Brooklyn · Block 5825 · Lot 1 · 11220

260 65 Street

31 floors · 420 apartments · 398,660 sq ft · built 1971 · class D4 · owner of record: Bayridge Air Rights Inc

158open violations
$2,400ECB/OATH penalties owed
23HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $42,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 118 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 398,660 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 797 days
Next cycle year 2028
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5825). Agency page

Dec 31, 2035
in 3353 days
Next due 2035
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-23 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (9) · $2,400 owed
IssuedViolationHearingBalance
Jul 8, 2026Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED INSTALLED AT ALL PERIMETER EXPOSURES BUT WAS NOT PROPERLY MAINTAINED. PORTIONS OF THE SIDEWALK SHED PARAPET WERE COLLAPSED AND MISSING AT EXP# 2, CREATING A HAZARDO
#39556294L
Sep 16, 2026
IN VIOLATION
$2,400
Dec 7, 2024Construction CLASS - 1
AC 28-323.8 AND RCNY 103-13(5). FAILURE TO SECURE PUBLIC SAFETY AND/ORMAKE THE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISION OF THE ADMINISTRATIVE CODE AFTER UNSAFE FILED BY QPSI. AS NOTED AT
#35689112P
Apr 9, 2026
IN VIOLATION
$0
Nov 7, 2024Cranes and Derricks CLASS - 2
AT TIME OF INSPECTION OF 31 STORY BUILDING EXTERIOR WORK OBSERVED. SUSPENDED SCAFFOLD IN PLACE AT EXPOSURE #2 AND #4. UPON RESEARCH NO NOTIFICATION EVIDENCE WAS FOUND PRIOR TO THE INITIAL INSTALLATION OF OUTRIG
#39534193P
Nov 10, 2025
ADMIT/IN-VIO
$0
Apr 16, 2024Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE & APPURTENANCES.AT TIME OF INSPECTION OBSERVED BULGING WALL/LEANING BRICK FACADE AT EXP #1 NORTH EXPOSURE.THIS BULDING WALLING CONTINUES UP THE WALL TO ROOF.AT EXP#
#35682380J
Oct 21, 2024
IN VIOLATION
$0
Apr 16, 2024Construction CLASS - 1
FAILURE TO OBEY VACATE ORDER FROM THE COMMISSIONER AS PER 28-207.4.AT TIME OF INSPECTION OBSERVED MULTIPLE PEOPLE STAND ON BALCONIES THAT WERE VACATED STILL VACATE ORDER HAS NOT BEEN LIFTED.FAILURE TO OBEY VACA
#35682052K
Apr 21, 2025
IN VIOLATION
$0
Apr 16, 2024Construction CLASS - 1
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTED:AT TIME OF INSPECTION OBSERVED DOB VIO #030222CFA31002MB ISSUED MARCH 2, 2022 DUE TO BRICK SECTION BULGING AT EXP #4 ISSUED TO PERFORM 100 % HANDS ON BRICK FACA
#35682381L
Oct 21, 2024
IN VIOLATION
$0
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE CYCLE 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #910062. REMEDY: FILE ACCEPTABLE REPORT.
#37026732L
May 1, 2024
IN VIOLATION
$0
Mar 2, 2022Construction CLASS - 1
FAILURE TO MAINTAIN BLDG EXTERIOR WALLS OR APPURTENANCES.NOTE:ATOI,OBSERVED SEVERELY BULGING BRICK MASONRY B/W 16&17FL (APRX10'X5')@EXP4W ELEVATION WHERE NO SAFETY MEASURES BELOW.PROVIDE SAFETY MEASURES&REPAIR
#35647435Y
Feb 2, 2023
IN VIOLATION
$0
Mar 2, 2022Construction CLASS - 1
FAILURE TO PROVIDE SWS WHERE REQUIRED NOTE:ATOI,OBSERVED THAT NO SAFETY OVERHEAD PROTECTION IN PLACE ON EXP4W ELEVATION TO PROTECT PUBLIC FROM UNSAFE CONDITION OBSERVED ON FACADE.PROVIDE SWS WHERE REQUIRED
#35647436X
Feb 2, 2023
IN VIOLATION
$0
DOB (20)
IssuedViolationStatus
Oct 8, 2026CONSTRUCTION
DUE TO THE WITHDRAWAL OF THE APPLICANT OF RECORD THE BOROUGH COMMISSIONERS OFFICE HAS ORDERED ALL WORK UNDER JOB B01166532-I1 TO STOP WORK IMMEDIATELY AND TO MAKE SITE SAFE AS PER SECTION 28-104.8.3
#26-02370
DOB VIOLATION - ACTIVE
Sep 17, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A BUILDING IN A CODE COMPLIANT MANNER NOTED ON EXP1 NORTH ELEV & EXP3 SOUTH ELEV,OBSERVED CRACKS AND SPALLIN G IN BALCONY SLABS,DAMAGED,SPALLING MORTAR JOINTS IN BRICK WORK.EXP2 E AST ELEV:CRACKS AND SPALLING IN BRICK WORK AND MORTAR JOINTS.EXP4 WEST ELEV:OBSERVED MIS
#SR1001RF
DOB VIOLATION - ACTIVE
Jun 11, 2026CONSTRUCTION
BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDERPERMIT#B01166532-I1 ON 11/13/25 APPLICANT WITHDRAWAL.
#26-01527
DOB VIOLATION - ACTIVE
Dec 16, 2025CONSTRUCTION
FAILURE TO MAINTAIN BLDG IN SAFE CONDITION.PRKNG STRUCT W/PRECAST DOUBLE TEE PLANKS@DECK SUPPORTD BY PRECAST BEAMS,COLUMNS,X-BRACES DOWN TO LIRR UNDERPASS BELOW.PRECAST CONC BEAMS,COLUMNS,XBRACES.IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER 342075 9051425FEU31003PN)DATED 5/14/2025
#FEU31001PN
DOB VIOLATION - ACTIVE
Dec 11, 2025CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED OPEN SECTIONS OF MASONRY BRICK WORK ON EXPOSURE 2 AND 4. REMEDY REPAIR AND OR REPLACE
#SR31001XN
DOB VIOLATION - ACTIVE
May 14, 2025CONSTRUCTION
FAILURE TO MAINTAIN BLDG IN SAFE CONDITION.PRECAST PARKING STRUCT W/ DOUBLE TEE PLANKS, CONE BEAMS,COLUMNS,&X-BRACES DOWN TO LIRR UNDERPASS BELOW.PRECAST CONE BEAMS,CULS,X-BRACES SEVERELY DETERIORATED.OWNR TO RTAIN NYSPE TO EVAL ENT PRKNG STRCTRE&FILE RPAIR DWGS W/DOB PERM RPAIRS TO STRT UNDR PRMT B
#FEU31002PN
DOB VIOLATION - ACTIVE
May 14, 2025CONSTRUCTION
EMERGENCY WORK ORDER.PRECAST PARKING LOT DOUBLE TEE PLANKS@DECK SUPPORTD BY PRECAST BEAMS,COLUMS,&X'BRACNG EXTENDNG DOWN TO THE LIRR UNDERPASS BELOW.BRACE WAS PRTLLY DTACHD/CRCKD.OWNR TO RTAIN NYSPE&GC TO IMMED SHORE PRKNG STRCTRE,AS REQ'D FILE JOB W/IN 2 DAYS OF WRK (B01166532 ALREADY FILED)
#FEU31001PN
DOB VIOLATION - ACTIVE
Mar 5, 2025FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00205
DOB VIOLATION - ACTIVE
Dec 11, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00572
DOB VIOLATION - ACTIVE
Dec 7, 2024CONSTRUCTION
PARTIAL VACATE ORDER. ONE FLOOR LEVEL PARKING GARAGE ADJACENT TO 30 STORIES BLDG SIGNIFICANT DETERIORATION OF PRECAST CONCRETE FRAMING ELEMENTS & FAILURE OF PRECAST CONCRETE ELE CONNECTION W/ADEQUATE SAFET MEAS.THESE COND MADE ENTIRE PARKING GARAGE STRUCTURE (ONE FL LVL UNABL TO BE OCCUPIED.REMEDY:V
#FA1002AE
DOB VIOLATION - ACTIVE
Aug 7, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00079
DOB VIOLATION - ACTIVE
Jun 2, 2022HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#910299
DOB VIOLATION - ACTIVE
Mar 3, 2022CONSTRUCTION
PARTIAL VACATE ORDER AS OBSERVED BY FACADE INSPECOTE ON 03/02/2022 THERE ARE BULGING BRICKS ON EXPOSURE #4, WEST ELEVATION. DUE TO THIS CONDITION, APT #14M,14N,15M,15N,16M,16N-EXTRA ROOM ARE TO BE VACATED LOCKING DEVICES ARE TO BE INSTALLED TO RESTRICT TENANT ACCESS. REMEDY: VACATE EXTRA ROOMS AT AP
#FA31001MB
DOB VIOLATION - ACTIVE
Mar 3, 2022CONSTRUCTION
PARTIAL VACATE ORDER AS OBSERVED BY FACADE INSPECTOR ON 03/02/2022 THERE ARE CRACKED-SPALLED BALCONY SLABS ON BOTH EXP 1 NORTH ELEVATION AND EXPOSURE 3 SOUTH ELEVATION. DUE TO THESE CONDITIONS ENTIRE BALCONY LINES ON BOTH EXP 1 & 3 ARE TO BE VACATED.LOCKING DEVICES ARE TO BE INSTALLED TO RESTRICT TE
#FA31002MB
DOB VIOLATION - ACTIVE
Mar 2, 2022CONSTRUCTION
AS PER UNSAFE CONDITIONS OBSERVED ON FACADE. REMEDY: OWNER TO IMMED RETAIN A NYS LIC PROF TO PERFORM A 100% HANDS ON INSPECTION ON ALL BALCONIES WITH HOLDING MECHANISM AT BOTH EXP#1(NORTH ELEVATION)AND EXP#3(SOUTH ELEVATION)AND PROVIDE INSPECTION REPORT. REPAIR PLANS AND PROPOSAL SUBMITTED TO DOB FA
#FA31003MB
DOB VIOLATION - ACTIVE
Mar 2, 2022CONSTRUCTION
AS PER CONDITIONS OBSERVED AT EXP4 WEST ELEVATION, BULGING BRICK SECTION BETWEEN 16TH AND 17TH FLOORS. REMEDY: OWNER TO IMMED RETAIN A NYS LIC PROF TO PERFORM A 100% HANDS ON INSPECTION ON ALL BRICKWORK WITH HOLDING MECHANISM OF ALL EXPOSURES AND PROVIDE INSPECTION REPORT, REPAIR PLANS AND PROPOSAL
#FA31002MB
DOB VIOLATION - ACTIVE
Mar 2, 2022CONSTRUCTION
EMERGENCY WORK ORDER TO PROVIDE SAFETY OVERHEAD PROTECTION. TAKE AND PROVIDE SAFETY MEASURES TO SECURE PUBLIC SAFETY DIE TO BULGING BRICKS BETWEEN 16TH AND 17TH FLOORS ON EXP4 WEST ELEVATION. REMEDY: IMMED PROVIDE SIDEWALK SHED PROTECTION ON ALL EXPOSURES TO PROTECT PUBLIC SAFETY
#FA31001MB
DOB VIOLATION - ACTIVE
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#01193
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2102694
DOB VIOLATION - ACTIVE
Aug 8, 2002LOCAL LAW 11/98 - FACADE

#NRF53392
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Mar 5, 2025AEUHAZ FTC-AEU-HAZ
Active
Mar 5, 2025Parking Structures FTC-PS-UNSAFE
Unsafe report of parking structures filed
Active
Dec 11, 2024AEUHAZ FTC-AEU-HAZ
Active
Aug 7, 2024AEUHAZ FTC-AEU-HAZ
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Jun 2, 2022Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
HPD (121) · C 23 · B 55 · A 43
IssuedClassViolationCorrect by
Oct 19, 2026BApt 30N · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 30N, 30th STORY, 1st APARTMENT FROM WEST AT NORTHNov 23, 2026
Oct 19, 2026BApt 30N · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 30N, 30th STORY, 1st APARTMENT FROM WEST AT NORTHNov 23, 2026
Oct 19, 2026CApt 30N · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 30N, 30th STORY, 1st APARTMENT FROM WEST AT NORTHNov 14, 2026
Oct 13, 2026CApt 24K · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 24K, 24th STORY, 2nd APARTMENT FROM WEST AT NORTHOct 10, 2026
Oct 13, 2026C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED TO BOILER ROOM AT BASEMENTOct 19, 2026
Oct 1, 2026CApt 30K · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 30K, 30th STORY, 2nd APARTMENT FROM WEST AT NORTHOct 1, 2026
Aug 14, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMANov 17, 2026
Aug 14, 2026A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD.Nov 17, 2026
Jul 21, 2026A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYOct 24, 2026
Jul 21, 2026BApt 24A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING, ,GROUTS JOINTS OF THE CERAMIC TILES AT NORTH, EAST AND SOUTH WALLS AROUND BATHTUB, IN THE BATHROOM LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTAug 25, 2026
Jul 21, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMAOct 24, 2026
Jul 21, 2026C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HINGES DOOR CLOSER INSTALLED ON SOUTH ENTRANCE DOOR TO LAUNDRY ROOM, AT PUBLIC HALL AT EAST , 1st STORYAug 4, 2026
Jul 21, 2026AApt 24A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT THE CEILING AND ALL WALLS, IN THE ENTIRE APARTMENT LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTOct 24, 2026
Jul 21, 2026AApt 24A · § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE VISIBLE MOLD AT CAULKING, GROUTS JOINTS OF THE CERAMIC TILES AT NORTH AND EAST WALLS AROUND BATHTUB, IN THE BATHROOM LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTOct 24, 2026
Jul 21, 2026BApt 24A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE METAL APARTMENT DOOR, IN THE ENTRANCE LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTAug 25, 2026
Jul 21, 2026BApt 24A · § 27-2005 HMC: REFIT METAL DOOR FRAME AT THE APARTMENT DOOR IN THE ENTRANCE LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTAug 25, 2026
Jul 21, 2026CApt 24A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES SPRINGS, IN THE ENTRANCE LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTAug 4, 2026
Jul 8, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMAOct 11, 2026
Jul 8, 2026A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYOct 11, 2026
Jul 8, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES SPRINGS AT EAST ENTRANCE TO FIRE STAIRCASE , AT PUBLIC HALL AT NORTHWEST , 1st STORYJul 22, 2026
Jul 8, 2026C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CHAIR SETTED AND OBSTRUCTED SOUTH ENTRANCE DOOR TO LAUNDRY ROOM, AT PUBLIC HALL AT EAST , 1st STORYJul 22, 2026
Jul 26, 2024CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 14th STORYAug 21, 2024
Apr 3, 2024C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WOOD WEDGE JAMMED ENTRANCE DOOR TO LAUNDRY ROOM, IN EAST SECTIONS, AT PUBLIC HALL, 1st STORYApr 17, 2024
Apr 3, 2024BApt 8J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 8J, 9th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''WEST''May 8, 2024
Apr 3, 2024CApt 8J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 8J, 9th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''WEST''Apr 29, 2024
Apr 3, 2024AApt 8J · § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE AT NORTH, WEST AND SOUTH WALLS AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 8J, 9th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''WEST''Jul 7, 2024
Apr 3, 2024A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYJul 7, 2024
Apr 3, 2024CApt 8J · § 27-2005, 2007 HMC: REMOVE THE ILLEGAL DOUBLE CYLINDER KEY OPERATED LOCKING DEVICE AT DOOR OF APT 8J. IN THE ENTRANCE LOCATED AT APT 8J, 9th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''WEST''Apr 9, 2024
Jan 25, 2024BApt 28C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 9 SQUARE FEET AT WOOD FLOOR TILES, IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 28C, 29th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16251513 ISSUED 26-SEP-23 HAS BEEN UPGRADED TO Feb 29, 2024
Sep 27, 2023CApt 28C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 28C, 29th STORY, 1st APARTMENT FROM NORTH AT EASTOct 23, 2023
Sep 27, 2023B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE PUSH BAR AT ENTRANCE DOOR TO BUILDING 1ST FROM EAST AT SOUTH, AT PUBLIC HALL, 1st STORYNov 1, 2023
Sep 27, 2023CApt 28C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 28C, 29th STORY, 1st APARTMENT FROM NORTH AT EASTOct 11, 2023
Sep 27, 2023C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING [ GARBAGE CAN OBSTRUCTED ENTRANCE DOOR TO LAUNDRY ROOM ], AT PUBLIC HALL, 1st STORYOct 11, 2023
Sep 27, 2023A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYDec 31, 2023
Sep 27, 2023BApt 28C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR TILES, IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 28C, 29th STORY, 1st APARTMENT FROM NORTH AT EASTNov 1, 2023
May 25, 2023A§ 27-2005 HMC: REFIT LAUNDRY ROOM DOOR AT PUBLIC HALL, 1st STORY, SECTION ''east''Aug 28, 2023
May 25, 2023A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY, SECTION ''east''Aug 28, 2023
May 12, 2023BApt 14A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE BATHROOM LOCATED AT APT 14A, 14th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 15657029 ISSUED 11-JAN-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).Jun 16, 2023
Mar 21, 2023BApt 14A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 1 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 14A, 14th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 15554797 ISSUED 19-NOV-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3Apr 25, 2023
Mar 13, 2023AApt 14A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 14A, 14th STORY, 3rd APARTMENT FROM SOUTH AT WESTJun 16, 2023
Mar 13, 2023BApt 14A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 14A, 14th STORY, 3rd APARTMENT FROM SOUTH AT WESTApr 17, 2023
Mar 8, 2023A§ 27-2005 ADM CODE REFIT DOOR LEADING TO SOUTH YARD AT PUBLIC HALL, 1st STORY, SECTION ''west''Jun 11, 2023
Mar 3, 2023BApt 14A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... ,5 SQ. FT. AT CEILING IN THE BATHROOM LOCATED AT APT 14A, 14th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 15475905 ISSUED 02-NOV-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)Apr 7, 2023
Feb 21, 2023CApt 3M · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR ( TRIP HAZARD) APPROXIMATELY 5SQ FEET IN THE 1st ROOM FROM EAST LOCATED AT APT 3M, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WESTFeb 27, 2023
Feb 21, 2023CApt 3M · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3M, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WESTMar 19, 2023
Jan 24, 2023A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYApr 29, 2023
Jan 24, 2023C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING AT FIRE DOOR LEADING TO LAUNDRY ROOM AT SOUTH SECTION EAST AT PUBLIC HALL, 1st STORYJan 30, 2023
Jan 24, 2023C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING AT FIRE DOOR LEADING TO COMPACTOR ROOM AT NORTH SECTION EAST AT PUBLIC HALL, 1st STORYJan 30, 2023
Jan 24, 2023A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR [ MISSING FRAME ] AT PUBLIC HALL, 1st STORYApr 29, 2023
Jan 24, 2023A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX [ MISSING NOTICE ] AT PUBLIC HALL, 1st STORYApr 29, 2023
Jan 24, 2023A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYApr 29, 2023
Jan 12, 2023CApt 14A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 14A, 14th STORY, 1st APARTMENT FROM EAST AT SOUTHJan 18, 2023
Jan 12, 2023BApt 14A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 14A, 14th STORY, 1st APARTMENT FROM EAST AT SOUTHFeb 16, 2023
Dec 20, 2022BApt 9M · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 9M, 9th STORY, 2nd APARTMENT FROM SOUTH AT WESTJan 24, 2023
Dec 20, 2022BApt 9M · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 9M, 9th STORY, 2nd APARTMENT FROM SOUTH AT WESTJan 24, 2023
Dec 20, 2022A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT WALL AT PUBLIC HALL, 1st STORYMar 25, 2023
Nov 21, 2022AApt 14A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 14A, 14th STORY, 1st APARTMENT FROM SOUTH AT WESTFeb 24, 2023
Nov 21, 2022BApt 14A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 14A, 14th STORY, 1st APARTMENT FROM SOUTH AT WESTDec 26, 2022
Nov 3, 2022BApt 14A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ,AT CEILING IN THE BATHROOM LOCATED AT APT 14A, 14th STORY, 1st APARTMENT FROM EAST AT SOUTHDec 8, 2022
Nov 2, 2022A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYFeb 5, 2023

Showing 60 of 121. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Oct 19, 2026HPD B§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 30N, 30th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 19, 2026HPD B§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 30N, 30th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 19, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 30N, 30th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 13, 2026HPD C§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 24K, 24th STORY, 2nd APARTMENT FROM WEST AT NORTHOpen
Oct 13, 2026HPD C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED TO BOILER ROOM AT BASEMENTOpen
Oct 8, 2026DOBCONSTRUCTION: DUE TO THE WITHDRAWAL OF THE APPLICANT OF RECORD THE BOROUGH COMMISSIONERS OFFICE HAS ORDERED ALL WORK UNDER JOB B01166532-I1 TO STOP WORK IMMEDIATELY AND TO MAKE SITE SAFE AS PER SECTION 28-104.8.3Open
Oct 1, 2026HPD C§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 30K, 30th STORY, 2nd APARTMENT FROM WEST AT NORTHOpen
Sep 17, 2026DOBCONSTRUCTION: FAILURE TO MAINTAIN BUILDING IN A BUILDING IN A CODE COMPLIANT MANNER NOTED ON EXP1 NORTH ELEV & EXP3 SOUTH ELEV,OBSERVED CRACKS AND SPALLIN G IN BALCONY SLABS,DAMAGED,SPALLING MORTAR JOINTS IN BRICK WORK.EXP2 E AST ELEV:CRACKS AND SPALLING IN BRICK WORK AND MORTAR JOINTS.EXP4 WEST ELEV:OBSERVED MISOpen
Aug 14, 2026HPD A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMAOpen
Aug 14, 2026HPD A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD.Open
Jul 21, 2026HPD A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYOpen
Jul 21, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING, ,GROUTS JOINTS OF THE CERAMIC TILES AT NORTH, EAST AND SOUTH WALLS AROUND BATHTUB, IN THE BATHROOM LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTOpen
Jul 21, 2026HPD A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMAOpen
Jul 21, 2026HPD C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HINGES DOOR CLOSER INSTALLED ON SOUTH ENTRANCE DOOR TO LAUNDRY ROOM, AT PUBLIC HALL AT EAST , 1st STORYOpen
Jul 21, 2026HPD A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT THE CEILING AND ALL WALLS, IN THE ENTIRE APARTMENT LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTOpen
Jul 21, 2026HPD A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE VISIBLE MOLD AT CAULKING, GROUTS JOINTS OF THE CERAMIC TILES AT NORTH AND EAST WALLS AROUND BATHTUB, IN THE BATHROOM LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTOpen
Jul 21, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE METAL APARTMENT DOOR, IN THE ENTRANCE LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTOpen
Jul 21, 2026HPD B§ 27-2005 HMC: REFIT METAL DOOR FRAME AT THE APARTMENT DOOR IN THE ENTRANCE LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTOpen
Jul 21, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES SPRINGS, IN THE ENTRANCE LOCATED AT APT 24A, 25th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EASTOpen
Jul 8, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED INSTALLED AT ALL PERIMETER EXPOSURES BUT WAS NOT PROPERLY MAINTAINED. PORTIONS OF THE SIDEWALK SHED PARAPET WERE COLLAPSED AND MISSING AT EXP# 2, CREATING A HAZARDOOpen
Jul 8, 2026HPD A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMAOpen
Jul 8, 2026HPD A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYOpen
Jul 8, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES SPRINGS AT EAST ENTRANCE TO FIRE STAIRCASE , AT PUBLIC HALL AT NORTHWEST , 1st STORYOpen
Jul 8, 2026HPD C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CHAIR SETTED AND OBSTRUCTED SOUTH ENTRANCE DOOR TO LAUNDRY ROOM, AT PUBLIC HALL AT EAST , 1st STORYOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 12:56 AM ET. BBL 3058250001.