 | Construction CLASS - 2 REISSUE#35676430H FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED EXTERIOR STEPS OUTSIDE THE BOILER ROOM ADJACENT TO GAS METER HAVE CORRODED METAL.REM:REPAIR AND/OR REPLACE. #35692309X | Dec 20, 2024 POP/IN-VIO | $0 |
| Mar 23, 2024 | Unknown CLASS - 2 SCREWED IT TIGHT. ON THE OUTSIDE OF THE BUILDING ON 193 STREET, THERE IS ROMEX USED OUTSIDE, COMING OUT OF A LIGHT FIXTURE., COMPLY WITH EC; REMOVE THE ROMEX FROM OUTSIDE. #39109683K | May 29, 2024 POP/IN-VIO | $0 |
| Jul 20, 2023 | Construction CLASS - 2 REISSUE #35582340R NOTED: AT 3RD FLOOR CORRIDOR BY ROOM 303, CORRIDOR BY STAIR C, ROOM 307, 2ND FLOOR ROOM 206, 1ST FLOOR CORRIDOR BY ROOM 110, ROOM 108, AND BASEMENT LEVEL ROOM B3, THE DOORS ARE NOT WORKING PR #35676425N | Oct 20, 2023 POP/IN-VIO | $0 |
| Jul 20, 2023 | Construction CLASS - 2 REISSUE #35582341Z NOTED: THE CORRIDOR DOORS AT 1ST FLOOR LEVEL OPENS AGAINST EGRESS. REMEDY: REPAIR AND/OR REPLACE #35676349K | Oct 20, 2023 POP/IN-VIO | $0 |
| Jul 20, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED:AT CELLAR LEVEL , THE FOUNDATION WALL FROM THE ELECTRICAL ROOM TO THE VACCUM PUMP HAS BECOME POROUS AND IS ALLOWING WATER INTO THE BOILER ROOM. OBSER #35676429K | Oct 20, 2023 POP/IN-VIO | $0 |
| Jul 20, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED:AT CELLAR LEVEL THE STAIRS LEADING TO THE BOILER ROOM HAS A BROKEN STEP AT THE BOTTOM. ALSO, THE METAL STAIRCASE BY THE GAS METERS HAVE EXCESSIVE RUS #35676430H | Oct 20, 2023 POP/IN-VIO | $0 |
| May 18, 2023 | Construction CLASS - 3 WORK WITHOUT A PERMIT. INSTALLED AN ILLEGAL CURB CUT AT EXPOSURE#1, OBTAIN PERMIT OR RESTORE PREMISES TO PRIOR LEGAL CONDITION; OBTAIN PERMITS #39086630H | May 29, 2023 POP/IN-VIO | $0 |
| May 15, 2023 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THE DEPARTMENT OF AT TIME OF INSPECTION NOTICE VEHICLE PARKED ON SCHOOL GROUNDS. C OF O DOES NOT INDICATE ANY PARKING LOTS., DISCONTINUE ILLEGAL OCCUPANCY OR AMEND C OF O #39086641N | May 29, 2023 POP/IN-VIO | $0 |
| May 15, 2023 | Construction CLASS - 2 ILLEGAL PARKING, DISCONTINUE ILLEGAL OCCUPANCY OR AMEND C OF O; DISCONTINUE ILLEGAL USE #39086251H | May 29, 2023 POP/IN-VIO | $0 |
| Jul 26, 2021 | Construction CLASS - 2 REISSUE #35498124K DATE OF ISSUE:06-11-2020 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED 3RD FL CORRIDOR DOORS (STAIR-C) RM -3030 & NEAR STAIR B SMOKE DOORS ARE BUCKLING ON EACH OTHER ALSO FIRST #35582340R | Oct 29, 2021 POP/IN-VIO | $0 |
| Jul 26, 2021 | Construction CLASS - 2 REISSUE #35498123Z DAT EOF ISSUE:06-112020 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER 1ST FLOOR CORRIDOR DOUBLE DOOR.SMOKE DOROS OPEN AGAINST THE FLOOR AGAINST EGRESS REPAIR AND ORE PLACE REPAIR AND #35582341Z | Oct 29, 2021 POP/IN-VIO | $0 |
| Jun 11, 2020 | Construction CLASS - 2 REISSUE#352434079H FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: ON THE 1ST FL CORRIDOR DOORS OPENING AGAINST THE EGRESS. REMEDY: REPAIR &/OR REPLACE. #35498123Z | Oct 2, 2020 POP/IN-VIO | $0 |
| Jun 11, 2020 | Construction CLASS - 2 REISSUE#35434077Y FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: 3RD FL CORRIDOR DOORS ARE BUCKLING ON EACH OTHER,ALSO THE 1ST FLNORTH CORRIDOR DOORS ARE BUCKLING ON EACH OTHER. REMEDY: REPAIR &/OR #35498124K | Oct 2, 2020 POP/IN-VIO | $0 |
| Jun 1, 2020 | Construction CLASS - 2 RE-ISSUE #35434079H FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.NOTE:DURING INSPECTION OBSERVED AT 1ST FL CORRIDOR,DOUBLE(SMOKE) DOORSOPEN AGAINST THE FLOW OF EGRESS.REMEDY:REPAIR/REPLACE. #35473211H | Oct 2, 2020 POP/IN-VIO | $0 |
| Jun 1, 2020 | Construction CLASS - 2 RE-ISSUE #35434077Y FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.NOTE:DURING INSPECTION OBSERVED AT 3RD FL CORRIDOR-STAIR C,NEAR RM 303& NEAR STAIR B SMOKE DOORS ARE BUCKLING ON EACH OTHER ALSO AT 1ST FL #35473212J | Oct 2, 2020 POP/IN-VIO | $0 |
| Jun 1, 2020 | Construction CLASS - 2 RE-ISSUE #35434081R EXIT DOOR NOT SELF-CLOSING NOTE:DURING INSPECTION OBSERVED AT 3RD FLR-ST.C,3RD FLR-NEAR RM.303,3RD FLR-ST.B,2ND FLR-ST.B2ND FLR-ST.C,1ST FLR-ST A,1ST FLR-ST.B(BOTH DOORS MISSING) & AT CELLAR #35473210X | Oct 2, 2020 POP/IN-VIO | $0 |
| Jul 2, 2019 | Construction CLASS - 2 EXIT DOOR NOT SELF CLOSING PROPERLY AT FIRST FLOOR NEAR TO MAIN ENTRANCE ADUITORIUM MAIN ENTRANCE EXIT DOOR NOT SLE FLCOSING PROPERLY AT THE TIME OF INSPECTIONWHEN TESTED AT BASEMENT LEVEL EIXT #2 TWO DOORS ARE #35434081R | Sep 6, 2019 POP/IN-VIO | $0 |
| Jul 2, 2019 | Construction CLASS - 2 REISSUE #35334379L DATE OF ISSUE 05-18-2018 FAILURE TO MAINTIAN BUILDING IN CODE COMPLAINT AMNNER 1ST FLOOR FLR CORRIDOR DOUBLE DOOR/SMOKE DOORS OPEN AGAINST THE FLOR AGAINST EGRESS REPAIR AND/OR REPLACE/COPLWY #35434079H | Sep 6, 2019 POP/IN-VIO | $0 |
| Jul 2, 2019 | Construction CLASS - 2 REISSUE #35334380Z DATE OF ISSUE 05-18-2018 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER 3RD FOOR CORRIDOR SMOKE DOORS ARE BUCKLING ON EACH OTHER 1ST FL NORTH CORRIDOR SMOKE DOORS ARE BUCKLING ON EAHC #35434077Y | Sep 6, 2019 POP/IN-VIO | $0 |
| May 18, 2018 | Construction CLASS - 2 REISSUE-35217025L FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:3RD FL CORRIDOR SMOKE DOORS ARE BUCKLING ON EACH OTHER.1ST FL NORTH CORRIDOR SMOKE DOORS ARE BUCKLING ON EACH OTHER,ALSO NOTED:MOST #35334380Z | Aug 31, 2018 POP/IN-VIO | $0 |
| May 18, 2018 | Construction CLASS - 2 RE-ISSUE:35128034Z-FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.1ST FLR CORRIDOR DOUBLE DOOR/SMOKE DOORS OPEN AGAINST THE FLOW AGAINST EGRESS.REM:COMPLY WITH NOTICE OF VIOLATION. #35334379L | Aug 31, 2018 POP/IN-VIO | $0 |
| Jun 8, 2017 | Construction CLASS - 2 REISSUE VIOL# 35216373N FOR: FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: ON THE 1ST FLR CORRIDOR DOUBLE DOORS OPENS AGAINST THE FLOW OF EGRESS. REM: REPAIR &/OR REPLACE. #35270722J | Sep 15, 2017 POP/IN-VIO | $0 |
| Jun 8, 2017 | Construction CLASS - 2 RE-ISSUE VIOL# 35217025L FOR: FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: ON 3RD FLR CORRIDOR SMOKE DOORS ARE BUCKING ON EACH OTHER, ON 1ST FLR, NORTH CORRIDOR SMOKE DOORS ARE BUCKING ON EACH OTHE #35270720X | Sep 15, 2017 POP/IN-VIO | $0 |
| Oct 25, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.(EXTERIOR)NOTED: ON 3RD FL CORRIDOR SMOKE DOORS ARE BUCKING ON EACH OTHER. ON THE 1ST FL,NORTH CORRIDOR SMOKE DOORS ARE BUCKING ON EACH OTHER. DOUBLE DOORS AT #35217025L | Jan 6, 2017 POP/IN-VIO | $0 |
| Oct 25, 2016 | Construction CLASS - 2 FAILURE TO MAITNAIN BLDG IN CODE COMPLIANT MANNER(INTERIOR)REISSUED VIO#35188034Z NOTED: ON THE 1ST FL,CORRIDOR DOUBLE DOORS OPENS AGAINST THE FLOW OF EGRESS. REMEDY: REPAIR &/OR REPLACE. #35216373N | Jan 6, 2017 POP/IN-VIO | $0 |
| Oct 13, 2015 | Construction CLASS - 2 REISSUE #35128034Z. FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT 1ST FLOOR DOUBLE CORRIDOR SMOKE DOORS OPEN AGAINST EGRESS FLOW. RMDY: COMPLY W/NOV. #35127894Y | Jan 8, 2016 POP/IN-VIO | $0 |
| Apr 28, 2015 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT 1ST FLOOR DOUBLECORRIDOR SMOKE DOORS OPEN AGAINST EGRESS FLOW. RMDY: COMPLY WITH NOV. #35128034Z | Jun 19, 2015 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #06509 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #06510 | DOB VIOLATION - ACTIVE |
| Jun 1, 2016 | NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST FAILURE TO PERFORM CATEGORY 5 INSPECTION #02925 | DOB VIOLATION - ACTIVE |
| Jul 23, 2014 | ELEVATOR NYC DEPARTMENT OF EDUCATION #9027/520697 | DOB VIOLATION - ACTIVE |
| Jun 1, 2013 | ELEVATOR #9027/472327 | DOB VIOLATION - ACTIVE |
| Jul 21, 2010 | ELEVATOR #9027/346668 | DOB VIOLATION - ACTIVE |
| Jul 21, 2010 | ELEVATOR #9027/626668 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 1, 2016 | Elevators EVCAT5 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)