6 floors · 42 apartments · 37,482 sq ft · built 1930 · class D1 · owner of record: 260 Seaman Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 37,482 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-21 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 1, 2026 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AS NOTED AT THE TIME OF INSPECTION I OBSERVED ON EXPOSURE #1 NORTH ELEVATION: SEVERAL FIRE ESCAPES HAS OBJECTS SITTING ON THE LANDINGS. AT MULTIPLE FLOOR, OBSTRU #35730025Z | Sep 24, 2026 IN VIOLATION | $0 |
| Mar 27, 2026 | Elevators CLASS - 1 DLM NOT INSTALLED WRITE-UP: CLASS 1 ITEM: NO DOOR LOCK MONITORING INSTALLED ON THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 BUILDING CODE. THIS IS A FEATURE WHICH ENSURES PASSENGER SAFETY. #39182223K | Jun 4, 2026 ADMIT/IN-VIO | $0 |
| Nov 12, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OF 6 STORY RESIDENTIAL BUILDING OBSERVED SIDEWALK SHED IN PLACE NOT MAINTAINED PER CODE 1. PARAPET PANEL NOT SECURED 2. CATCH ALL ONLY ON 1 SIDE OF SHED CAUSING HAZARDOUS CONDITIONS.MAINTA #39546869Y | Feb 19, 2026 IN VIOLATION | $2,400 |
| Apr 11, 2024 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #914054. REMEDY: SUBMIT ACCEPTABLE REQU #37027828K | May 22, 2025 ADMIT/IN-VIO | $0 |
| Apr 7, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE:OBSERVED AT EXPOSURE#1(SEAMAN AVE) CRACKED COPING STONE AT PARAPET,MULTIPLE CRACKED WINDOW SILLS,MULTIPLE DAMAGED/OPEN MORTAR JOINT AT WINDOW #35548899Z | Oct 7, 2021 IN VIOLATION | $0 |
| Jan 29, 2021 | Construction CLASS - 1 1RCNY 103-04 OWNER FAILED TO MAKE NECESSARY REPAIRS TO BUILDING EXTERIOR FACADE IN TIME FRAME RECOMMENDED BY QEWI. AS NOTED A SWARMP FACADE REPORT WAS SUBMITTED TO THE DOB W/ A RECOMMENDED REPAIR DATE OF 2/1/20 #35549517Z | Feb 3, 2022 IN VIOLATION | $0 |
| Dec 26, 2013 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING.NORTH ELEVATION EXPOSURE#4 OBSERVE BLOCKS OF WOOD UNDER A/C UNIT; WEST ELEVATION, EXPOSURE#3 OBSERVE FLOWER POTS STORE ON FIRE ESCAPE LANDING; SOUTH ELEVATION,EXPOSURE#1 #35024213H | Jun 5, 2014 ADMIT/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #01104 | DOB VIOLATION - ACTIVE |
| Apr 28, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00099 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #05001 | DOB VIOLATION - ACTIVE |
| Apr 21, 2004 | LOCAL LAW 10/81 - ELEVATOR #01715 | DOB VIOLATION - ACTIVE |
| Jun 5, 1991 | ELEVATOR DEVICE #1P8288 #1176C01 | VIOLATION UNSERVED ECB-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| May 15, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Feb 22, 2023 | Facades FISPNRF CYCLE 9B NO REPORT FILED | Active |
| Apr 28, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 14, 2016 | Elevators ACC1 | Active |
| Apr 21, 2004 | Elevators LL1081 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Mar 17, 2021 | A | Apt F3 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT F3, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 20, 2021 |
| Date | Source | What | Now |
|---|---|---|---|
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)