2 floors · 14,075 sq ft · built 1931 · class E1 · owner of record: North Henry Partners Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 51 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 782 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 8, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION OBSERVED: ACTIVE JOB SITE AT 3RD FLOOR LEVEL, STEEL COLUMN REACHED MORE THAN 40' HEIGHT APPROX. NO OVERHEAD PROTECTION FOR ADJOINING PROPERTIES AT EXPOSURE# 4 CREATING POTENTIAL SAFETY HAZ #39560412P | Dec 16, 2026 PENDING | $10,000 |
| Oct 8, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED: PROPOSED 4 STORY ALT. BUILDING AT 3RD FL. LEVEL. 10 FT. ABOVE ADJOINING PROPERTY. NO ROOF PROTECTION AT EXPOSURE# 4; CREATING AN UNSAFE HAZARDOUS CONDITION FOR ADJOINING OCCUPIED #39560411N | Dec 16, 2026 PENDING | $2,500 |
| Sep 29, 2026 | Unknown CLASS - 1 STOP ALL WORK UNDER #321184419. PRE-SHIFT MEETING LOG PROVIDED DOES NOT IDENTIFY SPECIFIC SAFETY CONCERNS/ RISKS ASSOCIATED WITH TASKS TO BE PERFORMED DURING THE SHIFT.MAINTAIN PRE-SHIFT MEETING LOGS WHICH INCL #39559981R | Dec 9, 2026 PENDING | $5,000 |
| Sep 29, 2026 | Construction CLASS - 2 OBSERVED STREET OPERATIONS/OCCUPANCY CONTRARY TO SITE SAFETY PLAN. NO ENCLOSURE USING YODOCK / JERSEY BARRIERS AROUND STAGING AREA AT EXPO 1. DUMPSTER/ MATERIAL RECEIVED PLACED ON STREET PRESENTING A HAZARD TO #39559982Z | Dec 9, 2026 PENDING | $1,250 |
| Jan 23, 2026 | Construction CLASS - 1 OBSERVED WORK CONTRARY TO PLANS-MISSING RAKERS(EXP#1,2,4)-MISSING HORIZONTAL BRACING(EXP#1/2 AND EXP#1/4)-MISSING BOLTS/NUTS ON RAKERS TO WALERS CONNECTION,,NO OPTICAL MONITORING PLAN PROVIDED AS PER PLAN-CREA #39549473L | Apr 1, 2026 IN VIOLATION | $2,500 |
| Jan 23, 2026 | Site Safety CLASS - 1 AT THE TIME OF MY INSPECTION-OBSERVED HORIZONTAL BRACING INSTALLED AT EXP#1,2,4 ON ADJ PROPERTY 1ST FLOOR LEVEL,AND FRONT EXP#1 BUILDING WALL-OBSERVED STRUCTURE INSTALLED AT EXP#1 ON JOISTS/POSTS-UPPON ASKING F #39549474N | Apr 1, 2026 IN VIOLATION | $2,500 |
| Jan 23, 2026 | Construction CLASS - 2 OBSERVED SIDEWALK SHED INSTALLED AT EXP #1 WITH NO 5 FEET EXTENSION PROVIDED AT CORNER OF EXP#1/2(BC 3307.6.3),ADDITIONALLY OBSERVED BENDED BRACE,BENDED POST-CREATING PEDESTRIAN SAFETY FOR FALLING OBJECTS/COLLA #39549475P | Apr 1, 2026 IN VIOLATION | $2,400 |
| Jan 23, 2026 | Site Safety CLASS - 1 UPON CHECKING CONSTRUCTION SUPERINTENDED LOG BOOK -LAST RECORDED ENTRY OF BEING ON SITE/CHECKING THE SITE WAS ON-12/30/25- AND WORK BEING CONDUCTED CONTINUOUSLY AFTER 12/30/25-AS PER CODE IF CS WONT BE ON SITE #39549476R | Oct 13, 2026 IN VIOLATION | $10,000 |
| May 28, 2025 | Unknown CLASS - 2 AT THE TIME OF INSPECTION ON A NON ACTIVE JOB SITE, I OBSERVED SIDEWALK SHED ON PREMISES UPON MY REVIEW THROUGH DOB NOW AND BIS PERMIT # B00878258-I1-SH WAS EXPIRED SINCE 05-22-2024 AND NO NEW PERMIT WAS IN SY #39540690R | Aug 6, 2025 IN VIOLATION | $1,250 |
| May 23, 2024 | Unknown CLASS - 2 ATOI OBSERVED SWS IN PLACE AT EXPOSURE 1 OF PROPERTY, APPROX. 110 LINEAR FT IN LENGTH. SEARCH OF DEPT RECORDS INDICATES SWS PERMIT EXPIRED AS OF 05/22/2024. (PERMIT# B00878258-I1-SH) PERMIT MUST BE RENEWED AS P #39115178K | Aug 7, 2024 DEFAULT | $3,125 |
| May 22, 2024 | Construction CLASS - 2 ATOI OBSERVED APPROX 110 LINEAR FT SWS IN PLACE AT EXP 1. VERTICAL SUPPORTS @ PEDESTRIAN SIDEWALK COMPROMISED DUE TO MULTIPLE CRACKED/DAMAGED MUDSILLS. SHED MISSING HI-VIZ MARKINGS & SAFETY MEASURES AT ADJACENT #39115042L | Aug 7, 2024 DEFAULT | $10,000 |
| May 22, 2024 | Construction CLASS - 2 ATOI OBSERVED APPROX. 110 LINER FEAT SWS IN PLACE AT EXPOSURE 1. PERMIT NOT POSTED ON SITE AS PER CODE 28-105.11. PERMIT # B00878259-I1-SH, POST/PROPERLY POST PERMIT #39115049Y | Aug 7, 2024 DEFAULT | $1,500 |
| May 18, 2022 | Construction CLASS - 2 TEMPORARY EQUIPMENT ONSITE(SWS)-EXPIRED PERMIT OBSERVED SIDEWALK SHED STILL UP AT EXPOSURE#1.TEMPORARY CONSTRUCTION EQUIPMENT REQUIRES A PERMIT AT ALL TIMES TO REMAIN INSTALLED.PERMIT IN DOBNOW#B00536365 EXPIRE #35586546K | Oct 12, 2022 DEFAULT | $6,250 |
| Issued | Violation | Status |
|---|---|---|
| May 8, 2026 | CONSTRUCTION FAILURE TO COMPLY COMMISSIONER'S ORDER CONTAINED IN VIOLATION 041526CE30101ML (CONTROL 376486) ISSUED 4/15/2026. REMEDY: COMPLY WITH AFOREMENTIONED COMMISSIONER'S ORDER. PROVIDE ALL REQUESTED DOCUMENTS #CE30101ML | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 8, 2026 | ECB | Unknown: AT TIME OF INSPECTION OBSERVED: ACTIVE JOB SITE AT 3RD FLOOR LEVEL, STEEL COLUMN REACHED MORE THAN 40' HEIGHT APPROX. NO OVERHEAD PROTECTION FOR ADJOINING PROPERTIES AT EXPOSURE# 4 CREATING POTENTIAL SAFETY HAZ | Open |
| Oct 8, 2026 | ECB | Unknown: AT TIME OF INSPECTION OBSERVED: PROPOSED 4 STORY ALT. BUILDING AT 3RD FL. LEVEL. 10 FT. ABOVE ADJOINING PROPERTY. NO ROOF PROTECTION AT EXPOSURE# 4; CREATING AN UNSAFE HAZARDOUS CONDITION FOR ADJOINING OCCUPIED | Open |
| Sep 29, 2026 | ECB | Unknown: STOP ALL WORK UNDER #321184419. PRE-SHIFT MEETING LOG PROVIDED DOES NOT IDENTIFY SPECIFIC SAFETY CONCERNS/ RISKS ASSOCIATED WITH TASKS TO BE PERFORMED DURING THE SHIFT.MAINTAIN PRE-SHIFT MEETING LOGS WHICH INCL | Open |
| Sep 29, 2026 | ECB | Construction: OBSERVED STREET OPERATIONS/OCCUPANCY CONTRARY TO SITE SAFETY PLAN. NO ENCLOSURE USING YODOCK / JERSEY BARRIERS AROUND STAGING AREA AT EXPO 1. DUMPSTER/ MATERIAL RECEIVED PLACED ON STREET PRESENTING A HAZARD TO | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 10, 2026, 3:01 PM ET. BBL 3026290025.