2 floors · 2 apartments · 4,245 sq ft · built 1899 · class B2 · owner of record: 26 Jefferson Ave Partners Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 306 days | Required only if the owner doesn't live there |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 27, 2026 | Unknown CLASS - 2 AT THE TIME OF INSPECTION, NO CONSTRUCTION ACTIVITY WAS OBSERVED. HOWEVER, MATERIALS WERE STORED ON THE SIDEWALK ABOVE THE CODE-ALLOWED LIMIT. THE EXCESSIVE MATERIAL STORAGE OBSTRUCTS THE SIDEWALK AND CREATES A #39559821H | Dec 2, 2026 PENDING | $2,500 |
| Sep 27, 2026 | Unknown CLASS - 2 AT THE TIME OF INSPECTION, NO CONSTRUCTION ACTIVITY WAS OBSERVED. A SIDEWALK SHED INSTALLED AT EXP 1; HOWEVER, A REVIEW OF THE RECORDS INDICATES THAT THE ASSOCIATED PERMIT EXPIRED ON 08/02/2026. THE CONTINUED P #39559815L | Dec 2, 2026 PENDING | $1,250 |
| Jul 17, 2026 | Construction CLASS - 2 ACTIVE 4 STORY ALTERATION. NOTED FENCE AT EXPO 1 IS IN DISREPAIR. OBSERVED DAMAGE/HOLES IN FENCE WITH PEELING WOOD THAT COULD POSSIBLY HURT PEDESTRIANS WALKING BY. FENCE NOT MAINTAINED AS PER 3307.7.7MAINTAIN C #39556748R | Sep 23, 2026 DEFAULT | $1,030 |
| Jul 17, 2026 | Unknown CLASS - 2 3309.10 OBSERVED 4STORY ALTERATION IN PROGRESS. OBSERVED NO ROOF PROTECTION ON NEIGHBORS AWNING AT EXPOSURE 4. WORK HAD REACHED THE 4TH FLOOR AND WAS WELL ABOVE 48INCHES ABOVE NEIGHBORS AWNING. CONSTRUCTION CON #39556747P | Sep 23, 2026 DEFAULT | $2,530 |
| Jul 17, 2026 | Unknown CLASS - 2 ACTIVE 4STORY ALT. OBSERVED SCAFFOLDS THRUOUT SITE UNMAINTAINED AS PER 3314/3314.8. SUPPORTED SCAFFOLD @EXPO1 NOT FULLY NETTED/ENCLOSED, OBSERVED MISSING TOEBOARDS & GUARDRAILS CREATE UNSAFE CONDITIONS, DEBRIS #39556811K | Sep 23, 2026 DEFAULT | $2,530 |
| Jul 17, 2026 | Construction CLASS - 2 3301.6/3301.7 ACTIVE 4STORY ALT. NOTED MAKESHIFT TEMPORARY STAIRS WERE SEEN ONSITE AS MEANS OF EGRESS TO ACCESS UPPER FLOORS WITH DAMAGE ON SEVERAL OF THE STAIR TREADS & FELT UNSECURE/UNSTABLE AS WEIGHT WAS PRE #39556812M | Sep 23, 2026 DEFAULT | $1,280 |
| Feb 19, 2026 | Construction CLASS - 2 ECB VIOLATION ISSUED FOR CONST. FENCE AT PREMISES WITHOUT A RENEWED PERMIT. OBSERVED FENCE AT EXPOSURE #1 OF PREMISES WITH NO ACTIVE FENCE PERMIT. WORK FILED UNDER PERMIT # B00780977-II- GC. WITH A FENCE PERMIT #39177839M | May 6, 2026 DEFAULT | $3,125 |
| Sep 24, 2025 | Construction CLASS - 2 MISSING OVERHEAD PROTECTION. AT TIME OF INSPECTION OF AN OPEN SITE OBSERVED NO OVERHEAD PROTECTION AT EXP# 4 FOR THE ADJOINING PROPERTY CREATING A POTENTIAL SAFETY HAZARDOUS CONDITION. STOP ALL WORK 15FT BACK E #39545253L | Apr 16, 2027 | $5,000 |
| Sep 24, 2025 | Construction CLASS - 1 AT TIME OF MY INSPECTION, OPEN SITE OBSERVED NO GUARDRAIL SYSTEM INSTALLED AT UNPROTECTED PERIMETER SECOND FLOOR EXP# 2 3 4. STOP ALL WORK 15FT BACK AT LEADING EDGE SECOND FLOOR EXP# 2 3 4. PROVIDE GUARDRAIL SY #39545254N | Apr 16, 2027 | $12,500 |
| Sep 19, 2025 | Construction CLASS - 1 STOP WORK ORDER ISSUED ON 09/18/25 UNDER COMPLAIN # 3A29781. SWO ISSUED FOR FAILURE TO PROVIDE INSPECTOR ACCESS ONTO JOBSITE & FAILURE TO SAFEGUARD PUBLIC & PROPERTY. RESPONDING TO A COMPLAINT OBSERVED SEVERA #39545092J | Apr 16, 2027 PENDING | $25,000 |
| Sep 19, 2025 | Unknown CLASS - 2 3314.1 OBSERVED: WORKER ACTIVELY WORKING ON SUPPORTED SCAFFOLD BUILT IN UNSAFE MANNER AT THE REAR OF THE BUILDING EXPOSURE, NOTICE WORKER STANDING ON SCAFFOLD THAT IS NOT FULLY PLANKED, WITH NO GUARDRAIL AND NO #39545100K | Apr 16, 2027 PENDING | $10,000 |
| Sep 19, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED: UPON ENTERING NEIGHBORING PROPERTY EVIDENCE OF FALLING DEBRIS (CEMENT) & PROTRUDING OBJECTS IN BACKYARD & BUILDING COURT YARD WITH NO OVERHEAD PROTECTION / SAFETY MEASURES IN P #39545093L | Apr 16, 2027 | $5,000 |
| Sep 18, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED: UPON ENTERING NEIGHBOR PROPERTY EVIDENCE OF FALLING DEBRIS (CEMENT) & PROTRUDING OBJECTS IN NEIGHBOR BACKYARD WITH NO OVERHEAD PROTECTION / SAFETY MEASURES IN PLACE AS REQUIRED S #39545042L | Apr 16, 2027 PENDING | $10,000 |
| Sep 18, 2025 | Construction CLASS - 2 AT THE TIME OF INSPECTION, UPON HEARING WORKERS IN THE BUILDING CALLED OUT & KNOCKED SEVERAL TIMES, OBSERVED WORKER EXISTING JOBSITE APPROACHED HIM TO GAIN ACCESS, HE DENIED ME & CONTINUING TO STAND OUTSIDE PRE #39545043N | Apr 16, 2027 PENDING | $10,000 |
| Sep 18, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION OF A 4 STORY APPROXIMATELY 44 FEET IN HEIGHT AT 3RD FLOOR LEVEL (30 FEET) AND APPROXIMATELY 10 FEET SETBACK FROM SIDEWALK, PATHWAY AND WALKWAY AT EXPOSURE 1. I OBSERVED THAT THERE WERE NO #39545041J | Apr 16, 2027 PENDING | $25,000 |
| Dec 16, 2024 | Construction CLASS - 1 ATOI OBSERVED CHIMNEY SYSTEM AT INTERIOR & EXTERIOR OF EXPO-4/ROOF DEMOLISHED WITHOUT A PERMIT. DEMO PERFORMED AT ADJOINING PARTY WALL SHARED WITH OCCUPIED 1-FAMILY HOUSE. WORK PERFORMED WITH NO DRAWINGS, MEANS #39133011H | Dec 21, 2026 DEFAULT | $25,000 |
| Dec 16, 2024 | Construction CLASS - 2 ATOI OBSERVED TEMPORARY ELECTRICAL LIGHTING INSTALLED WITHOUT A PERMIT. YELLOW ELECTRICAL WIRING & STRING LIGHTS OBSERVED ATTACHED TO CEILING JOISTS THROUGHOUT THE INTERIOR OF THE 1ST FLR & 2ND FLR AT THE REAR #39133016R | Dec 17, 2026 DEFAULT | $3,125 |
| Dec 16, 2024 | Construction CLASS - 1 ATOI OBSERVED TEMP WOOD STRUCTURAL SHORING OF 2ND FLR OVERHEAD LOAD AT FRONT PORCH 1ST FLR EXPO1. EXPO-3 FACADE & BLDG ENVELOPE STRUCTURAL ELEMENTS OF ALL DOOR FRAMES, WINDOW LENTILS, OPENINGS DEMOLISHED FROM C #39133012J | Dec 21, 2026 DEFAULT | $6,250 |
| Dec 16, 2024 | Construction CLASS - 1 ATOI OBSERVED ALTERATIONS/ENLARGEMENT OF EXISTING FOUNDATION PERFORMED AT EXTERIOR EXPO-3 REAR YARD WITH APPROX 30FTX20FT OF NEW CEMENT FOUNDATION, CMU BLOCK IN PLACE, WITH NEW RETAINING WALLS POURED FOR HORIZO #39133013L | Dec 21, 2026 DEFAULT | $6,250 |
| Dec 16, 2024 | Construction CLASS - 1 ATOI OBSERVED EXCAVATION OF APPROX 35FT X 25FT OF EARTH AT A DEPTH OF APPROX 5 FT PERFORMED AT EXTERIOR REAR YARD ADJACENT TO EXPOSURE 3 FOR THE ADDITION OF AN UNPERMITTED HORIZONTAL EXTENSION OF EXISTING BLDG #39133014N | Dec 21, 2026 DEFAULT | $12,500 |
| Dec 16, 2024 | Construction CLASS - 1 ATOI OBSERVED A FAILURE TO SAFEGUARD CONSTRUCTION OPERATIONS IMPACTING OCCUPIED ADJOINING PROPERTIES & OCCUPANTS OF ADJOINING MULTIPLE DWELLING AT EXPO-2 & ADJOINING 1-FAMILY DWELLING AT EXPO-4. NO OVERHEAD PRO #39133018K | Dec 21, 2026 DEFAULT | $25,000 |
| Dec 16, 2024 | Construction CLASS - 2 UNSAFE UNPERMITTED MAKESHIFT CONSTRUCTION FENCE IN PLACE AT REAR YARD EXPO-2/3. APPROX 45 LINEAR FT OF PLYWOOD FENCE IN PLACE IMPROPERLY CONSTRUCTED & ANCHORED TO EXISTING CHAIN LINK FENCE OF ADJACENT OCCUPIED #39133015P | Dec 21, 2026 DEFAULT | $3,125 |
| Dec 2, 2024 | Construction CLASS - 2 JOBSITE CONSTRUCTION FENCE UNDER PERMIT #B00780977-S5-FN HAS EXPIRATION DATE 11/06/2023., RENEW PERMIT #39131704L | Dec 21, 2026 DEFAULT | $3,125 |
| Dec 2, 2024 | Construction CLASS - 2 JOBSITE FENCE HAS ENTRY DOORS OPEN AND NOT SECURED., COMPLY WITH CODE #39131703J | Dec 21, 2026 DEFAULT | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Dec 20, 2024 | CONSTRUCTION UNPERMITTED DEMOLITION,SHORING & FOUNDATION WORK TOOK PLACE. POTENTIAL HAZARDS OBSERVED ON SITE. REMEDY: RETAIN NYS REGISTERED PE TO SUBMIT STRUCTURAL STABILITY RPT WITH STABILIZATION RECOMMENDATIONS BY 12/27/24 #CE30301JT | DOB VIOLATION - ACTIVE |
| Aug 26, 2022 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED A HOLE IN THE PARTY WALL BETWEEN 24 JEFFERSON AVE AND 26 JEFFERSON AVE. AT SECOND STORY LEVEL, MISSING BRICKS, ABLE TO SEE THROUGH TO NEXT DOOR PROPERTY. #22-03086 | DOB VIOLATION - ACTIVE |
| Jun 7, 2022 | CONSTRUCTION AT TIME OF INSPECTION, OBSERVED AT EXPOSURE 1 FRONT OF PREMISES, INTERIOR COMPLETE GUT RENOVATION OF REMOVAL OF WALLS, FLOORS, CEILINGS, STAIRS, ELECTRICAL AND PLUMBING FIXTURES. NO PERMIT FILED WITH DOB. #22-01753 | DOB VIOLATION - ACTIVE |
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 27, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION, NO CONSTRUCTION ACTIVITY WAS OBSERVED. HOWEVER, MATERIALS WERE STORED ON THE SIDEWALK ABOVE THE CODE-ALLOWED LIMIT. THE EXCESSIVE MATERIAL STORAGE OBSTRUCTS THE SIDEWALK AND CREATES A | Open |
| Sep 27, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION, NO CONSTRUCTION ACTIVITY WAS OBSERVED. A SIDEWALK SHED INSTALLED AT EXP 1; HOWEVER, A REVIEW OF THE RECORDS INDICATES THAT THE ASSOCIATED PERMIT EXPIRED ON 08/02/2026. THE CONTINUED P | Open |
| Jul 17, 2026 | ECB | Construction: ACTIVE 4 STORY ALTERATION. NOTED FENCE AT EXPO 1 IS IN DISREPAIR. OBSERVED DAMAGE/HOLES IN FENCE WITH PEELING WOOD THAT COULD POSSIBLY HURT PEDESTRIANS WALKING BY. FENCE NOT MAINTAINED AS PER 3307.7.7MAINTAIN C | Closed |
| Jul 17, 2026 | ECB | Unknown: 3309.10 OBSERVED 4STORY ALTERATION IN PROGRESS. OBSERVED NO ROOF PROTECTION ON NEIGHBORS AWNING AT EXPOSURE 4. WORK HAD REACHED THE 4TH FLOOR AND WAS WELL ABOVE 48INCHES ABOVE NEIGHBORS AWNING. CONSTRUCTION CON | Closed |
| Jul 17, 2026 | ECB | Unknown: ACTIVE 4STORY ALT. OBSERVED SCAFFOLDS THRUOUT SITE UNMAINTAINED AS PER 3314/3314.8. SUPPORTED SCAFFOLD @EXPO1 NOT FULLY NETTED/ENCLOSED, OBSERVED MISSING TOEBOARDS & GUARDRAILS CREATE UNSAFE CONDITIONS, DEBRIS | Open |
| Jul 17, 2026 | ECB | Construction: 3301.6/3301.7 ACTIVE 4STORY ALT. NOTED MAKESHIFT TEMPORARY STAIRS WERE SEEN ONSITE AS MEANS OF EGRESS TO ACCESS UPPER FLOORS WITH DAMAGE ON SEVERAL OF THE STAIR TREADS & FELT UNSECURE/UNSTABLE AS WEIGHT WAS PRE | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 30, 2026, 10:42 PM ET. BBL 3019970019.