Bronx · Block 2315 · Lot 30 · 10454

2640 3 Avenue

4 floors · 16,656 sq ft · built 1931 · class N9 · owner of record: 2640 Llc

11open violations
$22,474ECB/OATH penalties owed
0HPD class C (immediately hazardous)
796dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 796 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-12 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (12) · $22,474 owed
IssuedViolationHearingBalance
Jul 28, 2026Unknown CLASS - 2
UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS. OBSERVED IN THE STAIRWAY 3A ARMORED CABLE USED TO SUPPLY POWER FOR A EXIT / EM LIGHT NEC 300.25 ARMORED CABLE RESTRICTS THE USE IN FIRE R
#39197917R
Nov 9, 2026
PENDING
$800
Jul 28, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. HOLE PENETRATIONS (PLASTIC ACCESS PANELS) NOT FIRE RATED. LOCATED THROUGHOUT BUILDING. ALSO PORTABLE AC UNITS INSTALL IN WALLS. POTENTIAL FIRE HAZARD., REP
#39197920H
Nov 9, 2026
$2,500
Jul 28, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED EXCESSIVE STORAGE IN FIRE PUMP ROOM. LOCATED AT CELLAR LEVEL., REPAIR AND/REPLACE
#39197922L
Nov 9, 2026
$2,500
Jul 28, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED STORAGE UNDERNEATH STAIRCASE. (3 WASHING MACHINES) POTENTIAL HAZARD. LOCATED AT BASEMENT LEVEL., REPAIR AND/REPLACE
#39197921J
Nov 9, 2026
$2,500
Jul 28, 2026Unknown CLASS - 1
MISCELLANEOUS VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. OBSERVED ON THE ROOF THE GENERATOR ENCLOSED MAIN BREAKER IS IN THE TRIP POSITION LEAVING IT IN A STATE OF NOT READY FOR OPERATION. ALL BACK SY
#39197916P
Oct 2, 2026
DEFAULT
$1,630
Jul 28, 2026Boilers CLASS - 2
FOUND SLANT FIN GG-300 GAS FIRED BOILER WITH LEAKING SAFETY RELIEF VALVE, EXPOSED WIRING, NO ACCESS TO CHIMNEY BASE CLEAN OUT.
#39197894N
Oct 2, 2026
DEFAULT
$1,280
Jul 28, 2026Construction CLASS - 1
ATOI OBSERVED NEWLY INSTALLED COPPER PIPE TO LAUNDRY ROOM. DRIER EXHAUST NOT TAPED OR CAPPED. MANAGING AGENT STATES NEWLY INSTALLED LAUNDRY ROOM NO PERMITS ON FILE CHECKED DOBNOW/BIS CONTRARY TO PC 106.1, MC 60
#39197911X
Oct 2, 2026
DEFAULT
$2,530
Jul 28, 2026Unknown CLASS - 2
FAILURE TO PROVIDE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTION IN DWELLING UNITS. OBSERVED THAT ALL THE PANELS THE CIRCUITS THAT ARE FEEDING THE DWELLING / SLEEPING QUARTERS ARE NOT ARC FAULT PROTECTED. ALL
#39197918Z
Oct 2, 2026
DEFAULT
$2,430
Jul 28, 2026Construction CLASS - 1
ATOI OBSERVED OBSTRUCTED SPRINKLER HEADS AND SPRINKLER HEADING MISSING SPRINKLER CAPS THROUGHOUT THE BUILDING. SPRINKLER SYSTEM NEEDS TO BE FREE OF OBSTRUCTIONS AND MAINTAINED CONTRARY TO BC 903.3.3, REPAIR AND
#39197912H
Oct 2, 2026
DEFAULT
$2,530
Jul 28, 2026Elevators CLASS - 1
CLASS 1: 1. FIREFIGHTER'S SERVICE PHASE I INOPERATIVE AS PER ASME A17.1 2.27.3. CONDITION OBSERVED: KEY ROTATES FREELY AND INITIATES LOBBY RECALL, BUT REMOVAL OF THE KEY AT THE RECALL POSITION CANCELS PHASE I A
#39197878N
Oct 2, 2026
DEFAULT
$1,280
Apr 28, 2025Construction CLASS - 2
FAILURE TO CERTIFY CORRECTION FOR VIOLATION NUMBER 39122644Y, FILE A CERTIFICATE OF CORRECTION
#39146197H
Jul 18, 2025
DEFAULT
$2,494
Aug 21, 2024Construction CLASS - 2
FACADE WORK WITHOUT PERMITS, (C HOOKS, SUPPORTING OUT-RIGGER SYSTEM, AND SUSPENDED SCAFFOLD INSTALLED TO ROOF PARAPET)., OBTAIN ALL PERMITS
#39122643M
Dec 8, 2025
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#01892
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (2) · C 0 · B 0 · A 2
IssuedClassViolationCorrect by
May 11, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 14, 2026
Jun 16, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 19, 2025

Issued in the last 120 days

DateSourceWhatNow
Jul 28, 2026ECBUnknown: UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS. OBSERVED IN THE STAIRWAY 3A ARMORED CABLE USED TO SUPPLY POWER FOR A EXIT / EM LIGHT NEC 300.25 ARMORED CABLE RESTRICTS THE USE IN FIRE ROpen
Jul 28, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. HOLE PENETRATIONS (PLASTIC ACCESS PANELS) NOT FIRE RATED. LOCATED THROUGHOUT BUILDING. ALSO PORTABLE AC UNITS INSTALL IN WALLS. POTENTIAL FIRE HAZARD., REPClosed
Jul 28, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED EXCESSIVE STORAGE IN FIRE PUMP ROOM. LOCATED AT CELLAR LEVEL., REPAIR AND/REPLACEClosed
Jul 28, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED STORAGE UNDERNEATH STAIRCASE. (3 WASHING MACHINES) POTENTIAL HAZARD. LOCATED AT BASEMENT LEVEL., REPAIR AND/REPLACEClosed
Jul 28, 2026ECBUnknown: MISCELLANEOUS VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. OBSERVED ON THE ROOF THE GENERATOR ENCLOSED MAIN BREAKER IS IN THE TRIP POSITION LEAVING IT IN A STATE OF NOT READY FOR OPERATION. ALL BACK SYOpen
Jul 28, 2026ECBBoilers: FOUND SLANT FIN GG-300 GAS FIRED BOILER WITH LEAKING SAFETY RELIEF VALVE, EXPOSED WIRING, NO ACCESS TO CHIMNEY BASE CLEAN OUT.Open
Jul 28, 2026ECBConstruction: ATOI OBSERVED NEWLY INSTALLED COPPER PIPE TO LAUNDRY ROOM. DRIER EXHAUST NOT TAPED OR CAPPED. MANAGING AGENT STATES NEWLY INSTALLED LAUNDRY ROOM NO PERMITS ON FILE CHECKED DOBNOW/BIS CONTRARY TO PC 106.1, MC 60Open
Jul 28, 2026ECBUnknown: FAILURE TO PROVIDE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTION IN DWELLING UNITS. OBSERVED THAT ALL THE PANELS THE CIRCUITS THAT ARE FEEDING THE DWELLING / SLEEPING QUARTERS ARE NOT ARC FAULT PROTECTED. ALLOpen
Jul 28, 2026ECBConstruction: ATOI OBSERVED OBSTRUCTED SPRINKLER HEADS AND SPRINKLER HEADING MISSING SPRINKLER CAPS THROUGHOUT THE BUILDING. SPRINKLER SYSTEM NEEDS TO BE FREE OF OBSTRUCTIONS AND MAINTAINED CONTRARY TO BC 903.3.3, REPAIR ANDOpen
Jul 28, 2026ECBElevators: CLASS 1: 1. FIREFIGHTER'S SERVICE PHASE I INOPERATIVE AS PER ASME A17.1 2.27.3. CONDITION OBSERVED: KEY ROTATES FREELY AND INITIATES LOBBY RECALL, BUT REMOVAL OF THE KEY AT THE RECALL POSITION CANCELS PHASE I AOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 11:14 PM ET. BBL 2023150030.