Manhattan · Block 784 · Lot 12 · 10001

255 West 34 Street

32 floors · 157,517 sq ft · built 2021 · class H1 · owner of record: Penn District Hotel Llc

28open violations
$22,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
102dto Facade inspection report (Cycle 10A)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 102 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 157,517 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 171 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 171 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1146 days
Next cycle year 2029
Energy audit and retro-commissioning (2034) Likely applies
Local Law 87 · Calendar year 2034
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 784). Agency page

Dec 31, 2034
in 2972 days
Next due 2034

Open violations

ECB / OATH (9) · $22,500 owed
IssuedViolationHearingBalance
Sep 3, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED 4 ACTIVE SUSPENDED SCAFFOLDS. UPON INSPECTING SETUP OBSERVED A FRAMES INSTALLED SOME WITH WHEELS AND OTHERS WITH SCREW JACKS. I REQUEST TO SEE THE MANUFACTURE SPECS FOR THIS FRAME
#39558756X
Jan 7, 2027
$1,250
Sep 3, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED ACTIVE SUSPENDED SCAFFOLDS AT EXP. 1 AND 3. UPON REQUESTING RIGGING FOREMAN CARD TO DENNIS FERNANDO VIZUETE WHO INTRODUCE HIMSELF AS THE FOREMAN HE COULD NOT PRODUCE THE CARD. SC
#39558757H
Jan 7, 2027
PENDING
$1,250
Sep 3, 2026Unknown CLASS - 2
AT TIME OF INSPECTION OBSERVED 5 SUSPENDED SCAFFOLDS SETUPS AT EXP. 1 AND 3, 4 OF THEM ACTIVE. AS PER DOB RECORDS LAST NOTIFICATION WAS M01292613-I1 8739 CREATED ON 5-28-26 WHICH IS FOR THE REMOVAL OF SCAFFOLDS
#39558758J
Jan 7, 2027
PENDING
$5,000
Sep 3, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED 4 ACTIVE SUSPENDED SCAFFOLDS AT EXPOSURE 1 AND 3. UPON REVIEWING ALTREX SUSPENDED SCAFFOLDS MANUFACTURES SPECIFICATIONS IT SHOWS THAT PLATFORMS 6 METER AND BELOW SHALL NOT HAVE CA
#39558754M
Jan 7, 2027
$1,250
May 16, 2026Construction CLASS - 2
3301.7 OBSERVED SUSPENDED SCAFFOLD PLATFORM ASSEMBLED CONTRARY TO MANUFACTURER SPECIFICATIONS/DESIGN REQUIREMENTS. ALTREX PLATFORM CONFIGURATION AND GUARDRAIL SETUP NOT VERIFIED BY APPROVED MANUFACTURER DATA. R
#39554229X
Mar 25, 2027
$1,250
May 16, 2026Unknown CLASS - 1
3314.10.11 AT TIME OF INSPECTION, SUSPENDED SCAFFOLD AT EXPOSURE #1 OBSERVED NOT IN USE AND NOT LOWERED TO GROUND OR DECK AS REQUIRED. SCAFFOLD LEFT PARKED AT 33,FL ROOF DECK. NO DETAILS PROVIDED TO DEMONSTRATE
#39554228Y
Mar 25, 2027
$5,000
May 14, 2026Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENT. AS NOTED: AT TIME OF INSPECTION AT A JOBSITE OF A PROPOSED 36 STORY BUILDING ALREADY AT THE BULKHEAD LEVEL. OBSERVED FROM THE 1ST FLOOR EXPOSUR
#35726425X
Feb 5, 2027
$2,500
Dec 20, 2025Unknown CLASS - 2
AT TIME OF INSPECTION, A DELIVERY OPERATION WAS OBSERVED WITH FOUR WORKERS PRESENT. CONSTRUCTION MATERIALS WERE STORED ON THE SIDEWALK WITHIN THE PEDESTRIAN WALKWAY, CREATING AN UNSAFE CONDITION AND OBSTRUCTING
#39548201N
Mar 23, 2027
$2,500
Dec 20, 2025Unknown CLASS - 2
AT TIME OF INSPECTION AT A 36-STORY NB BUILDING, TWO WORKERS WERE OBSERVED PERFORMING LEADING-EDGE WORK WHILE PROPERLY TIED OFF; HOWEVER, NO REQUIRED CONTROLLED ACCESS ZONE WAS ESTABLISHED OR MAINTAINED. CONTRA
#39548200L
Mar 23, 2027
$2,500
DOB (8)
IssuedViolationStatus
Jun 10, 2015ELEVATOR
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTIO N/TEST
#VCAT100477
DOB VIOLATION - ACTIVE
Oct 31, 2014ELEVATOR
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTIO N/TEST
#VCAT100459
DOB VIOLATION - ACTIVE
Jun 24, 2014ELEVATOR

#9028/512368
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTIO N/TEST
#VCAT100769
DOB VIOLATION - ACTIVE
Feb 3, 2012ELEVATOR

#9028/419365
DOB VIOLATION - ACTIVE
Feb 4, 2011ELEVATOR

#9027/372974
DOB VIOLATION - ACTIVE
Nov 3, 2010ELEVATOR

#9027/362080
DOB VIOLATION - ACTIVE
Jan 30, 1997CONSTRUCTION

#05C14
VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE
DOB NOW Safety (18)
IssuedViolationStatus
Sep 25, 2026Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Jun 22, 2026Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 5)
Active
Aug 29, 2025Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Report
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Report
Active
May 20, 2019Elevators EVCAT5
Active
Apr 5, 2019Elevators EVCAT1
Active
Jun 10, 2015Elevators E
Active
Oct 31, 2014Elevators E
Active
Mar 31, 2014Elevators E
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 25, 2026DOB SafetyBenchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4Open
Sep 3, 2026ECBConstruction: AT TIME OF INSPECTION OBSERVED 4 ACTIVE SUSPENDED SCAFFOLDS. UPON INSPECTING SETUP OBSERVED A FRAMES INSTALLED SOME WITH WHEELS AND OTHERS WITH SCREW JACKS. I REQUEST TO SEE THE MANUFACTURE SPECS FOR THIS FRAMEClosed
Sep 3, 2026ECBConstruction: AT TIME OF INSPECTION OBSERVED ACTIVE SUSPENDED SCAFFOLDS AT EXP. 1 AND 3. UPON REQUESTING RIGGING FOREMAN CARD TO DENNIS FERNANDO VIZUETE WHO INTRODUCE HIMSELF AS THE FOREMAN HE COULD NOT PRODUCE THE CARD. SCOpen
Sep 3, 2026ECBUnknown: AT TIME OF INSPECTION OBSERVED 5 SUSPENDED SCAFFOLDS SETUPS AT EXP. 1 AND 3, 4 OF THEM ACTIVE. AS PER DOB RECORDS LAST NOTIFICATION WAS M01292613-I1 8739 CREATED ON 5-28-26 WHICH IS FOR THE REMOVAL OF SCAFFOLDSOpen
Sep 3, 2026ECBConstruction: UPON REVIEWING APPROVE PLANS NOTICE WORK NOT CONFORMING TO SETUP. DETAIL USE FOR DELTA OUTRIGGER BEAMS SHOWS CABLE TRUSS LABEL AS MAIN TENSION WIRE ROPE TO BE INSTALL. NONE OF THIS SETUPS HAVE TENSION WIRE INSTClosed
Sep 3, 2026ECBConstruction: AT TIME OF INSPECTION OBSERVED 4 ACTIVE SUSPENDED SCAFFOLDS AT EXPOSURE 1 AND 3. UPON REVIEWING ALTREX SUSPENDED SCAFFOLDS MANUFACTURES SPECIFICATIONS IT SHOWS THAT PLATFORMS 6 METER AND BELOW SHALL NOT HAVE CAClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 12:52 PM ET. BBL 1007840012.