22 floors · 531,270 sq ft · built 1952 · class O4 · owner of record: Am 260 Madison Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 531,270 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page | Feb 21, 2028 in 475 days | No Cycle 10 report on record yet |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 868). Agency page | Dec 31, 2028 in 789 days | Next due 2028 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1154 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 28, 2026 | Construction CLASS - 1 FAILURE TO SUBMIT A CERTIFICATE OF CORRECTION AND ENGINEER'S REPORT OF VIOLATION #37025585X ISSUED ON 10-11-2023 FOR UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER., COMPLY WITH COMMISSIONER'S ORDER #39197896R | Nov 12, 2026 PENDING | $6,250 |
| Jul 28, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED MANY CRACKS IN STRUCTURE OF GARAGE ALSO FAILURE TO SUBMIT A CERTIFICATE OF CORRECTION OF VIOLATION #39085880X ISSUED ON 05-09-2023 FOR FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIA #39197897Z | Nov 12, 2026 PENDING | $6,250 |
| Jun 17, 2024 | Construction CLASS - 2 AC27-929.1 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE FINAL SPRINKLER REPORT PREPARED BY REGISTEREED DESIGN PROFESSIONAL IN AN OFFICE BUILDING 100 FEET OR MORE IN HEIGHT IN E #37028814Y | Nov 7, 2024 ADMIT/IN-VIO | $0 |
| May 13, 2024 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMISSIONER'S ORDER. NOTE:-OBSERVED RESPONDENT FAILURE TO COMPLY WITH PREVIOUS VIOLATION #35680025X, 35682227N DATED 01/29/2024 AND DOB VIOLATION #012924LL10501MK, WHICH RE #35685150H | Sep 5, 2024 ADMIT/IN-VIO | $0 |
| Jan 29, 2024 | Construction CLASS - 1 28-323.1 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITIONS. AS NOTED: ON AN ACTIVE PARKING STRUCTURE CONSISTING OF 1 LEVEL BELOW GL PS BELOW 23 FL BUILDING: OBSERVED(1) SPALLING CONCRETE/EXPOSED RE-BAR U #35680025X | Jun 6, 2024 IN VIOLATION | $0 |
| Jan 29, 2024 | Construction CLASS - 1 28-323.8 AND RCNY-103-13(5) FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING STRUCTURE AND APPURTENANCES CONFORM TO THE PREVIOUS OF ADMIN CODE AFTER UNSAFE NOTIFICATION FILED BY PQSI#UNPS-M0002048 DATED #35682227N | Jun 6, 2024 IN VIOLATION | $0 |
| Oct 11, 2023 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-01348,DATED 5/9/2023.RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS.AS OF 10/11/2023,A #37025585X | Mar 28, 2024 ADMIT/IN-VIO | $0 |
| May 9, 2023 | Construction CLASS - 1 OBSERVED THE GARAGE WITH A CRACK AT BOTTOM OF THE RAMP THAT IS AROUND 40' LONG AND RUNS THROUGH SEVERAL SLABS AND BEAMS. THE AREA WHERE THE CARS ARE BEING STORED HAVE BI-DIRECTIONAL CRACKS, SPALLING PAINT & MAS #39085880X | Jan 25, 2024 IN VIOLATION | $0 |
| Feb 28, 2023 | Construction CLASS - 2 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BUILDING 100 FEET OR MORE IN HE #37025428M | Jan 18, 2024 IN VIOLATION | $0 |
| Nov 1, 2021 | Construction CLASS - 2 27-929.1 AC27-929.1,FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OFAUTOMATIC SPRINKLERS&FILE FINAL SPRINKLER REPORT PREPARED BY REGISTERED DESIGN PROFESSIONAL IN OFFICE BLDG 100' OR MORE IN HT IN EXISTENCE O #37022506P | Mar 17, 2022 ADMIT/IN-VIO | $0 |
| Jul 13, 2020 | Construction CLASS - 2 SEC. AC 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEMOF AUTOMATIC SPRIKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BLDG 100 FEET OR #37019807L | Jul 8, 2021 IN VIOLATION | $0 |
| May 4, 2020 | Cranes and Derricks CLASS - 1 AT TIME OF INSPECTION , RESPONDENT FAIL TO RENEW GENERAL LIABILITY INSURANCE EXPIRED ON 02/04/2020, OBTAIN BOND AND/OR INSURANCE AND FILE WITH THE DEPARTMENT #39021866R | Sep 23, 2021 DEFAULT | $25,000 |
| May 4, 2020 | Cranes and Derricks CLASS - 1 AT TIME OF INSPECTION , RESPONDENT FAIL TO RENEW WORKERS COMP INSURANCE EXPIRED ON 02/16/2020, OBTAIN/MAINTAIN WORKERS COMPENSATION INSURANCE #39021865P | Sep 23, 2021 DEFAULT | $25,000 |
| Nov 15, 2019 | Construction CLASS - 2 SEC. A.C.27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BLDG 100 FEET #37016379K | May 14, 2020 IN VIOLATION | $0 |
| Nov 8, 2019 | Construction CLASS - 1 FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED AT THE TIME OF MY INSPECTION I OBSERVED A FACADE ALT-2 JOBSITE WITH THE INSTALLATION OF METAL COPING RAILINGS AN SEALANT IN THE SCOPE AT WORK.THE INSTALLATION OF #35460155J | Sep 23, 2021 IN VIOLATION | $0 |
| Jul 21, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES. NOTED: AT BLDG ENTRANCE A SECTION OF GRANTE APPROX 10'X12'DISLODGED. SIDEWALK SHED IN PLACE #122819058. REMEDY: COMPLY W/CODE,MAINTAIN EXTERIOR OF BLDG. #35201054Y | Sep 8, 2016 IN VIOLATION | $0 |
| Nov 9, 2013 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT GARAGE CELLAR AREA MARKED '4' SPALLING CONCRETE MASONRY CEILING W/EXPOSED REBAR & ERODING I BEAMS. REMEDY: REPAIR CONCRETE MASONRY. #35033468Y | Jan 30, 2014 WRITTEN OFF | $0 |
| Feb 20, 2007 | Construction Non-Hazardous SECT.27-1009(B)FAILURE TO SAFEGUARD,PUBLIC IN THAT SIDEWALK SHED WAS INSTALLED W/ 12FT SIDEWALLS THAT IS LOADED IN EXCESS OF ITS DESIGN CAPACITY CREATING A HAZARDOUS CONDITION TO THE PUBLIC.REMEDY:RESTORE #34563237Z | Apr 12, 2007 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 23, 2024 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023) #00671 | DOB VIOLATION - ACTIVE |
| May 15, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00018 | DOB VIOLATION - ACTIVE |
| May 1, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00013 | DOB VIOLATION - ACTIVE |
| Nov 1, 2023 | FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) FAILURE TO CORRECT SWARMP CONDITIONS #00152 | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00300 | DOB VIOLATION - ACTIVE |
| May 9, 2023 | CONSTRUCTION THE OCCUPIED PARKING STRUCTURE WITH CONCRETE FRAMING OBSERVED WITH A CRACK AT BOTTOM OF THE RAMP THAT IS AROUND 40 LONG AND RUNS THROUGH SEVERAL SLABS AND BEAMS. THE AREAS WHERE THE CARS ARE BEING STORED HAVE BI-DIRECTIONAL CRACKS, EXCESSIVE SPALLING MASONRY, HOLES AND WATER PENETRATION IN VARIOUS A #23-01348 | DOB VIOLATION - ACTIVE |
| Apr 22, 2023 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022) #00465 | DOB VIOLATION - ACTIVE |
| Feb 21, 2023 | HAZARDOUS CONDITION (FACADE) CYCLE 9B UNSAFE REPORT FILED #910929 | DOB VIOLATION - ACTIVE |
| Sep 3, 2019 | SPRINKLER FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019 #NRF00242 | DOB VIOLATION - ACTIVE |
| May 31, 2015 | CONSTRUCTION STRUCK BY DEBRIS CREATED BY THE IMPACT OF FALLING MECHANICAL EQUIPMENT AT 261 MADISON AVE #CNE01LC | DOB VIOLATION - ACTIVE |
| May 31, 2015 | CONSTRUCTION #NE01LC | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 2, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 5) | Active |
| Dec 31, 2024 | Parking Structures FTC-PS-UNSAFE Unsafe report of parking structures filed. | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Jun 23, 2024 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| May 15, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| May 1, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 1, 2023 | Facades FISPFCS CYCLE 9B FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Apr 22, 2023 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Feb 21, 2023 | Facades FISPHAZ CYCLE 9B UNSAFE REPORT FILED | Active |
| Sep 3, 2019 | Sprinklers FTF-SP-FINAL | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 2, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 28, 2026 | ECB | Construction: FAILURE TO SUBMIT A CERTIFICATE OF CORRECTION AND ENGINEER'S REPORT OF VIOLATION #37025585X ISSUED ON 10-11-2023 FOR UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER., COMPLY WITH COMMISSIONER'S ORDER | Open |
| Jul 28, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED MANY CRACKS IN STRUCTURE OF GARAGE ALSO FAILURE TO SUBMIT A CERTIFICATE OF CORRECTION OF VIOLATION #39085880X ISSUED ON 05-09-2023 FOR FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIA | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)