Bronx · Block 2266 · Lot 5 · 10454

260 Brook Avenue

6 floors · 25 apartments · 23,329 sq ft · built 1915 · class C7 · owner of record: 260 Brook Llc

25open violations
$3,125ECB/OATH penalties owed
6HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-17 (Accepted). Agency page

Dec 31, 2026
in 66 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 797 days
Next cycle year 2028

Open violations

ECB / OATH (1) · $3,125 owed
IssuedViolationHearingBalance
Jan 25, 2021Boilers CLASS - 2
BLR. DRAIN LEAK-DOGLEGS MISSING FRONT AND REAR-NO VENT PIPE FROM GAS REGULATOR-STOP LEFT IN DRAFT REG.-FLUE PIPE FOR HLW NOT PROPERLY SUP'TED-NO BODY DRAIN ON SAFETY VALVE-OPEN ELECTRICAL BOX BACK OF BOILER-INS
#39035309L
Mar 19, 2021
DEFAULT
$3,125
DOB (4)
IssuedViolationStatus
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
#40758
DOB VIOLATION - ACTIVE
May 10, 2022CONSTRUCTION
EMERGENCY WORK ORDER DUE TO DEFECTIVE FACADE AT EXP1 WEST AND EXP2 NORTH. DETERIORATED MORTAR JOINTS AT 5FL AT WEST AND NORTH ELEVATIONS (EXP 1,2). REMEDY: IMMED PROVIDE SIDEQALK SHED AT EXP1,2(WEST & NORTH) 25 LINEAR FEET EACH TO SECURE THE PUBLIC SAFETY
#FA0102MH
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#06806
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#06807
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
HPD (16) · C 6 · B 8 · A 2
IssuedClassViolationCorrect by
Sep 11, 2025CApt UNIT11 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT UNIT11, 4th STORY, 1st APARTMENT FROM NORTH AT EASTOct 7, 2025
Sep 11, 2025CApt UNIT11 · 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GOct 7, 2025
Sep 11, 2025BApt UNIT11 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOORS AND DRAWERS AT UPPER AND LOWER CABINETS IN THE KITCHEN LOCATED AT APT UNIT11, 4th STORY, 1st APARTMENT FROM NORTH AT EASTOct 16, 2025
Apr 21, 2025A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER (SHOE) TACK WELDED PROPERLY SECURE BY USING APPROPRIATE NUTS AND BOLTS AT FIRE ESCAPE AT WEST EXTERIOR WALL (BUILDING FRONT)Jul 25, 2025
Apr 21, 2025A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER (SHOE) TACK WELED PROPERLY SECURE BY USING APPROPRIATE NUTS AND BOLTS AT NORTH EXTERIOR WALLJul 25, 2025
Dec 6, 2023BApt 3 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... (APPROXIMATELY 24 SQ.FT) AT THE WEST WALL AND THE CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJan 10, 2024
Nov 8, 2023C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE MISSING VESTIBULE DOORS (VESTIBULE TO 1ST STY PUBLIC HALL)Nov 22, 2023
Jun 2, 2023B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 6 SQ.FT AT THE NORTH WALL AND APPROX 5 SQ.FT AT EAST WALL AT PUBLIC HALL STAIRS, 2nd STORY ORIGINAL VIOLATION 15694832 ISSUED 01-FEB-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) oJul 7, 2023
Feb 10, 2023BApt 12 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 6 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 12, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 15420582 ISSUED 12-OCT-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(Mar 17, 2023
Oct 19, 2022BApt 15 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 15, 4th STORY, 1st APARTMENT FROM WEST AT NORTHNov 23, 2022
Oct 14, 2022B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES .....TREE BRANCHES OBSTRUCTING SCUTTLE LADDER AT BUILDING NORTH AT FIRE ESCAPENov 18, 2022
Oct 13, 2022CApt 15 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 15, 4th STORY, 1st APARTMENT FROM WEST AT NORTHNov 8, 2022
Oct 13, 2022CApt 15 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 15, 4th STORY, 1st APARTMENT FROM WEST AT NORTHNov 8, 2022
Feb 8, 2022BApt 18 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... WEST WALL AROUND WINDOW FRAME (APPROX 12 SQ.FT.) IN THE BATHROOM LOCATED AT APT 18, 5th STORY, 4th APARTMENT FROM WEST AT NORTHMar 15, 2022
Jan 31, 2022BApt 18 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WINDOW FRAME APPROX 10 SQ. FT IN THE BATHROOM LOCATED AT APT 18, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTMar 7, 2022
Mar 31, 2021CApt 9 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH, EAST, WEST AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 9, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 13991009 ISSUED 19-JAN-21 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §27Apr 26, 2021

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 11:04 PM ET. BBL 2022660005.

Look up another building