Manhattan · Block 891 · Lot 23 · 10016

264 Lexington Avenue

12 floors · 35 apartments · 35,734 sq ft · built 1924 · class D4 · owner of record: Murray Hill Owners Corp

33open violations
$10,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-21 (Accepted). Agency page

Dec 31, 2026
in 47 days
1 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 35,734 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $142,250 in late-filing or failure-to-file penalties. Agency page

On fileCycle 10 filing on record: SAFE (2026-01-19)

Open violations

ECB / OATH (1) · $10,000 owed
IssuedViolationHearingBalance
Apr 8, 2025Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #902714. REMEDY: SUBMIT ACCEPTABLE REQU
#37034588X
Jul 3, 2025
DEFAULT
$10,000
DOB (7)
IssuedViolationStatus
May 30, 2014(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
#01948
DOB VIOLATION - ACTIVE
May 30, 2014(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
#01947
DOB VIOLATION - ACTIVE
Nov 8, 1993CONSTRUCTION

#B5PR09
DOB VIOLATION - ACTIVE
Nov 8, 1993CONSTRUCTION

#BSPR08
DOB VIOLATION - ACTIVE
Nov 8, 1993CONSTRUCTION

#B5PR09
VIOLATION UNSERVED ECB-ACTIVE
Nov 8, 1993CONSTRUCTION

#B5PR08
VIOLATION UNSERVED ECB-ACTIVE
May 30, 1989CONSTRUCTION

#C2TZ01
DOB VIOLATION - ACTIVE
DOB NOW Safety (9)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
May 30, 2014Elevators ACC1
Active
May 30, 2014Elevators ACC1
Active
HPD (16) · C 0 · B 7 · A 9
IssuedClassViolationCorrect by
Jun 20, 2016BApt 4 · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT STOVE IN THE KITCHEN LOCATED AT APT 4, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJul 25, 2016
Jun 7, 2016A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORYSep 10, 2016
Jun 7, 2016A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORYSep 10, 2016
Jun 7, 2016A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORYSep 10, 2016
Jun 7, 2016A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYSep 10, 2016
Jun 7, 2016A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORYSep 10, 2016
Jul 1, 2008AD26-10.01 ADM CODE REFIT BULKHEAD AT STAIRS TO ROOF WEST.Oct 4, 2008
Jul 1, 2008AD26-10.01 ADM CODE REFIT 6 STY WEST FIRE STAIRS.Oct 4, 2008
Jul 1, 2008AD26-10.01 ADM CODE REFIT 4 STY WEST FIRE STAIRS.Oct 4, 2008
Jul 1, 2008BApt 3C · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 3 STY SOUTHWEST APT 3C OHOS. , SECTION '' ''Aug 5, 2008
Jul 1, 2008BApt 3C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILING THROUGHOUT 3 STY NORTHWEST APT 3C. , SECTION '' ''Aug 5, 2008
Jul 28, 2006A§ 27-2005 ADM CODE REFIT NORTHWEST FIRE STAIRS 10 STY PUBLIC HALL.Nov 12, 2006
Jun 14, 2004BApt 7C · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER WINDOW SASH NORTH WINDOW IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 24, 2004
Jun 4, 1991BApt 7C · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING MISSING GLASS LOWER SASH FRONT ROOM 7 STY SOUTH APT 7C. , SECTION '' ''Jul 22, 1991
Oct 30, 1990BApt 3C · § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 3 STY NORTHWEST APT 3C. , SECTION '' ''Dec 17, 1990
May 1, 1990BApt 7C · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTERBALANCE UPPER SASH NORTHWEST ROOM WINDOW WEST 7 STY NORTHEAST APT 7C. , SECTION '' ''Jun 18, 1990

Check the agency records