Brooklyn · Block 2629 · Lot 25 · 11222

259 North Henry Street

2 floors · 14,075 sq ft · built 1931 · class E1 · owner of record: North Henry Partners Llc

14open violations
$58,275ECB/OATH penalties owed
0HPD class C (immediately hazardous)
782dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 51 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 782 days
Next cycle year 2028

Open violations

ECB / OATH (13) · $58,275 owed
IssuedViolationHearingBalance
Oct 8, 2026Unknown CLASS - 1
AT TIME OF INSPECTION OBSERVED: ACTIVE JOB SITE AT 3RD FLOOR LEVEL, STEEL COLUMN REACHED MORE THAN 40' HEIGHT APPROX. NO OVERHEAD PROTECTION FOR ADJOINING PROPERTIES AT EXPOSURE# 4 CREATING POTENTIAL SAFETY HAZ
#39560412P
Dec 16, 2026
PENDING
$10,000
Oct 8, 2026Unknown CLASS - 2
AT TIME OF INSPECTION OBSERVED: PROPOSED 4 STORY ALT. BUILDING AT 3RD FL. LEVEL. 10 FT. ABOVE ADJOINING PROPERTY. NO ROOF PROTECTION AT EXPOSURE# 4; CREATING AN UNSAFE HAZARDOUS CONDITION FOR ADJOINING OCCUPIED
#39560411N
Dec 16, 2026
PENDING
$2,500
Sep 29, 2026Unknown CLASS - 1
STOP ALL WORK UNDER #321184419. PRE-SHIFT MEETING LOG PROVIDED DOES NOT IDENTIFY SPECIFIC SAFETY CONCERNS/ RISKS ASSOCIATED WITH TASKS TO BE PERFORMED DURING THE SHIFT.MAINTAIN PRE-SHIFT MEETING LOGS WHICH INCL
#39559981R
Dec 9, 2026
PENDING
$5,000
Sep 29, 2026Construction CLASS - 2
OBSERVED STREET OPERATIONS/OCCUPANCY CONTRARY TO SITE SAFETY PLAN. NO ENCLOSURE USING YODOCK / JERSEY BARRIERS AROUND STAGING AREA AT EXPO 1. DUMPSTER/ MATERIAL RECEIVED PLACED ON STREET PRESENTING A HAZARD TO
#39559982Z
Dec 9, 2026
PENDING
$1,250
Jan 23, 2026Construction CLASS - 1
OBSERVED WORK CONTRARY TO PLANS-MISSING RAKERS(EXP#1,2,4)-MISSING HORIZONTAL BRACING(EXP#1/2 AND EXP#1/4)-MISSING BOLTS/NUTS ON RAKERS TO WALERS CONNECTION,,NO OPTICAL MONITORING PLAN PROVIDED AS PER PLAN-CREA
#39549473L
Apr 1, 2026
IN VIOLATION
$2,500
Jan 23, 2026Site Safety CLASS - 1
AT THE TIME OF MY INSPECTION-OBSERVED HORIZONTAL BRACING INSTALLED AT EXP#1,2,4 ON ADJ PROPERTY 1ST FLOOR LEVEL,AND FRONT EXP#1 BUILDING WALL-OBSERVED STRUCTURE INSTALLED AT EXP#1 ON JOISTS/POSTS-UPPON ASKING F
#39549474N
Apr 1, 2026
IN VIOLATION
$2,500
Jan 23, 2026Construction CLASS - 2
OBSERVED SIDEWALK SHED INSTALLED AT EXP #1 WITH NO 5 FEET EXTENSION PROVIDED AT CORNER OF EXP#1/2(BC 3307.6.3),ADDITIONALLY OBSERVED BENDED BRACE,BENDED POST-CREATING PEDESTRIAN SAFETY FOR FALLING OBJECTS/COLLA
#39549475P
Apr 1, 2026
IN VIOLATION
$2,400
Jan 23, 2026Site Safety CLASS - 1
UPON CHECKING CONSTRUCTION SUPERINTENDED LOG BOOK -LAST RECORDED ENTRY OF BEING ON SITE/CHECKING THE SITE WAS ON-12/30/25- AND WORK BEING CONDUCTED CONTINUOUSLY AFTER 12/30/25-AS PER CODE IF CS WONT BE ON SITE
#39549476R
Oct 13, 2026
IN VIOLATION
$10,000
May 28, 2025Unknown CLASS - 2
AT THE TIME OF INSPECTION ON A NON ACTIVE JOB SITE, I OBSERVED SIDEWALK SHED ON PREMISES UPON MY REVIEW THROUGH DOB NOW AND BIS PERMIT # B00878258-I1-SH WAS EXPIRED SINCE 05-22-2024 AND NO NEW PERMIT WAS IN SY
#39540690R
Aug 6, 2025
IN VIOLATION
$1,250
May 23, 2024Unknown CLASS - 2
ATOI OBSERVED SWS IN PLACE AT EXPOSURE 1 OF PROPERTY, APPROX. 110 LINEAR FT IN LENGTH. SEARCH OF DEPT RECORDS INDICATES SWS PERMIT EXPIRED AS OF 05/22/2024. (PERMIT# B00878258-I1-SH) PERMIT MUST BE RENEWED AS P
#39115178K
Aug 7, 2024
DEFAULT
$3,125
May 22, 2024Construction CLASS - 2
ATOI OBSERVED APPROX 110 LINEAR FT SWS IN PLACE AT EXP 1. VERTICAL SUPPORTS @ PEDESTRIAN SIDEWALK COMPROMISED DUE TO MULTIPLE CRACKED/DAMAGED MUDSILLS. SHED MISSING HI-VIZ MARKINGS & SAFETY MEASURES AT ADJACENT
#39115042L
Aug 7, 2024
DEFAULT
$10,000
May 22, 2024Construction CLASS - 2
ATOI OBSERVED APPROX. 110 LINER FEAT SWS IN PLACE AT EXPOSURE 1. PERMIT NOT POSTED ON SITE AS PER CODE 28-105.11. PERMIT # B00878259-I1-SH, POST/PROPERLY POST PERMIT
#39115049Y
Aug 7, 2024
DEFAULT
$1,500
May 18, 2022Construction CLASS - 2
TEMPORARY EQUIPMENT ONSITE(SWS)-EXPIRED PERMIT OBSERVED SIDEWALK SHED STILL UP AT EXPOSURE#1.TEMPORARY CONSTRUCTION EQUIPMENT REQUIRES A PERMIT AT ALL TIMES TO REMAIN INSTALLED.PERMIT IN DOBNOW#B00536365 EXPIRE
#35586546K
Oct 12, 2022
DEFAULT
$6,250
DOB (1)
IssuedViolationStatus
May 8, 2026CONSTRUCTION
FAILURE TO COMPLY COMMISSIONER'S ORDER CONTAINED IN VIOLATION 041526CE30101ML (CONTROL 376486) ISSUED 4/15/2026. REMEDY: COMPLY WITH AFOREMENTIONED COMMISSIONER'S ORDER. PROVIDE ALL REQUESTED DOCUMENTS
#CE30101ML
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 8, 2026ECBUnknown: AT TIME OF INSPECTION OBSERVED: ACTIVE JOB SITE AT 3RD FLOOR LEVEL, STEEL COLUMN REACHED MORE THAN 40' HEIGHT APPROX. NO OVERHEAD PROTECTION FOR ADJOINING PROPERTIES AT EXPOSURE# 4 CREATING POTENTIAL SAFETY HAZOpen
Oct 8, 2026ECBUnknown: AT TIME OF INSPECTION OBSERVED: PROPOSED 4 STORY ALT. BUILDING AT 3RD FL. LEVEL. 10 FT. ABOVE ADJOINING PROPERTY. NO ROOF PROTECTION AT EXPOSURE# 4; CREATING AN UNSAFE HAZARDOUS CONDITION FOR ADJOINING OCCUPIEDOpen
Sep 29, 2026ECBUnknown: STOP ALL WORK UNDER #321184419. PRE-SHIFT MEETING LOG PROVIDED DOES NOT IDENTIFY SPECIFIC SAFETY CONCERNS/ RISKS ASSOCIATED WITH TASKS TO BE PERFORMED DURING THE SHIFT.MAINTAIN PRE-SHIFT MEETING LOGS WHICH INCLOpen
Sep 29, 2026ECBConstruction: OBSERVED STREET OPERATIONS/OCCUPANCY CONTRARY TO SITE SAFETY PLAN. NO ENCLOSURE USING YODOCK / JERSEY BARRIERS AROUND STAGING AREA AT EXPO 1. DUMPSTER/ MATERIAL RECEIVED PLACED ON STREET PRESENTING A HAZARD TOOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 10, 2026, 3:01 PM ET. BBL 3026290025.