5 floors · 94 apartments · 128,636 sq ft · built 1920 · class R4 · owner of record: Bommer Building Condominium
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 70 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 86 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 128,636 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 801 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1924). Agency page | Dec 31, 2034 in 2992 days | Next due 2034 |
| Annual boiler inspection (4 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-04 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 24, 2026 | Construction CLASS - 2 ATOI, OBSERVED PERMIT TO CURE ECB VIOLATION 339125948R WORK WITHOUT A PERMIT IN APARTMENTS 2D, 2E, AND 3C, PERMIT # B01138698-I1-EL, EXPIRING 01/31/2027 IS NOT POSTED ANYWHERE ON PREMISES FOR PUBLIC VIEWING. PE #39205567N | Dec 2, 2026 PENDING | $300 |
| Aug 5, 2026 | Construction CLASS - 1 WORK WITHOUT A PERMIT. STRUCTURAL WORK NOTED. AT THE TIME OF INSPECTION, I OBSERVED A NEWLY INSTALLED BALCONY OUTSIDE OF APARTMENT 2B. BALCONY CONSTRUCTED WITH STEEL BEAMS APPROX. 13' - 7"W X 16'L WITH STEEL DE #39199299H | Oct 21, 2026 PENDING | $2,500 |
| Aug 5, 2026 | Construction CLASS - 2 WORK WITHOUT A PERMIT. ELECTRICAL WORK NOTED. AT THE TIME OF INSPECTION, I OBSERVED ELECTRICAL LIGHTING ON OUTSIDE WALL AT EXPOSURE 1. WORK IS COMPLETED 1000%, NO FILLINGS IN DOB RECORDS., OBTAIN ALL PERMITS #39199298X | Oct 21, 2026 PENDING | $1,250 |
| Aug 5, 2026 | Construction CLASS - 1 WORK WITHOUT A PERMIT. CONSTRUCTION WORK NOTED. AT THE TIME OF INSPECTION I OBSERVED NEWLY INSTALLED PARTITIONS, 3 WINDOWS, DOOR AND ROOF ON THE EXTERIOR BALCONY APPROX. 13'-7"W X 16' L X 8' H AT APARTMENT 2C. #39199297Y | Oct 21, 2026 PENDING | $2,500 |
| Sep 26, 2024 | Unknown CLASS - 2 E.C.B VIOLATION ISSUED FOR WORK ELECTRICAL WORK WITHOUT A PERMIT AT TIME OF INSPECTION OBSERVED 6 A.C SPLIT UNITS INSTALLED WITH ELECTRICAL DISCONNECT BOX TO PROVIDE POWER TO THE UNITS AT EXPOSURE 1, OBTAIN PER #39125948R | Jul 14, 2025 IN VIOLATION | $400 |
| Sep 23, 2024 | Construction CLASS - 2 TIME OF INSPECTION OBSERVED DOOR TO APARTMENT 3C RELOCATED AND ENLARGED. OBSERVED DOOR OPENING APPROX. 3FT WIDE AND 8 FT. AT HEIGHT WITH PORTION OF PUBLIC HALLWAY WALL REMOVED., OBTAIN ALL PERMITS #39125583N | Jul 14, 2025 IN VIOLATION | $1,250 |
| Feb 5, 2014 | Elevators CLASS - 2 02X07,67M07. 02- NO AUDIO BELL OR E-STOP. 67- NO PHONE IN ELEVATOR = (MOD. JOB 2004) #38229763K | Mar 24, 2014 WRITTEN OFF | $0 |
| Oct 6, 2007 | Construction Hazardous WORK W/O PERMIT. WORK NOTED: AT FRONT OF APT 5E (SIDE FACING CLASSON AVE) ERECTED STEEL FRAMED PORCH. NOTES AT ABOVE MENTIONED PREMISES CUT OUT MADE THROUGH FRONT PERIMETER WALL & INSTALLED STEEL STRUCTURE #34613341L | Sep 21, 2009 WRITTEN OFF | $0 |
| Oct 6, 2007 | Construction Hazardous WORK W/O PERMIT. WORK NOTED: AT FRONT OF APT 1E (SIDE FACING CLASSON AVE) ERECTED STEEL FRAMED PORCH. NOTE AT ABOVE MENTIONED PREMISES CUT THROUGH FRONT PERIMETER WALL & INSTALLED A STEEL STRUCTURE APPROX #34613339M | Jun 25, 2009 IN VIOLATION | $0 |
| Oct 6, 2007 | Construction Hazardous WORK W/O PERMIT. WORK NOTED: AT FRONT OF APT 2E (SIDE FACING CLASSON AVE) ERECTED STEEL FRAMED PORCH. NOTE AT ABOVE MENTIONED PREMISES CUT OUT MADE THROUGH FRONT PERIMETER WALL & INSTALLED STEEL STRUCTURE APPRO #34613340J | Jun 25, 2009 WRITTEN OFF | $0 |
| Apr 25, 2007 | Elevators Non-Hazardous 83M05.83M-DEVICE TOTALLY REMOVED ILLEGALY FILE APPLICATION & OBTAIN PERMIT.CALL 212-566-5539 FOR TEST INSPECTION. #38165860M | Aug 18, 2008 WRITTEN OFF | $0 |
| Apr 25, 2007 | Elevators Non-Hazardous 12Q07.12Q-REPLACE DROPPED CEILING OR PROVIDE GUARDS FOR CAR LIGHTING. #38165861Y | Jun 18, 2007 WRITTEN OFF | $0 |
| Jan 17, 2007 | Elevators Non-Hazardous 66O02,64L10,71D06,59Q03,55O02,51O02,52O02,55D06,38O02,05O02,03M07,40L10,39I10.66-CLEAN PIT.64-PIT LIGHT NOT WORKING.71-UNDER CAR LIGHT UNSECURE.59-MOTOR ROOM LIGHTS UNGUARDED.55-CLEAN MAIN MACHINE.51-CLEAN HOIS #38163149L | Mar 19, 2007 WRITTEN OFF | $0 |
| Dec 19, 2005 | Local Law Non-Hazardous FAILURE TO PROVIDE ELEVATOR LANDING SIGN THAT SHALL READ: " IN CASE OFFIRE USE STAIRS, UNLESS OTHERWISE INSTRUCTED" AT THE ELEVATOR: BANK ONFLOOR 2 TO 6. -FAILURE TO PROVIDE 3-INCH MINIMUM HIGH ALPHABETIC #34416747Z | Mar 28, 2006 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous 4B/36/19A. 4B-HAZARDOUS/NOT WIRED INTO THE SYSTEM. 19A-NOT WIRED. #32048071Z | Dec 5, 2005 IN VIOLATION | $0 |
| May 10, 2005 | Boilers Hazardous 4B/36/19A. 4B-HAZARDOUS-NOT WIRED. 19A-NOT WIRED. #32048072K | Dec 5, 2005 IN VIOLATION | $0 |
| May 10, 2005 | Boilers Hazardous 4B/36/19A. 4B-HAZARDOUS-NOT WIRED. 19A-NOT WIRED. #32048073M | Dec 5, 2005 IN VIOLATION | $0 |
| May 10, 2005 | Boilers Non-Hazardous 4A/24B/50A/BQ9/19B/50/36. 4A-HAZARDOUS. 24B-OUTSIDE THE BOILER ROOM. 50-INCORRECT SIZED BACKFLOW PREVENTER FOR TOTAL BOILERS OVER 350,000 BTU'S. 50A-RELIEF VALVE IS NOT INSTALLED IN THE UPRIGHT POSITION WITH TH #32047734X | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36/32A. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED. 32A-AQUASTAT COVER PLATE IS MISSING EXPOSING THE WIRES. #32047735H | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous 50/JUA/36/44C/BQ9. 50-HAZARDOUS-DISCHARGE PIPE FROM THE RELIEF VALVE IS TOUCHING THE FLOOR. 44C-LEAKING. 50A-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED AT THE BOTTOM. BQ9-ENERJET BG-3 H #32047736J | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/32A/36. BQ9-ENERJET HOT WATER BOILER BG-3 HAS NO BL WORK TYPE. 32A-CIRCULATOR PUMP/MOTOR WIRING. #32047737L | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED AT THE BOTTOM. BQ9-ENERJET BG-3 HOT WATER BOILER HAS NO BL WORK TYPE. #32047738N | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET MODEL BG3 HAS NOT BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED AT THE BOTTOM. #32047739P | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET MODEL #BG3 HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED AT THE BOTTOM #32047740M | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET MODEL #BG3 HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS LOCATED AT THE BOTTOM #32047741Y | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/32A/36/50. BQ9-ENERJET MODEL #BG3 HAS NOT BL WORK TYPE. 32A-MISSING COVER PLATE ON CIRCULATOR PUMP EXPOSING THE WIRES. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED AT THE BOTTOM #32047742X | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET MODEL #BG3 HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER AT THE BOTTOM LOCATION OF THE BOILER #32047743H | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/44C/36/50. BQ9-ENERJET BOILER #BG3 HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED AT THE BOTTOM. #32047744J | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/44C/36/50. BQ9-ENERJET BOILER MODEL #BG3 HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED AT THE BOTTOM. #32047745L | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET MODEL #BG-3 HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED AT THE BOTTOMOF THE BOILER. #32047746N | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/44C/36/50. BQ9-ENERJET MODEL #BG-3 HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED AT THE BOTTOM OF THE BOILER #32047747P | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/36 4A/19B 4A HAZARDOUS. BQ9-UTICA BOILER HAS NO BL WORK TYPE. #32048032X | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36/50A. BQ9-ENERJET BG-3 HOT WATER BOILER HAS NO BL WORK TYPE. 50-HAZARDOUS-DISCHARGE PIPE FROM THE SAFETY VALVE IS TOUCHING THE FLOOR OF THE BOILER ROOM. 50A-DAMPER ON TOP OF THE BOILER IS BY PASSED #32047748R | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET HOT WATER BOILER MODEL #BG-3 HAS NO BL WORK TYPE. 50-DAMPER ON TOP OF THE BOILER IS BY PASSED. #32047749Z | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/4B/36/44C. 4B-HAZARDOUS/DISCONNECTED. BQ9-ENERJET BOILER HAS NO BLWORK TYPE. #32047975R | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-HAZARDOUS-RELIEFVALVE DISCHARGE PIPE TOUCHES THE FLOOR. #32047976Z | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/36/4A/19B/50/38 BQ9-SLANT FIN BOILER HAS NO BL WORK TYPE 4A HAZARDOUS 50-RELIEF VALVE IS NOT INSTALLED IN THE UPRIGHT POSITION WITH THE TEST LEVEL ON TOP #32048000L | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/36/4A/19B BQ9-SLANT FIN BOILER HAS NO BL WORK TYPE 4A HAZARDOUS #32048001N | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/36 4A/19B 50 4A HAZARDOUS. BQ9- SLANT FIN HOT WATER BOILER HAS NO BL WORK TYPE. 50-RELIEF VALVE IS NOT INSTALLED UPRIGHT. #32048002P | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/36 4A/19B 38/50 50A BQ9- SLANT FIN BOILER HAS NO BL WORK TYPE 4A HAZARDOUS. 50- FAN INDUCER IS NOT WIRED PROPERLY. 50A- EXHAUST FAN IN BOILER ROOM. #32048003R | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/36 4A/19B 50 BQ9- SLANT FIN BOILER HAS NO BL WORK TYPE. 4A HAZARDOUS. 50- RELIEF VALVE IMPROPERLY INSTALLED. #32048004Z | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/36 4A/19B 50 BQ9- SLANT FIN BOILER HAS NO BL WORK TYPE 4A-HAZARDOUS. 50- RELIEF VALVE IS IMPROPERLY INSTALLED. #32048005K | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED. #32048018J | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/36 4A/19B 50/50A 50B BQ9- SLANT FIN BOILER HAS NO BL WORK TYPE 4A HAZARDOUS. 50- FAN INDUCER IS IMPROPERLY INSTALLED 50A- EXHAUST FAN INTHE BOILER ROOM 50B- BACK FLOW PREVENTOR HAS A PLUG IN THE DISCHARGE. #32048006M | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/36 4A/19B 50 BQ9- SLANT FIN BOILER HAS NO BL WORK TYPE 4A- HAZARDOUS. 50- RELIEF VALVE IS IMPROPERLY INSTALLED. #32048007Y | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Hazardous BQ9/36 4A/19B 50 BQ9- SLANT FIN BOILER HAS NO BL WORK TYPE 4A HAZARDOUS. 50- RELIEF IS IMPROPERLY INSTALLED. #32048008X | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED. #32048009H | Dec 5, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER,WHERE IT IS INSTALLED. #32048010P | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED. #32048011R | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/50A/36/32A. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED. 32A-COVERPLATE MISSING ON MANUAL RESET AGUASTAT EXPOSING THE WIRES. 50A-HAZARDO #32048012Z | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL-WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS LOCATED. #32048013K | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED. #32048014M | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36/44C. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-RELIEF VALVEDISCHARGE PIPE HAS A THREADED END. #32048015Y | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS LOCATED. #32048016X | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS LOCATED #32048017H | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS INSTALLED. #32048019L | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36/32A. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS LOCATED. 32A-MISSING COVER ON RELAY EXPOSING THE WIRES. #32048020Z | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS LOCATED. #32048021K | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS LOCATED. #32048022M | Oct 31, 2005 WRITTEN OFF | $0 |
| May 10, 2005 | Boilers Non-Hazardous BQ9/50/36. BQ9-ENERJET BOILER HAS NO BL WORK TYPE. 50-LOW WATER CUT OFF DOES NOT PROTECT THE BOILER WHERE IT IS LOCATED. #32048023Y | Oct 31, 2005 WRITTEN OFF | $0 |
Showing 60 of 111. Full list on the agency site.
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15250 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15234 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15226 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15247 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15237 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15229 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15241 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15232 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15259 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15254 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15238 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15233 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15258 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15249 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15244 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15243 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15251 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15246 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15228 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15245 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15252 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15257 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15248 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15240 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15242 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15231 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15256 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15260 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15253 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15255 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15236 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15239 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15235 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15227 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15225 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15230 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13953 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13987 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13986 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13985 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13984 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13983 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13982 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13981 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13980 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13979 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13978 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13977 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13976 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13975 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13974 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13973 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13972 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13971 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13970 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13952 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13969 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13968 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13967 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #13966 | DOB VIOLATION - ACTIVE |
Showing 60 of 400. Full list on the agency site.
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-CAT1-NJ Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-NJ Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
Showing 60 of 400. Full list on the agency site.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 7, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 10, 2026 |
| Nov 5, 2025 | B | Apt 3Q · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB, IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 3Q, 327th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''272 BLDG'' | Dec 10, 2025 |
| Nov 3, 2025 | A | Apt 3Q · § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE VISIBLE MOLD AT CAULKING AND GROUT JOINTS OF THE CERAMIC TILES AT NORTH, EAST AND SOUTH WALLS AROUND BATHTUB, IN THE 1st BATHROOM FROM EAST LOCATED AT APT 3Q, 327th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''272 BLDG'' | Feb 6, 2026 |
| Nov 3, 2025 | B | Apt 3Q · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HINGES OF THE BASE CABINET DOORS 1ST AND 3D FROM SOUTH AT WEST, IN THE KITCHEN LOCATED AT APT 3Q, 327th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''272 BLDG'' | Dec 8, 2025 |
| Nov 3, 2025 | B | Apt 3Q · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH AND WEST WALLS, IN THE BATHROOM LOCATED AT APT 3Q, 327th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''272 BLDG'' | Dec 8, 2025 |
| Nov 3, 2025 | B | Apt 3Q · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3Q, 327th STORY, 2nd APARTMENT FROM NORTH AT EAST , S | Dec 8, 2025 |
| Nov 3, 2025 | C | Apt 3Q · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3Q, 327th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''272 BLDG'' | Nov 17, 2025 |
| Nov 3, 2025 | B | Apt 3Q · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3Q, 327th STORY, 2nd APARTMENT FROM NORTH AT EAST , | Dec 8, 2025 |
| Nov 3, 2025 | A | Apt 3Q · § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE VISIBLE MOLD AT GROUT JOINTS OF THE CERAMIC TILES AT NORTH AND SOUTH WALLS AROUND BATHTUB IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 3Q, 327th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''272 BLDG'' | Feb 6, 2026 |
| Oct 20, 2025 | A | Apt BI · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT EAST WALL, WEST WALL AND CEILING IN THE 2nd BATHROOM FROM EAST LOCATED AT BSMT-APT BI, 3rd BSMT-APT FROM WEST AT NORTH , SECTION ''272'' | Jan 23, 2026 |
| Oct 20, 2025 | C | Apt 3M · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3M, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''272'' | Nov 3, 2025 |
| Oct 20, 2025 | C | Apt BI · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT BSMT-APT BI, 3rd BSMT-APT FROM WEST AT NORTH , SECTION ''272'' | Nov 3, 2025 |
| Oct 20, 2025 | B | Apt BI · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BI, 3rd BSMT-APT FROM WEST AT NORTH , SECTION ''272'' | Nov 24, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
| Sep 24, 2026 | ECB | Construction: ATOI, OBSERVED PERMIT TO CURE ECB VIOLATION 339125948R WORK WITHOUT A PERMIT IN APARTMENTS 2D, 2E, AND 3C, PERMIT # B01138698-I1-EL, EXPIRING 01/31/2027 IS NOT POSTED ANYWHERE ON PREMISES FOR PUBLIC VIEWING. PE | Open |
| Aug 5, 2026 | ECB | Construction: WORK WITHOUT A PERMIT. STRUCTURAL WORK NOTED. AT THE TIME OF INSPECTION, I OBSERVED A NEWLY INSTALLED BALCONY OUTSIDE OF APARTMENT 2B. BALCONY CONSTRUCTED WITH STEEL BEAMS APPROX. 13' - 7"W X 16'L WITH STEEL DE | Open |
| Aug 5, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING AND ALL PARTS THEREOF IN A CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, I OBSERVED THE 5-STORY BUILDING FACADE AT REAR (EXP. 3) WITH DEFECTS AROUND THE STEEL BEAMS BALCONIES., | Closed |
| Aug 5, 2026 | ECB | Construction: WORK WITHOUT A PERMIT. ELECTRICAL WORK NOTED. AT THE TIME OF INSPECTION, I OBSERVED ELECTRICAL LIGHTING ON OUTSIDE WALL AT EXPOSURE 1. WORK IS COMPLETED 1000%, NO FILLINGS IN DOB RECORDS., OBTAIN ALL PERMITS | Open |
| Aug 5, 2026 | ECB | Construction: WORK WITHOUT A PERMIT. CONSTRUCTION WORK NOTED. AT THE TIME OF INSPECTION I OBSERVED NEWLY INSTALLED PARTITIONS, 3 WINDOWS, DOOR AND ROOF ON THE EXTERIOR BALCONY APPROX. 13'-7"W X 16' L X 8' H AT APARTMENT 2C. | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)