4 floors · 184,328 sq ft · built 1966 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 184,328 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 796 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 269). Agency page | Dec 31, 2029 in 1161 days | Next due 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 8, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:THE CEILING IN THE GYM IS LEAKING WHENEVER IT RAINS.DAMAGE TO CEILING AND GYM FLOOR.ALSO EFFECTS ACTIVITIES IN THE GYM.REM:REPAIR LEAK/REPAIR DAMAGE. #35727373H | Aug 20, 2026 POP/IN-VIO | $0 |
| Jul 8, 2026 | Construction CLASS - 2 REISSUE#35724611K FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:THERE ARE CRACKS AT EXTERIOR FACADE.EXIT#2 AND 5 AND FLAKING OF MASONRY WAS NOTICED.REM:REPAIR/REPLACE. #35727372X | Aug 20, 2026 POP/IN-VIO | $0 |
| Aug 28, 2025 | Construction CLASS - 2 RE-ISSUE #35684816K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT VARIOUS LOCATIONS EXIT 5, 2, EXP. 1 AND 3 CRACKS AND FLAKING NEED REPAIR. REMEDY: REPAIR/REPLACE. #35724611K | Sep 10, 2025 POP/IN-VIO | $0 |
| Aug 27, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES FACADE DEFECTS NOTED AT EXIT#5 VERTICAL CRACK APPROX.8 FT ABOVE DOORS.EXIT#2 STEP CRACKAT GROUND LEVEL SOUTH ELEVATION.AT EXP#1 & 3(FRONT & REAR)SPALLING CON #35684816K | Nov 7, 2024 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Jul 8, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:THE CEILING IN THE GYM IS LEAKING WHENEVER IT RAINS.DAMAGE TO CEILING AND GYM FLOOR.ALSO EFFECTS ACTIVITIES IN THE GYM.REM:REPAIR LEAK/REPAIR DAMAGE. | Open |
| Jul 8, 2026 | ECB | Construction: REISSUE#35724611K FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:THERE ARE CRACKS AT EXTERIOR FACADE.EXIT#2 AND 5 AND FLAKING OF MASONRY WAS NOTICED.REM:REPAIR/REPLACE. | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 1:17 PM ET. BBL 1002690041.